Page 3 - CONTENTS
CONTENTS 2 EYEPIECES/FILAR MICROMETER EYEPIECE --------------------------------- 33 Widefield eyepieces WHN10x, WHN10x-H, CROSSWHN10x, WH15x --------------------- 33 Super widefield eyepieces SWH10x-H, MICROSWH10x, CROSSSWH10x ------------------------------ 33 Filar micrometer eyepiece U-OSM -------...
Page 4 - *In UIS2/UIS objective lenses, the parfocal distance is designed; Basic dimensions of UIS2/UIS optical system; *Coma aberration: refer to the optical terminology at the end of; Advantages of infinity-corrected optics; WELCOME TO UIS2/UIS OPTICS
light between the objective lens and tube lens, allowing the creation of user-specific or task- specific optical systems. To establish real flexibility with such a system, it is necessary to eliminate the occurrence of coma aberration. *In UIS2/UIS objective lenses, the parfocal distance is designed...
Page 5 - Features of UIS2 objective lenses; Wavefront aberration control; *Wave front aberration: refer to the optical terminology at the; Objective lenses with excellent image; * Refer to the Olympus home page for detailed
4. Lightening Weight has been reduced to approximately 2/3 that of conventional products by using an aluminum objective lens barrel cover. This has the effect of lightening the load on the devices at objective lens up/down, suppressing vibrations by lowering the inertial force at objective lens swit...
Page 6 - SYSTEM DIAGRAM; BXFM SYSTEM DIAGRAM
5 SYSTEM DIAGRAM 5 6 SHUTTER SHUTTER 5 6 SHUTTER U-AN U-AN360-3U-AN360IR LG-SF LG-PS2 U-LH100HGAPOU-LH100HG U-LH75XEAPO U-LH100-3U-LH100L-3U-LH100IR Super widefield trinocularobservation tubes Widefield trinocular observation tubes U-TLUU-TLUIR U-25ND6, U-25ND25, U-25LBD, U-25IF550, U-25L42, U-25FR,...
Page 7 - MOTORIZED UNIT SYSTEM DIAGRAM
6 SYSTEM DIAGRAM MOTORIZED UNIT SYSTEM DIAGRAM BXFM-A SYSTEM DIAGRAM See manual U-D5BDREMCU-D6BDREMC U-D6REMC U-FWO BX-RFAA U-AFA2M-VIS BX-RLAA U-LH100-3U-LH100L-3 U-FWR Intermediate tubes (Refer to pages 31-32) Observation tubes (Refer to pages 29-30) U-DICRHC U-DICR U-DICRH U-AN360-3 U-25ND6,U-25N...
Page 8 - UIS2/UIS OBJECTIVE LENSES; M P L; Objective lens series list
7 UIS2/UIS OBJECTIVE LENSES M P L (Plan) F L N - 1 0 0 B D ■ Objective lens series list ■ Meaning of abbreviations shown on objective lens ■ Objective lens notation ■ Features of objective lens series None: Brightfield BD: Brightfield/darkfield BDP: Brightfield/darkfield/ polarizing IR: IR LCD: LCD ...
Page 9 - UIS2 OBJECTIVE LENSES; Plan Apochromat; MPLAPON series
UIS2 OBJECTIVE LENSES 8 Plan Apochromat MPLAPON series Plan Apochromat objective lenses that correct chromatic aberrations at the highest level. Olympus guarantees* 1 optical performance (wavefront aberration) with a Strehl ratio* 2 of 95% or better. They are also designed for use with Olympus' U-AF...
Page 10 - M Plan SemiApochromat; MPLFLN series
UIS2 OBJECTIVE LENSES 9 M Plan SemiApochromat MPLFLN series Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. The lineup consists of 7 objective lenses ranging from 1.25x to 100x, and secures a W.D. of 1mm or longer. Since the exit pupil position of the 5x-...
Page 11 - Long WD M Plan SemiApochromat; LMPLFLN series; to be switched when changing the magnification.
10 UIS2 OBJECTIVE LENSES Long WD M Plan SemiApochromat (WD: Working Distance) LMPLFLN series Long working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. Suitable with samples having a height difference and in preventing collision, as the working...
Page 12 - M Plan Achromat; MPLN series
UIS2 OBJECTIVE LENSES 11 Unit: mm M Plan Achromat MPLN series Plan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5x 0.10 20.0 36 64 50 4.4 98 MPLN 10x 0.25 10.6 18 80 100 2.2 18 MPLN 20x 0.40 1.3 9 111 200 1.1 6.1 MPLN 50x 0.75 0.38 3.6 113 500 0.44 1.4 MPLN 100x 0...
