Page 2 - M O D E L G D S 2 8; TABLE OF CONTENTS; be done by a licensed or qualified service person.
2 W415-0153 / A / 10.29.01 PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE Pg 13 GAS INSTALLATION Remote Wall Switch / Thermostat 14 FINISHING Door Closing & OpeningLog Placement 15-16 OPERATION / MAINTENANCE Spill SwitchVenting Action CheckOperating InstructionsMaintenance 17 REPLACEMENT BLOWER ...
Page 4 - Do not substitute materials.; GENERAL INSTRUCTIONS
4 W415-0153 / A / 10.29.01 GENERAL INFORMATION For your satisfaction, this stove has been test-firedto assure its operation and quality! Minimum inlet gas supply pressure is 4.5 inches watercolumn for natural gas and 11 inches water column forpropane. Maximum inlet gas pressure is 7 inches watercolu...
Page 5 - MAINTAIN THESE MINIMUM CLEARANCES TO; LOCATION AND CLEARANCES; FIGURE 2; VENTING LENGTHS AND AIR TERMI-; WALL TERMINAL KIT GD175; STOVE PERISCOPE; DIRECT VENT SPECIFICS - GDS28; FIGURE 1
5 W415-0153 / A / 10.29.01 MAINTAIN THESE MINIMUM CLEARANCES TO COMBUSTIBLES: A. 7" D. 14 3 / 4 " B. 2" E. 4" C. 1" * F. 9½" N O ADDITIONAL FLOOR PROTECTION IS REQUIRED MINIMUM 20" FROM STOVE TOP TO CEILING * AT A DISTANCE OF 1" FROM THE WALL , ACCESS TO THE BLOWER SW...
Page 6 - SPECIAL INSTALLATION EXAMPLE; OFFSET INSTALLATION EXAMPLE; FIGURE 4; first run of 72 inches; FIGURE 6; Do not include the first elbow directly off the unit.
6 W415-0153 / A / 10.29.01 HORIZONTAL RUN NOT TO EXCEED VERTICAL RISE SPECIAL INSTALLATION EXAMPLE When a horizontal offset is required in a through-the-roofinstallation, the following procedure for vent length calcula-tions must be followed: In an installation as shown in FIGURE 7, lengths A and C ...
Page 7 - non; CANADIAN; INSTALLATIONS
7 W415-0153 / A / 10.29.01 FIGURE 10 AIR AIR AIR AIR AIR TERMIN TERMIN TERMIN TERMIN TERMINAL INST AL INST AL INST AL INST AL INSTALLA ALLA ALLA ALLA ALLATIONS: TIONS: TIONS: TIONS: TIONS: ***** Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** It is recommended to u...
Page 8 - VERTICAL INSTALLATION:; VENT; F I G U R E S; OR; WALL AND CEILING PROTECTION
8 W415-0153 / A / 10.29.01 VERTICAL INSTALLATION: This application occurs when venting through a roof. FIGURE 3. Installation kits for vari-o u s r o o f p i t c h e s a r eavailable from your Na-poleon dealer. See Ac-cessories to order thespecific kit required. 1. Determine the air terminal locatio...
Page 9 - VERTICAL VENTING INSTALLATION; HORIZONTAL VENTING INSTALLATION
9 W415-0153 / A / 10.29.01 VERTICAL VENTING INSTALLATION 1 . F a s t e n t h e r o o f support to the roof us-i n g t h e s c r e w s p r o -vided. The roof supportis optional. In this casethe venting is to be ad-e q u a t e l y s u p p o r t e dusing either an alter-nate method suitableto the autho...
Page 10 - SPEED SWITCH
10 W415-0153 / A / 10.29.01 Ensure that the sealant is not visible on the exte-rior pipes once installation is completed. An op-tional decorative brass band is available for thisuse. (Standard with a GD175 kit). In the event thatthe venting must be disassembled, care must betaken to reseal the venti...
Page 11 - ADAPTER INSTALLATION; To pass the wires through
11 W415-0153 / A / 10.29.01 COMBUSTION AIR COVER PLATES & GASKETS I N S T I N S T I N S T I N S T I N S TA L L I N G ' B ' A L L I N G ' B ' A L L I N G ' B ' A L L I N G ' B ' A L L I N G ' B ' V E N T V E N T V E N T V E N T V E N T ::::: Follow the instructions for " Wall and Ceiling Prot...
