Page 2 - TABLE of CONTENTS; RETAIN THIS MANUAL FOR FUTURE REFERENCE; INSTALLATION; REPLACEMENT; WARNING
2 W415-0607 / A / 01.18.08 • Do not burn wood or other materials in this stove.• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the stove...
Page 4 - GENERAL INSTRUCTIONS
4 W415-0607 / A / 01.18.08 FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inches water column for natural gas and 11 inches water column for propane. Maximum inlet gas pressure is 7 inches water column for natural g...
Page 5 - DIMENSIONS; VENTING; VENTING LENGTHS AND AIR TERMINAL LOCATIONS; VENT INSTALLATIONS
5 W415-0607 / A / 01.18.08 35 1 / 2 ” 37” 18 1 / 8 ” 23 5 / 8 ” 4” DIA. 7” DIA. GASLINEACCESS ELECTRICAL ACCESS 29 1 / 8 ” DIMENSIONS FIGURE 1a VENTING VENTING LENGTHS AND AIR TERMINAL LOCATIONS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting component...
Page 6 - TYPICAL VENT INSTALLATIONS; CORNER TERMINATION; SPECIAL VENT INSTALLATIONS; PERISCOPE TERMINATION
6 W415-0607 / A / 01.18.08 16” MINIMUM 40 FT MAXIMUM 3 FT MINIMUM 16” MINIMUM 40 FT MAXIMUM 3 FT MINIMUM TYPICAL VENT INSTALLATIONS FIGURE 2a FIGURE 3a * Refer to "Venting" Section The maximum vent length for a corner installation is 20" of horizontal run, in addition to the 45° offset. ...
Page 7 - MINIMUM AIR TERMINAL LOCATION CLEARANCES
7 W415-0607 / A / 01.18.08 FIGURE 6 MINIMUM AIR TERMINAL LOCATION CLEARANCES
Page 9 - DEFINITIONS; TOP EXIT / HORIZONTAL TERMINATION
9 W415-0607 / A / 01.18.08 90° 90° 90° H 1 V 2 H 2 V 1 Simple venting con fi guration (only one 90° elbow) For vent con fi gurations requiring more than one 90° elbow, the following formulas apply: Formula 1: H T < V T Formula 2: H T + V T < 40 feet Example 1: V 1 = 3 ft V 2 = 8 ft V T = V 1 +...
Page 11 - REAR EXIT / HORIZONTAL TERMINATION
11 W415-0607 / A / 01.18.08 See graph to determine the required vertical rise V T for the required horizontal run H T For vent con fi gurations requiring more than two 90° elbows the following formulas apply: Formula 1: H T < V T Formula 2: H T + V T < 40 feet HORIZONTAL VENT RUN PLUS OFFSETS ...
Page 13 - TOP OR REAR EXIT VERTICAL TERMINATION
13 W415-0607 / A / 01.18.08 REQUIRED VERTICAL RISE IN FEET V T HORIZONTAL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . Example 6: V 1 = 5 ft V 2 = 6 ft V 3 = 10 ft V T = V 1 + V 2 + V 3 = 5 + 6 + 10 = 21 ft H 1 = 8 ft H 2 = 2.5 ft H...
Page 14 - VERTICAL THROUGH EXISTING CHIMNEY
14 W415-0607 / A / 01.18.08 VERTICAL THROUGH EXISTING CHIMNEY This appliance is designed to be attached to a 3" co-linear fl exible vent system running the full length of a masonry chimney. The fl exible vent pipe accommodates any contours of a masonry chimney, however, it is necessary to keep t...
Page 15 - REAR EXIT CONVERSION
15 W415-0607 / A / 01.18.08 REAR EXIT CONVERSION FIGURE 19 4” Gasket 7” Cover Plate 7” Gasket 4” Gasket 4” Collar 7” Gasket 7” Collar Outer Top 4” Cover Plate In order to convert the venting con fi guration from a top exit to a rear exit , remove components as illustrated: When reinstalling in the a...
Page 16 - HORIZONTAL INSTALLATION; VENT PIPE
16 W415-0607 / A / 01.18.08 1. Determine the air terminal location, cut and frame a 9" square opening in the ceiling and the roof to provide the minimum 1" clearance between the vent pipe / liner and any combustible material. Try to center the vent pipe location midway between two joists to ...
Page 17 - STOVE VENT CONNECTION; HORIZONTAL VENTING INSTALLATION
17 W415-0607 / A / 01.18.08 SCREWS & WASHERS 4" COUPLER SELF DRILLING #8x1/2" 7" RIGID VENTPIPE SEALANT HIGH TEMPERATURE 4" FLEXIBLE VENT PIPE 7" RIGID VENT PIPE 1. Attach the telescopic sleeve to the last section of 7" rigid vent pipe. Secure with screws and high tempera...