Page 13 - LCD Long WD M Plan SemiApochromat
UIS2 OBJECTIVE LENSES 12 LCD Long WD M Plan SemiApochromat LCPLFLN-LCD series Perfect objective lens series for observation of LCD panels and other samples through a glass substrate. Aberration correction matched to the glass thickness is accomplished using a correction ring. Objective lens LCPLFLN2...
Page 14 - Super Long WD M Plan Achromat; SLMPLN series
13 UIS2 OBJECTIVE LENSES Unit: mm Super Long WD M Plan Achromat SLMPLN series Plan Achromat objective lenses with high magnification and super long working distance. Three magnifications, 20x, 50x and 100x are available. For 5x or 10x objective lenses, select from the LMPLFLN series. 19.3 19.8 (20) ...
Page 15 - UIS OBJECTIVE LENSES; IR Long WD M Plan Achromat/IR M Plan Achromat
UIS OBJECTIVE LENSES 14 IR Long WD M Plan Achromat/IR M Plan Achromat LMPlan-IR series/MPlan-IR IR objective lenses which compensate for aberrations from visible to near infrared light. Ideal for the observations of semiconductor interiors and the back surface of a chip package as well as CSP bump i...
Page 16 - M Plan SemiApochromat BD
15 UIS2 OBJECTIVE LENSES M Plan SemiApochromat BD (BD:Brightfield/Darkfield) MPLFLN-BD series Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. The series secures a W.D. of 1mm or longer. Since the exit pupil position of the 5x-150x objective lenses is stan...
Page 17 - M Plan SemiApochromat BDP
UIS2 OBJECTIVE LENSES 16 Screw: W26x0.706 Unit: mm MPLFLN 5xBDP 0.15 12.0 36 95.5 50 4.4 59 50 5.3 59 MPLFLN 10xBDP 0.25 6.5 18 83.3 100 2.2 18 100 2.7 18 MPLFLN 20xBDP 0.40 3.0 9 88.5 200 1.1 6.1 200 1.3 6.1 MPLFLN 50xBDP 0.75 1.0 3.6 100.5 500 0.44 1.4 500 0.53 1.4 MPLFLN 100xBDP 0.90 1.0 1.8 101....
Page 18 - Long WD M Plan SemiApochromat BD
UIS2 OBJECTIVE LENSES 17 Long WD M Plan SemiApochromat BD LMPLFLN-BD series Long working distance Plan SemiApochromat objective lenses, giving high-level correction for chromatic aberration. Suitable with samples having a height difference and in preventing collision, as the working distance is long...
Page 19 - M Plan Achromat BD
18 UIS2 OBJECTIVE LENSES M Plan Achromat BD MPLN-BD series Plan Achromat objective lenses providing excellent image flatness up to F.N. 22. MPLN 5xBD 0.10 12.0 36 137 50 4.4 98 MPLN 10xBD 0.25 6.5 18 155 100 2.2 18 MPLN 20xBD 0.40 1.3 9 162 200 1.1 6.1 MPLN 50xBD 0.75 0.38 3.6 157 500 0.44 1.4 MPLN ...
Page 20 - BXFM frame; MICROSCOPE SYSTEM BXFM
BXFM frame BXFM-F Widely used system that allows use in combination with fiber illumination, motorized revolving nosepiece and telan lens unit. Can easily be integrated into other equipment. Attach to the equipment by rear bolt mounting screw or pillar mounting hole. 19 MICROSCOPE SYSTEM BXFM Weight...
Page 21 - BXFM
MICROSCOPE SYSTEM BXFM 20 BXFM BXFM-F+BXFM-ILH+BXFM-ILHSPU Accommodates the reflected light brightfield/darkfield and fluorescence illuminators. Weight: 3.2kg Unit: mm 11 Light axis Light axis 165 130 83 45 40 72 23 7 3.5 Holder mounting position Pillar axis Revolving nosepiece mounting position Obj...
Page 23 - Stands
MICROSCOPE SYSTEM BXFM 22 U-ST Compact stand Weight: 5kg Unit: mm Weight: 1.8kg 106 73 143 88 ø110 133 ø32 49 133 20 35 ø40 130 503 ø25 Ø32 214~435 622 350 300 180º 90 50.5 30º 250 300 Stands A wide variety of stands are available to suit different applications and purposes. Item Specifications 1 Di...