Page 12 - COMBUSTION AIR; INSTALLING FLASHING AND STORM
12 W415-0153 / A / 10.29.01 For aesthetics, the adapter has been designed to accepta standard matte black 7" stove pipe and the Napoleondecorative brass band (standard with the GS-150KT). Bothare available from your Napoleon dealer. B-VENT MODEL GS28 ONLY: Attach the B-Vent label, shown below, i...
Page 13 - Mark the appropriate boxes; DO NOT KINK FLEXIBLE CONNECTOR.; GA S INSTALL ATION; DO NOT USE OPEN FLAME.
13 W415-0153 / A / 10.29.01 Mark the appropriate boxes on the rating plate label to indi- cate the model type depending on the installation (directvent or B-vent). Read the section on opening the door in "Finishing" priorto proceeding to prevent damaging the unit. Bring the gas line to the s...
Page 14 - DOOR CLOSING AND OPENING; F I N I S H I N G; LOG PLACEMENT INSTRUCTIONS; Positioning the logs improperly will cause flame; Fine dust found in the bottom of the bag should not
14 W415-0153 / A / 10.29.01 DOOR CLOSING AND OPENING When installing the fire viewing door, a simple proceduremust be followed in order to not damage the door. Firstopen both side doors fully . Insert the pins on the door left side into the hinge bushings. Swing the door closed andengage the latches...
Page 15 - VENTING ACTION; OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; WHAT TO DO IF YOU SMELL GAS:
15 W415-0153 / A / 10.29.01 OPERATING INSTRUCTIONS The on-off switch is located on the back of the unit at the top left corner on models GDS28 and GS28. When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary conditioncaused by the curing of th...
Page 16 - LIGHTING INSTRUCTIONS; MAINTENANCE INSTRUCTIONS; Turn off the gas and unplug electrical; TO TURN OFF GAS
16 W415-0153 / A / 10.29.01 LIGHTING INSTRUCTIONS WARNING: WARNING: WARNING: WARNING: WARNING: The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermo- couple has cooled. Allow approximately 60 seconds for the thermocouple to cool. When lighting and rel...
Page 17 - REPLACEMENT BLOWER; INSTALLATION THROUGH THE REAR; FOR MODEL GDS28; INSTALLATION THROUGH THE FIRE-; FIGURE 35 - INSTALLATION FROM THE FRONT
17 W415-0153 / A / 10.29.01 REPLACEMENT BLOWER Blower replacement may be done through either thefirebox or from the rear of the unit. Using the rear panelis recommended. 1. Turn off the electrical power and the gas supply to the stove. INSTALLATION THROUGH THE REAR PANEL: FOR MODEL GDS28 2. Remove t...
Page 18 - PILOT BURNER ADJUSTMENT; FLAME MUST ENVELOP; A D J U S T M E N T S; VENTURI ADJUSTMENT
18 W415-0153 / A / 10.29.01 PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized flame. Turnin a clockwise direction to reduce the gas flow. FIGURE 36 FLAME MUST ENVELOP UPPER 3/8" TO 1/2" OF THERMOCOUPLE & THERMOPILE THERMOPILE THERMO-COUPLE FIGURE 37 P I INLET PRESS...
Page 19 - R E P L A C E M E N T S; ORDERING REPLACEMENT PARTS; DESCRIPTION
19 W415-0153 / A / 10.29.01 included with GD175 included with GD180 R E P L A C E M E N T S ORDERING REPLACEMENT PARTS Contact your dealer or the factory for questions concerning prices and policies on replacement parts. Normally all partscan be ordered through your Napoleon dealer or distributor. W...
Page 21 - PROBLEM; TROUBLE SHOOTING GUIDE
21 W415-0153 / A / 10.29.01 Pilot burning; no gasto main burner; gasknob is on 'HI'; wallswitch / thermostat ison. Main burner orifice is plugged. Faulty thermopile. Faulty themostat or switch. - remove stoppage in orifice. - replace. Faulty valve. - replace. PILOT THERMOPILE BURNER ELECTRODE THERMO...
Page 23 - Wolf Steel Fireplace Service History; This fireplace must be serviced annually depending on usage.
23 W415-0153 / A / 10.29.01 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Date Service Technician Name Service Performed Special Concerns Dealer Name