Page 2 - IMPORTANT SAFETY INSTRUCTIONS; NOTE: Read all instructions before using this machine.
WARNING! To reduce the risk of fire, electric shock, or injury: • Do not leave the machine unattended when it is plugged-in. Unplug the unit from the power outlet when not in use. • Unplug the machine from the power outlet before cleaning or servicing.• Turn off all controls before unplugging.• To a...
Page 3 - Record the serial number and model of your new extractor here:
-3- 1 1 6 0 0 2 0 5 2 1 1 R E V A INSPECTION: Carefully unpack and inspect your HSC 585-MULTI for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should notify the carrier immediately if you notice damage t...
Page 4 - SWITCH PLATE; KNOW YOUR MACHINE
O I I I O O I I SWITCH PLATE 5 HIGH PRESSURE PUMP LIGHT (NO HEAT) DUMP PUMP ON/OFF SWITCH PUMP/HEAT SELECTOR SWITCH 100 PSI PUMP ON/OFF SWITCH 3 VACUUM ON/OFF SWITCH 2 4 HEAT SELECTED LIGHT KNOW YOUR MACHINE HSC 585 MULTI Switches 85 Bar Quick Disconnect Hoses Vacuum Hose Connection Base Compartment...
Page 5 - OPERATION; HIGH PRESSURE WASHER; CAUTION; : Never leave the 85 bar pump running if you are not actively using it
OPERATION REFER TO THE DIAGRAMS ON THE PREVIOUS PAGE HIGH PRESSURE WASHER 1 Before each use, inspect the machine, hoses, and cleaning tools for cleanliness and completeness. Makesure hoses are in good condition and the spray nozzle(s) is tight. REFER TO THE AUTO-FILL AND AUTO-DUMP INSTRUCTIONS ON TH...
Page 6 - LOW PRESSURE AND HEAT; sure hoses are in good condition and the spray nozzle(s) is tight.; continue on next page
water to a clear, solid stream. Priming may take 20 - 60 seconds, or even longer sometimes, and it will require a full solution tank. When the pump is primed, let off the Power Prime Pedal, and turn off thepump and the vacuum. Then press the Power Prime Pedal once again, for a moment, to release the...
Page 7 - LOW PRESSURE AND HEAT continued
3 . If you choose to use the auto-fill feature, connect the fill-hose to the hose connection over the solution tank fill hole. Turn on the water source, and allow the tank to fill with solution. NOTE: do not turn thewater on to full pressure; water flowing into the auto-fill system does not need a l...
Page 8 - AUTOMATIC-FILL INSTRUCTIONS
Operation:1. Attach a garden hose to the auto-fill hose connection above the holding tank fill hole, and connect the other end of the hose to your water source. 2. Make sure the float that hangs into the solution tank from the auto-fill valve is free of obstruction and can move freely. 3. Turn on th...
Page 9 - AUTOMATIC-DUMP INSTRUCTIONS
-9- 1 1 6 0 0 2 0 5 2 1 1 R E V A 1. Before each use: if necessary, unscrew the stainless steel filter inside the recovery tank and clean it. Also make sure the float in the recovery tank is clean. 2. Attach a garden hose to the automatic pump-out fitting on the back of the base of the machine (refe...
Page 11 - ALWAYS USE ONLY ORIGINAL NILFISK PARTS ON YOUR HSC 585 MULTI; PART LIST; ITEM QTY; MISCELLANEOUS PARTS AND KITS
ALWAYS USE ONLY ORIGINAL NILFISK PARTS ON YOUR HSC 585 MULTI HSC 585 MULTI PART LIST 220 - 240V 1 1 600758501 Reel with hoses, complete 2 1 600758502 Lid kit 3 1 600758503 Vacuum air inlet kit 4 1 600758504 Switch plate kit 5 1 600758505 Switch and light kit 6 1 600758506 Auto-fill kit 7 1 600758516...