Page 2 - PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE; INTRODUCTION; WARNING; CONTENTS; FUEL SUPPLY
PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE INTRODUCTION WARNING • The stove is an oil-fired stove. Do not bur n wood orother materials in this stove. • Adults and especially children should be aler ted to thehazards of high surface temperatures and should stayaway to avoid bur ns or clothing ign...
Page 3 - NAPOLEON OIL STOVE PRESIDENT’S LIFETIME LIMITED WARRANTY; CONDITIONS AND LIMITATIONS
NAPOLEON oil stoves are manufactured under the strict Standard of the World Recognized ISO9001 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete stove is thoroughly ins...
Page 4 - General information; Care of enamelled parts; DO NOT CLEAN GLASS WHEN HOT !; INSTALLATION; Unit and specifications; Figure 1
General information Nominal heat output Oil consumption ** Chimney draft required Weight Flue outlet inside diameter max speed min speed max speed min speed 27,300 BTU/hr .25 US gal/hr .073 US gal/hr .06" w.c. .024" w.c. 220 lbs 5 inches 8 kW 0.96 liter/h 0,28 liter/h 15 Pa 6 Pa 100 kg 125 m...
Page 5 - Figure 2
Location and clearances If the stove is to be installed on a combustible floor, it must be installed on sheet metal or a tile. The oil drip tray, 72636(not supplied) is a suitable substitute for either of these two pads. Maintain these minimum clearances to combustibles (fig. 2) : A 10 inches (250 m...
Page 6 - DO NOT INSTALL IN A ROOM USED FOR SLEEPING.; VENTING; Figure 3
INSTALLATION DO NOT INSTALL IN A ROOM USED FOR SLEEPING. The stove must be firmly bolted to the floor with 1/4 inch lag bolts (fig. 8, p. 8).Minimum clearances to combustibles are as shown in figure 2, page 5. VENTING The chimney must be installed in accordance with the manufacturer’sinstructions. U...
Page 7 - Chimney installation; MOBILE HOME INSTALLATION; Figure 5
There are two types of chimney connectors : A single wall chimney connector may be used for topconnection : This connector must be 316 grade 26 gauge stainless steel or 1 mmvitreous enamelled steel and with a 5" (127 mm) diameter. Securethe connector joints with 3 sheet metal screws. The joints ...
Page 8 - FINISHING; Mounting flue collar and blanking plate; Ash tray installation; angle, center onto tab ‘A’ and lower into place.; Figure 8
FINISHING Mounting flue collar and blanking plate The stove is supplied with a connection flue at top. The flue collar isreversible (2 screws) so that the smoke exit can be done at rear or on the top(figure 12 and figure 13, page 9). Leveling the stove Four adjusting bolts with caps are supplied and...
Page 10 - OPERATING INSTRUCTIONS; Understanding your oil stove; NEVER USE ALCOHOL OR GASOLINE AS A FIRESTARTER.; NEVER OPERATE THE STOVE WITH THE DOOR OPEN OR AJAR.
OPERATING INSTRUCTIONS Understanding your oil stove Furnace oil is fed from the tank to the burner floor (A) where isit ignited by means of a firestarter. The heat produced by thisflame brings the burner temperature to the required level tovaporize the fuel. Oil will only burn as a vapour not a liqu...
Page 11 - Shut down; Turn off the oil tank fuel supply valve.; ADJUSTMENTS; Oil flow adjustments; Adjustment at minimum speed :; Overheating
Shut down 1. Turn the control knob to “0" setting. 2. Lift the safety lever. 3. Turn off the oil tank fuel supply valve. The oil tank fuel supply valve should always be shut off whenthe oil stove is not in operation. ADJUSTMENTS Oil flow adjustments The oil flow s etting is done by the manufactu...
Page 12 - MAINTENANCE; Seasonal maintenance
MAINTENANCE Seasonal maintenance WEEKLY - DESCALE Push and pull the de-scaling lever in and out as well as turningslightly at the same time completely two or three times. Push in fornormal burner operations or before relighting. EVERY 3 TO 4 MONTHS - CLEAN BURNER R e m ov e a l l t h r e e c atalys ...
Page 13 - REPLACEMENTS; Ordering replacement parts; Installation date of fireplace; Replacement parts
REPLACEMENTS Ordering replacement parts Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all partscan be ordered through your Napoleon dealer or distributor. Whe n ordering replacement parts always give the followinginformation: 1. Model ...
Page 16 - TROUBLE SHOOTING
SYMPTOM PROBLEM TEST SOLUTION Flames extinguish during lighting. Very cold chimney. No draftestablished - Leave door ajar until fire has caught.- check air supply in the room Fire extinguishes once firestarter hasburnt off. Fuel tank is empty - Fill tank Fuel valve is closed. - Open valve Main carbu...