Page 24 - ILLUMINATION UNITS; Universal reflected light illuminator
ILLUMINATION UNITS 23 Universal reflected light illuminator BX-URA2 Suitable for observations ranging from brightfield to fluorescence. Six mirror units can be attached to this reflected light illuminator simultaneously. Reflected light illuminator for BF/DF BX-RLA2 ND filters are linked when exchan...
Page 25 - Reflected light illuminators for BF
ILLUMINATION UNITS 24 170 (Distance to the light axis) Convex section(2-4) for positioning 3.5 Less than R6 21 82 (Revolving nosepiece relief dimension) 5 5.5 (6) (11) 2.5 52 (Revolving nosepiece relief dimension) 100 ( ± 0.1) 62 ( ± 0.1) 37 ± 0.1 (45 ° location face) Location face Location face 2 4...
Page 26 - LAMP HOUSING & ACCESSORIES; Reflected light illuminator for BF; Very compact reflected light illuminator with reduced depth.
LAMP HOUSING & ACCESSORIES 25 Reflected light illuminator for BF U-KMAS Very compact reflected light illuminator with reduced depth. Weight: 1.2kg Unit: mm ø75 88 198 155 21 64 6 21 Unit name Description Weight (g) U-25LBD LBD filter slider 20 U-25IF550 IF550 filter slider 20 U-25ND6 ND filter 2...
Page 27 - Lamp housings
LAMP HOUSING & ACCESSORIES 26 Lamp housings Various different lamp housings are available, for use with different light sources: choose to suit the intended purpose. * If you use the units in your production line, please consult your nearest Olympus representative in your region about the use co...
Page 28 - Lamp housing accessories
LAMP HOUSING & ACCESSORIES 27 31.5 (dimensions for installation) Darkfield light excluding tube which is built into the BX-URA2. (42.5) 21 37.5 ø59 ø75 43 Lamp housing accessories For the 100W halogen lamp, the external power supply TH4-100/200 with an intensity adjustment switch and an ON/OFF s...
Page 30 - OBSERVATION TUBES; Widefield trinocular observation tubes; Single port tube with lens; can be attached directly to the video port.
OBSERVATION TUBES 29 Weight: 350g ø60 56 • For attachable video camera adapters, refer to video camera adapters system diagram page (pages 5-6). U-TLU Single port tube with lens U-TLUIR Single port tube with lens for IR Widefield trinocular observation tubes Trinocular observation tubes with widefie...
Page 31 - Super widefield trinocular observation tubes
30 OBSERVATION TUBES 117.223 61.981 139.400 88.000 2.837 70.330 149.081 20 ° 0' 0" 42 ° 0' 0" 95.929 101.929 318.527 328.338337.718 72.200 Super widefield trinocular observation tubes Trinocular observation tubes with super widefield of view. Compatible with F.N. 26.5. 55.6 79.6 180.8 49.9 6...
Page 32 - Intermediate tubes; Various accessories for various observation need.; INTERMEDIATE TUBES & ACCESSORIES
Intermediate tubes Various accessories for various observation need. 31 INTERMEDIATE TUBES & ACCESSORIES 45 42 ø75 ø70 ø138 96 42 Unit: mm Weight: 1.3kg U-ECA Magnification changer 2x Provides 1x and 2x intermediate magnifications. Weight: 1.3kg U-CA Magnification changer Provides 1x, 1.2x, 1.6x...
Page 34 - Eyepieces; Eyepieces for UIS2 optical system.; Filar micrometer eyepiece; Used for precise measurement in the field of view.
EYEPIECES/FILAR MICROMETER EYEPIECE 33 Eyepieces Eyepieces for UIS2 optical system. Filar micrometer eyepiece U-OSM Used for precise measurement in the field of view. WHN10x Widefield eyepiece WHN10x-H CROSSWHN10x Widefield eyepieces WH15x Widefield eyepiece SWH10x-H MICROSWH10x CROSSSWH10x Super wi...
Page 35 - REVOLVING NOSEPIECES; Revolving nosepieces for BF objective lenses
REVOLVING NOSEPIECES U-P4RE Centerable quadruple revolving nosepiece with slider slot for DIC U-P6RE Centerable sextuple revolving nosepiece with slider slot for DIC Weight: 1kg Weight: 1kg 104 (114.4) 38 40 48.2 76.4 ø102.4 116.5 40 47.2 (125.6) 38 87.6 ø116.5 34 116.5 40 ø116.5 (125.6) 38 87.6 47....