Page 18 - RESTRICTING VERTICAL VENTS; VERTICAL VENTING INSTALLATION
18 W415-0607 / A / 01.18.08 RESTRICTING VERTICAL VENTS Vertical termination installations exiting either from the rear or the top flue collar of the stove may display a very active flame. If this appearance is not desirable, the vent exit must be restricted to reduce the velocity of the exhaust gase...
Page 19 - GAS INSTALLATION
19 W415-0607 / A / 01.18.08 FIGURE 30 FIGURE 31 R E S T R I C T O R PLATE 1. Remove the front and the door from the stove. 2. Remove the screws securing the baf fl e plate. Figure 31 . Note: The baf fl e rests on two screws that are attached to the back of the fi rebox. 3. Using the screws supplied,...
Page 20 - MINIMUM MANTEL, SHELF OR CEILING CLEARANCES; REAR EXIT; MINIMUM CLEARANCES TO COMBUSTIBLES; BACK WALL SIDE W
20 W415-0607 / A / 01.18.08 FIGURE 34 MINIMUM MANTEL, SHELF OR CEILING CLEARANCES 1” 2” 47 1 / 2 ” 35 1 / 2 ” 5” BRICK COMBUSTIBLE NON-COMBUSTIBLE 29 1 / 8 ” MINIMUM PLUS RISE * 0” IF NON-COMBUSTIBLEFINISHING IS USEDSUCH AS BRICK AND STONE. 12” MANTEL, SHELF, OR CEILING REAR EXIT TOP EXIT * HORIZONT...
Page 21 - BLOWER INSTALLATION; NIGHT LIGHT; LENS ASSEMBLY INSTALLATION; THE FIREBOX MUST BE SEALED.; BULB REPLACEMENT
21 W415-0607 / A / 01.18.08 BLOWER INSTALLATION ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the current ANSI/NFPA 70 NATIO...
Page 22 - FINISHING; GLASS DOOR INSTALLATION AND REMOVAL; DOOR GLASS REPLACEMENT; GLASS
22 W415-0607 / A / 01.18.08 90° FINISHING GLASS DOOR INSTALLATION AND REMOVAL 1. Lift the top cast piece off of the unit. 2. Pull handle forward and rotate 90º to unlatch the door. Figure 41a. 3. Lift door straight up to remove. Figure 41b. FIGURE41a LOGO PLACEMENT LOGO 1/2” 1/2” Remove the backing ...
Page 23 - TOP VIEW
23 W415-0607 / A / 01.18.08 1. Place the rear log as shown, ensuring the holes on the underside are placed onto the 2 pins of the log support. In order to assemble the log set, the glass door must be removed, see Glass Door Installation and Removal in the FINISHING section of this manual. LOG PLACEM...
Page 24 - * See detail for optional; WIRING DIAGRAM
24 W415-0607 / A / 01.18.08 FIGURE 46 B ATTERY H OLDER G AS V ALVE P ILOT A SSEMBLY I GNITION M ODULE P ILOT G AS L INE Orange (I) [through independent conduit] Yellow (S) [throughGas line conduit] AC A DAPTOR B ATTERY R ELAY Red (3 Volt) Red Black W IRE H ARNESS N OTE : W IRE TAGS ARE BRACKETED Bro...
Page 25 - TO TURN OFF GAS; OPERATING INSTRUCTIONS; OPERATION / MAINTENANCE; MAINTENANCE
25 W415-0607 / A / 01.18.08 1. STOP! READ THE ABOVE SAFETY INFORMATION ON THIS LABEL. 2. TURN REMOTE WALL SWITCH TO OFF POSITION.3. TURN OFF ALL ELECTRIC POWER TO THE STOVE AND REMOVE BATTERIES.4. THIS STOVE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TRY TO LIGH...
Page 26 - ADJUSTMENTS; PILOT INJECTOR AND ORIFICE REPLACEMENT; FLAME ADJUSTMENT AND CHARACTERISTICS
26 W415-0607 / A / 01.18.08 NOTE: Check and adjust, if necessary, the primary air to 7 / 16 ” for propane and 1 / 4 ” for natural gas. Replace the screws. 7. Turn on the gas supply and check for gas leaks by brushing on a soap and water solution. Do not use open fl ame. 8. Replace the log set. Then ...
Page 27 - REPLACEMENTS; REPLACEMENT PARTS
27 W415-0607 / A / 01.18.08 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon® dealer or distributor. When ordering replacement parts always give the following information:1. M ODEL & S ERIAL N UMBER...
Page 29 - TROUBLE SHOOTING GUIDE; SYMPTOM
29 W415-0607 / A / 01.18.08 Pilot will not light. Verify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly.Verify no loose connections, electrical shorts in the wiring or ground out to an...
Page 31 - This fireplace must be serviced annually depending on usage.
31 W415-0607 / A / 01.18.08 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed S pecial Concerns Dealer Name