Page 2 - TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2 W415-0583 / B / 05.23.07 PG 2-5 INTRODUCTION Warranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING Vent lengths Venting Specifi cations Air Terminal Locations 10-15 INSTALLATION/FRAMING Wall & Ceiling Protection Using Flexible Vent Components ...
Page 3 - NAPOLEON® GAS FIREPLACE PRESIDENT’S LIFETIME LIMITED WARRANTY; the limited warranty. Light bulbs are not covered by this warranty.; CONDITIONS AND LIMITATIONS
3 W415-0583 / B / 05.23.07 ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD. NAPOLEON® products are manufactu...
Page 4 - Provide adequate ventilation and combustion air.; FIGURE 1; to conform with local; GENERAL INSTRUCTIONS; ” to top of fi replace opening.
4 W415-0583 / B / 05.23.07 Under extreme vent confi gurations, allow several minutes (5-15) for the fl ame to stabilize after ignition. Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operating the fi replace. Never obstruct the front opening ...
Page 5 - This fi replace may; be installed in an aftermarket permanently; Supplier 4; The; FIGURE 3; CARE OF GLASS; VENTING; VENTING LENGTHS & AIR TERMINAL
5 W415-0583 / B / 05.23.07 24" 16" 8" Do not use abrasive cleaners to clean glass. Buff lightly with a clean dry cloth. The glass is 3/16” ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer. DO NOT SUB-STITUTE MATERIALS. Clean the glass after the fi rst 10 hours of opera...
Page 6 - FIGURE 4; when; FIGURE 5; HORIZONTAL VENT RUN PLUS OFFSET IN FEET; DEFINITIONS; TOP EXIT / HORIZONTAL TERMINATION
6 W415-0583 / B / 05.23.07 VERTICAL RISE IN FEET V T FIGURE 4 when (H T ) < (V T ) Simple venting confi guration (only one 90° elbow) See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow, the following...
Page 7 - FIGURE 8; and V
7 W415-0583 / B / 05.23.07 H 2 H 1 V 1 90° See graph to determine the required verti-cal rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03 (two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 f...
Page 8 - FIGURE 9; TOP EXIT VERTICAL TERMINATION; unacceptable; TOP VERTICAL TERMINATION
8 W415-0583 / B / 05.23.07 REQUIRED VERTICAL RISE IN FEET V T HORIZONTAL VENT RUN PLUS OFFSET IN FEET H T when (H T ) < (V T ) FIGURE 9 For vent confi gurations requiring more than zero 90° elbow (top exit) or one 90° elbow (rear exit), the following formulas apply: For mula 1: H T < V T For mu...
Page 10 - VERTICAL INSTALLATION; IMPORTANT: For optimum performance, The stove pipe; HORIZONTAL INSTALLATION
10 W415-0583 / B / 05.23.07 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Napoleon® dealer. See Accessories to order the specifi c kit required. 1. Determine the air t e r m i n a l l o c a t i o n , c u t a n d f r a m e 11 ½ ...
Page 11 - If the attic space is; USING FLEXIBLE VENT COMPONENTS; HORIZONTAL AIR TERMINAL INSTALLATION
11 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the r o o f u s i n g t h e s c r e w s p r o v i d e d . The roof support is optional. In this case the venting is to be adequately supported using either an alternate m e t h o d s u i t a b l e t o t h ...
Page 12 - All inner exhaust and outer intake vent pipe joists; FIREPLACE VENT CONNECTION; USING RIGID VENT COMPONENTS; VERTICAL VENTING INSTALLATION
12 W415-0583 / B / 05.23.07 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws pro- vided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or ...
Page 13 - Proceed once the vent installation is complete.; GAS INSTALLATION
13 W415-0583 / B / 05.23.07 FLUE COLLAR RESTRICTOR PLATE TOP OF THE FIREBOX Proceed once the vent installation is complete. Note : All gas connections must be contained within the fi replace when complete. 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½...
Page 14 - WARNING; Facing and/or fi nishing; FRAMING; CLEARANCE TO COMBUSTIBLES; In order to avoid the possibility of exposed insulation
14 W415-0583 / B / 05.23.07 WARNING Facing and/or fi nishing material must never overhang into the fi replace opening. Do not distor t or force the frame kit components. When using a rough fi nish materi-al (i.e.; stone), maintain a ¼” - ½” border from the framing components. NON-COMBUSTIBLE FINISHING ...
Page 15 - MANTLE CLEARANCES; It is necessary to hard wire this fi replace.; ELECTRICAL CONNECTION; HARD WIRING CONNECTION; AUXILIARY; INSULATION
15 W415-0583 / B / 05.23.07 FIGURE 32 MANTLE CLEARANCES 0 3 4 7 8 9 11 13 1 2 5 6 7 10 12 H E I G H T M AN TL E MANTLE WIDTH Combustible mantle clearance c a n v a r y a c c o r d i n g t o t h e mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fi replace if any part ...