Page 36 - Revolving nosepieces for BF/DF objective lenses; lenses. For motorized nosepieces, refer to motorized unit page.
REVOLVING NOSEPIECES JAPAN 2A00002 JAPAN U-D6BDREU-D6BDRE ø102.4 40 48.2 34.8 76.4 104 (111.2) 40 48.2 ø102.4 38 76.4 (114.4) 104 116.5 40 Ø116.5 (125.6) 38 87.6 47.2 U-D6BDRE W26 ✕ 0.706 W20.32 ✕ 0.706 (4) 4 8 ø28.2 +0.2 0 ø30 35 Revolving nosepieces for BF/DF objective lenses Choose from following...
Page 37 - C-mount video camera ports; All models feature a focus adjustment function; VIDEO CAMERA ADAPTERS
36 2/3" CCD 1/2" CCD Field of view (F.N.) Projection area Practical field of view (mm) = Projection area (Field Number) Objective lens magnifications 2/3" CCD 1/2" CCD 1/3" CCD U-TV1x-2 1x 11 8 6 U-TV0.63xC 0.63x 17.5 12.7 9.5 U-TV0.5xC-3 0.5x 22 16 12 U-TV0.35xC-2 0.35x — 22 17....
Page 38 - Video camera port; Video camera mount adapters
Video camera port This port can be attached directly to the trinocular observation tube as well as to the single port tube with lens. VIDEO CAMERA ADAPTERS 37 U-TV1x-2 Video port 1x 22 ø60 28 ø64 Video camera mount adapters Allows attachment to video cameras with C, Bayonet, Sony and F mounts. Use w...
Page 39 - MOTORIZED UNITS; Motorized units
MOTORIZED UNITS 38 (169) 84 40 45 41 87 (487) 400 64.8 81.5 211.5 86.2 115 80 108 11.8 12 107 Illuminator cable length: 1.800mm Weight: 5.5kg(exclude objective lens) Illuminator cable length: 1.800mm Weight: 4.3kg BX-RLAA+U-D6REMC+U-LH100-3 Motorized BF/DF reflected light illuminator+motorized Nomar...
Page 43 - DEEP ULTRAVIOLET OBSERVATION SYSTEM; Deep ultraviolet observation system
DEEP ULTRAVIOLET OBSERVATION SYSTEM 42 Deep ultraviolet observation system This module adds a deep ultraviolet (248nm) optical system to a general microscope. An ultra-high resolution observation is executed by using an extremely short wavelength ray. Unit: mm 108 258.5 69 79 ø8 (light guide) 34 30....
Page 44 - Total magnification for video monitor; Example; OPTICAL TERMINOLOGY
1. Field Number (F.N.) and Practical Field of View The field number (F.N.) is referred to as the diaphragm size ofeyepiece in mm unit which defines the image area of specimen.The diaphragm diameter actually seen through eyepiece isknown as the practical field of view (F.O.V.) which is determinedby t...
Page 45 - Resolving power formula; Focal depth of Microscope
• Total magnification on the video monitor: m (ob) =50 × , M (video camera adapter) is 0.5 × from Figure 1 and monitor magnification is 48.5 × from Figure 3. M (monitor observation) = M (ob) × M (video camera adapter) × monitor magnification =50 × 0.5 × 48.5=1213 × • Practical filed of view for vide...
Page 46 - Requirements for Ideal Image Formation; (i) All the light rays coming from a single point and passing; Classification of Aberrations
9. Aberrations A difference between an ideal image and an actual image thatpasses through an optical system is called an “aberration.” 9.1 Requirements for Ideal Image Formation The following three requirements must be satisfied to form animage with no aberration, or an ideal image. (i) All the ligh...
Page 47 - Wavefront Aberration
(4) Field curvature An image plane of an object on a plane perpendicular to anoptical axis does not always become a plane perpendicular tothe optical axis, but it generally becomes a curved plane. Thissymptom is called “field curvature.”When field curvature is present, the image is more displaced as...
Page 48 - Note) A laser interferometer is used for actual assessment of
47 OPTICAL TERMINOLOGY 9.4 Strehl ratio When a point light source is observed with an aberration-freeoptical system and an aberrated optical system , the formerconcentrates the focal point to a point at the image formationposition. In contrast, the latter fails to produce a focal point,instead causi...