Page 2 - WHAT TO DO IF YOU SMELL GAS; WARNINGS & SAFETY PRECAUTIONS
2 W415-0559 / 02.15.06 WHAT TO DO IF YOU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier, call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas...
Page 3 - WARNING; TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
3 W415-0559 / 02.15.06 WARNING • Under no circumstances should this heater be modified.• Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the heater. Never obstruct the front opening of the heater.• If heater shuts off, do not re-l...
Page 5 - for use with other gases, unless a certified kit is used.; Use only accessories designed for and listed; American Nation Standards Institute Inc.; GENERAL INSTRUCTIONS
5 W415-0559 / 02.15.06 FOR YOUR SATISFACTION, THIS FIREPLACE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Maximum input is 23,000 BTU/hr for natural gas and propane. When the fi replace is installed at elevations above 2,000ft, and in the absence of specifi c recommendations from the local...
Page 6 - FIGURE 2; LOCATION & CLEARANCES; CARBON MONOXIDE POISONING MAY LEAD TO DEATH; Get fresh air at once! Have heater serviced.
6 W415-0559 / 02.15.06 MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 4" B. 2" * C. 2" Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stove. As long as clearan...
Page 7 - DO NOT KINK FLEXIBLE CONNECTOR.; Note: If replacing the pilot
7 W415-0559 / 02.15.06 BLOWER INSTALLATION GAS INSTALLATION 1. Install rigid black pipe, or 1/2" type L copper tubing with a shut-off valve to the stove. 2. Seal and tighten the gas line securely to a fl ex connector. DO NOT KINK FLEXIBLE CONNECTOR. 3. Check for gas leaks by brushing on a soap an...
Page 8 - FINISHING; CAST FRONT INSTALLATION; FRONT
8 W415-0559 / 02.15.06 FINISHING 1. Lift the top cast piece off of the unit. 2. Detach the front cast piece from the side pieces by remov- ing the screws from the brackets located in the upper inside corners. 3. Slide the front straight up to remove. CAST FRONT INSTALLATION AND REMOVAL 3 SCREWS BRAC...
Page 9 - LOG AND LOGO PLACEMENT; LOG PLACEMENT; LOGO PLACEMENT
9 W415-0559 / 02.15.06 3. Place the hole in the underside of log #3 onto the locating screw, on the right side of the burner. The bottom branch of log #3 sits infront of, and against, the right end of log #2.4. Reinstall the screen & front. LOG AND LOGO PLACEMENT In order to assemble the log set...
Page 10 - OXYGEN DEPLETION SENSOR; OPERATION; OPERATING INSTRUCTIONS
10 W415-0559 / 02.15.06 • Do not touch any electric switch; do not use any phone in your building.• Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.• If you cannot reach your gas supplier, call the fi re de- partment. When lighting and re-lighting, ...
Page 11 - ADJUSTMENTS; VENTURI ADJUSTMENT; an exact replacement.; OXYGEN DEPLETION SENSOR PILOT; MAINTENANCE
11 W415-0559 / 02.15.06 Air shutter adjustment must only be done by a qualifi ed gas installer! ADJUSTMENTS VENTURI ADJUSTMENT 1 . In order to properly clean the burner and pilot assembly, remove the logs exposing both assemblies. 2 . Keep the control compartment, logs, burner, air shutter opening an...
Page 12 - REPLACEMENTS; REPLACEMENT PARTS
12 W415-0559 / 02.15.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. M ODEL & S ERIAL N UMBER OF ...
Page 14 - TROUBLE SHOOTING GUIDE; SYMPTOM
14 W415-0559 / 02.15.06 Main burner goes out; pilot stays on. Pilot fl ame is not large enough or not engulfi ng the thermo-pile - service or replace Oxygen Depletion Sensor System- correct piping and/or regulator to provide correct pressure Thermopile shorting - clean thermopile connection to the val...
Page 16 - Fireplace Service History; This fireplace must be serviced annually depending on usage; NOTES
16 W415-0559 / 02.15.06 Fireplace Service History This fireplace must be serviced annually depending on usage DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS NOTES