Page 16 - FINISHING / SERVICING; DOOR REMOVAL; Carefully slide the opening in the rear of the bowl over; . Rectangular Front Removal; OPTIONAL FRONT REMOVAL; Lift the burner out from the fi rebox.; CONTROL PANEL REMOVAL
16 W415-0583 / B / 05.23.07 Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed.The glass door is secured to the top front edge of the fi rebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door ...
Page 17 - CURVED DECORATIVE PANEL REMOVAL; Note: Be careful when; BURNER BASE REMOVAL
17 W415-0583 / B / 05.23.07 FIGURE 39 TOP EDGES BOTTOM EDGES Next, remove the 6 screws that secure the burner base. Once the gas has been disconnected, the burner train assembly will lift out. TOP SIDE OF ROCK CLUSTER 4. After rocks have been placed on the bowl, add the remaining rock by inserting t...
Page 18 - CONTROL; BATTERY REPLACEMENT; Tilt the control panel forward allowing access to the electode
18 W415-0583 / B / 05.23.07 BOWL BURNER CURVED DECORATIVE PANEL BURNERBOTTOM BURNERBASE SEE-TH RU W IN D O W ELECTRODEBOX(AA Battery Required) CONTROL PANEL CONTROL PANEL BATTERY REPLACEMENT 1. Remove the optional front. (Instructions on Pg. 17) 2. Tilt the control panel forward allowing access to t...
Page 19 - NIGHT LIGHT; REPLACEMENT; THE FIREBOX MUST BE SEALED.; Over tightening the screws could break the lens.; OPERATION / MAINTENANCE; FIREPLACE OPERATION
19 W415-0583 / B / 05.23.07 Y o u r comes equipped with our Night Light TM . The light has been pre-wired and is controlled from the remote control. If in the event the lamp or lens needs to be replaced, follow the instructions below. Unplug the wire harness / transformer from the junction box insid...
Page 20 - HAND HELD REMOTE OPERATIONS
20 W415-0583 / B / 05.23.07 5. FAN SPEED SETTING This function controls the speed of the hot air circulating fan. To change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6....
Page 21 - On subsequent restoration of the main power and with
21 W415-0583 / B / 05.23.07 CHILD SAFETY LOCK-OUTThis function is to deactivate con-trol button. The function is active when the lock icon is lit. To activate this function press the ON / OFF button and within one second the UP keyTo reactivate the remote control buttons follow the same sequence, pr...
Page 22 - DIP SWIT
22 W415-0583 / B / 05.23.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) FIGURE 57
Page 23 - OPERATING INSTRUCTIONS; LIGHTING INSTRUCTIONS; Purge all gas lines with the glass door of the fi replace
23 W415-0583 / B / 05.23.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly. B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor. C. Use...
Page 24 - ADJUSTMENTS; PILOT BURNER ADJUSTMENT; Air Shutter Openings; TURN OFF THE GAS AND ELECTRICAL POWER; at least; MAINTENANCE
24 W415-0583 / B / 05.23.07 AIRSHUTTER OPENING Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting from the burner ports. The fl ame may not appear yellow immediately; allow 15 to 30 minut...
Page 25 - CONVERSION KIT; “CAUTION”; SIT; Do not use open fl ame.
25 W415-0583 / B / 05.23.07 CONVERSION KIT This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instruction is not followed e...
Page 26 - PART NO. DESCRIPTION; REPLACEMENTS; REPLACEMENT PARTS; mocouple supplied by Wolf Steel Ltd.
26 W415-0583 / B / 05.23.07 # PART NO. DESCRIPTION 1 W135-0275 OUTER ROCKS 2 W135-0304 SINGLE ROCK 3 W135-0277 BOWL 4 GL-655 ROCK SET ASSEMBLY 5 W565-0090 WIRE MESH 6* W390-0002 DOOR LATCH ( EA ) 7 W725-0047 NATURAL GAS VALVE - MODULATING 7 W725-0048 PROPANE GAS VALVE - MODULATING 8* W455-0019 NATUR...
Page 28 - TROUBLE SHOOTING GUIDE; SYMPTOM
28 W415-0583 / B / 05.23.07 W h i t e / g r e y f i l m forms. Sulphur from fuel is being deposited on glass, logs or c o m b u s t i o n c h a m b e r s u r -faces. - clean the glass with a gas fi replace glass cleaner. DO NOT CLEAN GLASS WHEN HOT. If deposits are not cleaned off regularly, the glas...
Page 29 - Gas piping is undersized.
29 W415-0583 / B / 05.23.07 Remote wall switch is in “OFF” position; main burner comes on when gas knob is turned to “ON” position. Wall switch is mounted upside down - reverse. Faulty valve. - replace. - replace. Remote wall switch is ground-ing. - check for ground (short); repair ground or replace...
Page 30 - Fireplace Service History; This fireplace must be serviced annually depending on usage
30 W415-0583 / B / 05.23.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SER VICE TECHNICIAN NAME SER V ICE PERFORMANCE SPECIAL CONCERNS
Page 31 - NOTES