Page 2 - WHAT TO DO IF YOU SMELL GAS; WARNINGS & SAFETY PRECAUTIONS
2 W415-0547 / C / 07.25.06 WHAT TO DO IF YOU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier, call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbour's phone. Follow th...
Page 3 - TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
3 W415-0547 / C / 07.25.06 WARNING • The stove is a vented gas-fi red heater. Do not burn wood or other materials in this stove.• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children...
Page 5 - GENERAL INSTRUCTIONS
5 W415-0547 / C / 07.25.06 The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not be removed from the cord plug. FOR YOUR SATISFACTION, THIS STOVE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND QUALITY! Minimum inlet gas supply pressure is 4.5 inch...
Page 6 - MAINTAIN THESE MINIMUM CLEARANCES; HORIZONTAL VENT; Provide adequate accessibility clearance for; FIGURE 2; LOCATION & CLEARANCES; STOVE DIMENSIONS; FIGURE 1; MANTEL OR SHELF CLEARANCES:
6 W415-0547 / C / 07.25.06 MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 4" B. 2" * C. 2" STOVE SHOULD NOT BE INSTALLED DIRECTLY ON CARPETING . TO CEILING FROM STOVE TOP ..................................................48" HORIZONTAL VENT SIDES AND BOTTOM ......................
Page 7 - BLOWER INSTALLATION; THE FIREBOX; NIGHT LIGHT REPLACEMENT
7 W415-0547 / C / 07.25.06 BLOWER INSTALLATION 4 5 8 2 3 1 9 7 7 4 Blower ( SEE LOCATION AND CLEARANCES ) 1. Cut and remove the tie securing the blower switch wires to the heat shield. 2. Connect the white wire coming from below the unit to the terminal on the blower. 3. Connect the black blower wir...
Page 8 - non; CANADIAN; INSTALLATIONS; AIR TERMINAL LOCATIONS
8 W415-0547 / C / 07.25.06 ***** Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** It is recommended to use a heat shield and to maximize the distance to vinyl clad soffits. *** *** *** *** *** The periscope GD-201 requires a minimum 18 inches clearance from an insid...
Page 9 - FIGURE 5; VENTING; mended that all horizontal runs have a; FIGURE 4; TYPICAL CORNER INSTALL
9 W415-0547 / C / 07.25.06 Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components. For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure provided with the venting components. All outer pipe joint...
Page 10 - TYPICAL VENT INSTALLATIONS; When terminating vertically above 15', the
10 W415-0547 / C / 07.25.06 USE GD201 PERISCOPE KIT BELOW GRADE INSTALLATION MAXIMUM 10FT VENT LENGTH OF HORIZONTAL REGARDLESS VENT LENGTH 24" MINIMUM 12"MINIMUM Use the GD201 periscope kit to locate the air termination above grade. The periscope must be installed so that when fi nal grading...
Page 11 - HORIZONTAL TERMINATION
11 W415-0547 / C / 07.25.06 ELBOW VENT LENGTH VALUES DEFINITIONS HORIZONTAL TERMINATION 0 2.5 5 7.5 10 12.5 15 40 10 20 30 17.5 20 39 REQUIREDV E R T I C A L R I S E I N FEET (V T ) CALCULATED HORIZONTAL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) f...
Page 12 - FIGURE 7; FIGURE 8
12 W415-0547 / C / 07.25.06 V 1 HORIZONTAL TERMINATION 20 10 0 5 10 15 90 100 120 110 30 40 50 60 70 80 130 140 150 20 S e e g r a p h t o d e t e r m i n e the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 45º and 90° elbow the fol...
Page 13 - VERTICAL TERMINATION; FIGURE 9
13 W415-0547 / C / 07.25.06 VERTICAL TERMINATION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T...
Page 14 - unacceptable
14 W415-0547 / C / 07.25.06 H 1 VERTICAL TERMINATION 0 5 10 15 20 10 20 3 25 30 19 Formula 1: H T < 3V T Formula 2: H T + V T < 40 feet Example 4: V 1 = 1 ft when (H T ) > (V T ) Simple venting confi gurationsSee graph to determine the required vertical rise V T for the required horizontal ...
Page 15 - VERTICAL THROUGH EXISTING CHIMNEY; INSTALLATION
15 W415-0547 / C / 07.25.06 VERTICAL THROUGH EXISTING CHIMNEY This appliance is designed to be attached to a 3" co-lin-ear aluminum fl ex vent system running the full length of a masonry chimney. The fl exliner accommdates any contours of a masonrychimney, however, it is necessary to keep the fl...
