2 W415-0171 / D / 01.06.04 10-11 OPERATION / MAINTENANCE Operating InstructionsFresh Air Damper SystemMaintenance 11 BLOWER INSTALLATION Blower Replacement Instructions 11 ADJUSTMENTS Venturi AdjustmentsPilot Burner Adjustment 12-13 REPLACEMENTS Ordering Replacement PartsReplacement PartsAccessories...
Page 4 - GENERAL INSTRUCTIONS; FIGURE 1
4 W415-0171 / D / 01.06.04 The fireplace, when installed, must be electrically con-nected and grounded in accordance with local codes. Inthe absence of local codes, use the current CSA C22.1C A N A D I A N E L E C T R I C A L C O D E i n C a n a d a o r t h eANSI/NFPA 70 NATIONAL ELECTRICAL CODE in ...
Page 5 - WIRE SIZE; CARE OF GLASS, ENAMELLED AND PLATED PARTS; INSTALLATION; FIGURE 3
5 W415-0171 / D / 01.06.04 Do not use abrasive cleaners to clean these parts. Bufflightly with a clean dry cloth. Porcelain enamelled compo-nents must be handled with care. The baked-on finish isglasslike. If struck, it will chip! Touch-up paint is availablethrough your Napoleon dealer. Levelling th...
Page 6 - FIGURE 9a; SPILL SWITCH; FINISHING; OPTIONAL BRICK PANEL INSTALLATION
6 W415-0171 / D / 01.06.04 R e m o v e t h e s e -curing screws lo-cated on either oft h e f i r e b o x s i d e sa s i l l u s t r a t e d .Remove protectiveplastic wrap froma l l f o u r p a n e l s .C e n t r e t h e r e a rb r i c k p a n e lagainst the back ofthe firebox. Placethe left brick pa...
Page 7 - LOG PLACEMENT
7 W415-0171 / D / 01.06.04 FIGURE 10 FIGURE 11 POSITIONING THE LOGS IMPROPERLY WILL CAUSE FLAME IMPINGEMENT AND CARBONING. PHAZER TM logs and charcoal embers, exclusive to Napo- leon Fireplaces, provide a unique and realistic glowingeffect that is different in every installation. Take the time tocar...
Page 8 - LOGO PLACEMENT; UPPER LOUVRES
8 W415-0171 / D / 01.06.04 Attach the lower glass bracket.Seat the glass inside the bracketand using two screws attach theupper glass bracket, as shown. Assemble the flashing and mount to the inside of the outershell using 4 securing screws (supplied with the louvrekit). Remove the backing of the lo...
Page 10 - Turn the gas knob counter-clockwise to; OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS
10 W415-0171 / D / 01.06.04 If your masonry fireplace is equipped with a fresh air inletin the floor of the firebrick chamber, the insert is able totake outside air directly into the unit through an opening inits base thereby eliminating the need to use preheatedroom air for combustion. The flow of ...
Page 11 - AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A; MAINTENANCE; BLOWER REPLACEMENT INSTALLATION; BLOWER SYSTEM; BLOWER REPLACEMENT INSTRUCTIONS; ADJUSTMENTS; PILOT BURNER ADJUSTMENT
11 W415-0171 / D / 01.06.04 3. Check to see that all burner ports are burning. Clean outany of the ports which may not be burning or are not burn-ing properly. (right brick panel must be removed in order tofacilitate burner removal) 4. Check to see that the pilot flame is large enough toengulf the t...
Page 12 - REPLACEMENTS; REPLACEMENT PARTS
12 W415-0171 / D / 01.06.04 # PART NO. DESCRIPTION 1 GZ-551 REPLACEMENT BLOWER 2 W725-0036 NATURAL GAS VALVE C/W ADJUSTABLE REGULATOR 2 W725-0037 PROPANE GAS VALVE C/W ADJUSTABLE REGULATOR 3 W455-0004 #36 DMS NATURAL GAS BURNER ORIFICE 3 W455-0003 #54 DMS PROPANE GAS BURNER ORIFICE 3 W455-0013 #37 D...
Page 14 - A - Wall switch is defective; A - No spark at pilot burner; TROUBLE SHOOTING GUIDE; SYMPTOM
14 W415-0171 / D / 01.06.04 Gas piping is undersized. P i l o t g o e s o u t w h i l estanding; Main burneris in 'OFF' position. - turn on all gas appliances and see if pilot flame flutters,diminishes or extinguishes, especially when main burnersignite. Monitor supply pressure.- check if supply pip...
Page 15 - C - Chimney is blocked
15 W415-0171 / D / 01.06.04 Main burner goes out;pilot goes out. A - Refer to "Main burner goes out; pilot stays on" B - Chimney down-drafting - wait ten minutes. Shut off all exhaust fans in the house(ie: kitchen and bathrooms), furnace, and clothes dryer.Open windows and/or doors. Start fi...
Page 16 - Wolf Steel Fireplace Service History; This fireplace must be serviced annually depending on usage.
16 W415-0171 / D / 01.06.04 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Date Service Technician Name Service Performed Special Concerns Dealer Name