Page 16 - HORIZONTAL INSTALLATION; FOR SAFE AND PROPER; VENT PIPE; VERTICAL INSTALLATION; WALL AND CEILING PROTECTION
16 W415-0547 / C / 07.25.06 This application occurs when venting through an exterior wall. Having determined the air terminal location, cut and frame a hole in an exterior wall with a minimum rectangle opening of 10" x 9". I M P O RTA N T: F O R O P T I M U M P E R F O R M A N C E , T H E ST...
Page 17 - VERTICAL VENTING INSTALLATION; HORIZONTAL VENTING INSTALLATION; DO NOT CLAMP
17 W415-0547 / C / 07.25.06 1. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support. 2. Stretch t...
Page 18 - STOVE VENT CONNECTION; GAS INSTALLATION
18 W415-0547 / C / 07.25.06 1. Attach the adjustable pipe to the last section of rigid pip- ing. Secure with screws and seal. 2. Install the 4" aluminium fl exible liner to the stove. Secure with 3 screws and fl at washers. Seal the joint and screw holes using high temperature sealant. 3. Run a ...
Page 19 - FINISHING; GLASS DOOR INSTALLATION; SWITCH FUNCTIONS
19 W415-0547 / C / 07.25.06 FINISHING GLASS DOOR INSTALLATION AND REMOVAL CAST FRONT INSTALLATION AND REMOVAL FRONT SCREWS BRACKET 3 2 Follow the above steps in reverse in order to reinstall the door. Ensure that the bottom of the door meets the door retainer before closing the latches. Follow the a...
Page 20 - LOG LOCATING SCREWS; BRACKET
20 W415-0547 / C / 07.25.06 LOG PLACEMENT LOGO PLACEMENT LOGO 1.27cm 1.27cm Remove the backing from the the logo and position onto the control door as shown. It is not necessary to remove the cast front, however, this will make for a more simple log installation. In order to assemble the log set, th...
Page 21 - OPTIONAL SWITCH / WIRING DIAGRAM; WIRE SIZE
21 W415-0547 / C / 07.25.06 OPTIONAL SWITCH / WIRING DIAGRAM The on/off switch is located on the back of the GDS25 at the top right corner. For ease of acces-sibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. The recommended maximum lead lengt...
Page 22 - TO TURN OFF GAS; OPERATING INSTRUCTIONS
22 W415-0547 / C / 07.25.06 1. STOP! READ THE ABOVE SAFETY INFORMATION ON THIS LABEL. 2. TURN REMOTE WALL SWITCH TO OFF POSITION.3. TURN OFF ALL ELECTRIC POWER TO THE FIREPLACE AND REMOVE BATTERIES. 4. THIS FIREPLACE IS EQUIPPED WITH AN IGNITION DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT. DO NOT TR...
Page 23 - Air shutter adjustment must only be done by a; ADJUSTMENTS; PILOT INJECTOR AND ORIFICE REPLACEMENT; TURN OFF THE GAS AND UNPLUG; MAINTENANCE
23 W415-0547 / C / 07.25.06 NOTE: Check and adjust, if necessary, the primary air to 7 / 16 ” for propane and 1 / 4 ” for natural gas. Replace the screws. 7. Turn on the gas supply and check for gas leaks by brushing on a soap and water solution. Do not use open fl ame. 8. Replace the log set. Then ...
Page 24 - REPLACEMENTS; REPLACEMENT PARTS
24 W415-0547 / C / 07.25.06 Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ordered through your Napoleon dealer or distributor. When ordering replacement parts always give the following information: 1. M ODEL & S ERIAL N UMBER...
Page 26 - TROUBLE SHOOTING GUIDE; SYMPTOM
26 W415-0547 / C / 07.25.06 Pilot will not light. Verify the "S" wire for the sensor and the "I" wire for the ignitor are connected to the correct terminals (not reverse) on the module and pilot assembly.Verify no loose connections, electrical shorts in the wiring or ground out to an...
Page 28 - Fireplace Service History; This fireplace must be serviced annually depending on usage
28 W415-0547 / C / 07.25.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SER VICE TECHNICIAN NAME SER VICE PERFORMANCE SPECIAL CONCERNS