Page 2 - TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2 W415-0434 / C / 03.24.05 PG2-5 INTRODUCTION WarrantyD i m e n s i o n sGeneral InstructionsGeneral InformationCare of Glass & Plated Parts 5-10 VENTING Vent lengthsVenting SpecificationsAir Terminal Locations 11-15 INSTALLATION/FRAMING Wall & Ceiling ProtectionUsing Flexible Vent Component...
Page 3 - NAPOLEON GAS FIREPLACE PRESIDENT'S LIFETIME LIMITED WARRANTY; CONDITIONS AND LIMITATIONS
3 W415-0434 / C / 03.24.05 ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTEREDTRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD. NAPOLEON gas fireplaces are manuf...
Page 4 - WARNING: The door for this fireplace is sold; FIGURE 1; GENERAL INSTRUCTIONS
4 W415-0434 / C / 03.24.05 Purge all gas lines with the glass door of the fireplace open.Assure that a continuous gas flow is at the burner beforeclosing the door. Under extreme vent configurations, allow several minutes(5-15) for the flame to stabilize after ignition. Eight (8") inches is the m...
Page 5 - FIGURE 3; CARE OF GLASS, AND PLATED PARTS; VENTING
5 W415-0434 / C / 03.24.05 Do not use abrasive cleaners to clean plated parts. Bufflightly with a clean dry cloth. The glass is 3/16" ceramicglass available from your Napoleon / Wolf Steel Ltd. dealer.DO NOT SUBSTITUTE MATERIALS. Clean the glass afterthe first 10 hours of operation with a recomm...
Page 6 - DEFINITIONS; TOP EXIT / HORIZONTAL TERMINATION
6 W415-0434 / C / 03.24.05 when (H T ) < (V T ) Simple venting configuration (only one 90° elbow) V E R T I C A L R I S E I N FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent configurations requiring more than one 90° el-bow, t...
Page 7 - FIGURE 6; FIGURE 8
7 W415-0434 / C / 03.24.05 H 2 H 1 V 1 90° See graph to determine the required ver-tical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft...
Page 8 - FIGURE 9; VERTICAL TERMINATION
8 W415-0434 / C / 03.24.05 REQUIRED VERTICAL RISE IN FEET V T HORIZONTAL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptablevalues for H T and V T . when (H T ) < (V T ) Simple venting configurations FIGURE 9 For vent configurations requiring more than zero 90°...
Page 10 - AIR TERMINAL INSTALLATIONS; non; CANADIAN; INSTALLATIONS
10 W415-0434 / C / 03.24.05 AIR TERMINAL INSTALLATIONS *** R e c o m m e n d e d t o p r e v e n t c o n d e n s a t i o n o n w i n d o w s a n d t h e r m a l b r e a k a g e * * * * * * * * * * It is recommended to use a heat shield and to maximize the distance to vinyl clad sof f its. * * * * * ...
Page 11 - OR; INSTALLATION; HORIZONTAL INSTALLATION; HORIZONTAL INSTALLATION:
11 W415-0434 / C / 03.24.05 FIGURE 14 OR This application occurswhen venting through aroof. Installation kits forvarious roof pitches areavailable from your Na-poleon dealer. See Ac-cessories to order thespecific kit required. 1. Determine the air ter- minal location, cut andframe 9½ inch open- ings...
Page 12 - USING FLEXIBLE VENT COMPONENTS
12 W415-0434 / C / 03.24.05 FIGURE 20 Use only approved aluminum flexible liner kits marked" Wolf Steel Approved Venting" as identified by thestamp only on the 7" outer liner.For optimum performance it is recommended that allhorizontal runs have a minimum ¼ inch rise per footusing flexib...
Page 13 - The air terminal may be recessed into the; FIREPLACE VENT CONNECTION; USING RIGID VENT COMPONENTS; VERTICAL VENTING INSTALLATION
13 W415-0434 / C / 03.24.05 FIGURE 23 1. Move the fireplace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 16. The roof support is optional. In this case the ventingis to be adequately supportedusing either an alternate methodsuitable to the authority having ...
Page 14 - TILES; In order to avoid the possibility of exposed; GAS INSTALLATION; Proceed once the vent installation is complete.; WIRE SIZE
14 W415-0434 / C / 03.24.05 * * * * * When using the optional ornamental facia and panels, the minimum height from the top of the unit to the mantleis 7". ** A steel stud header is recommended, however tradi-tional combustible header material may be used. TILES GD425 BLACK PAINTED FIREPLACESURFA...
Page 15 - MANTLE CLEARANCES
15 W415-0434 / C / 03.24.05 Combustible mantle clearance can vary according to themantle depth. Use the graph to help evaluate the clear-ance needed. FIGURE 37 MANTLE CLEARANCES ** EXAMPLE A - NON-COMBUSTIBLE MATERIAL It is best to frame your fireplace after it is positioned andthe vent system is in...
Page 16 - FIGURE 42: LOWER LOUVRE ASSEMBLY; DOOR CLOSING AND OPENING; FINISHING; DOOR INSTALLATION; HINGE
16 W415-0434 / C / 03.24.05 Open the valve control door.Hook the top and bottom doorl a t c h e s , l o c a t e d a t t h e r i g h tside of the door into the corre-sponding slots in the door. The door latch holes are elongated for door levelling. Tolevel the door, it may need to be lifted up at the...
Page 17 - L38 LOUVRE INSTALLATION; HOOD; LOG SHIPPING BRACKET; DECORATIVE PANELS; SOLD; CHARCOAL STRIPS
17 W415-0434 / C / 03.24.05 A C B L38 LOUVRE INSTALLATION FIGURE 43 a-c HOOD Attach the hood by pressing thetop flange into the clips alongthe top of the louvre opening.Secure using a screw throughthe centre slot. LOWER LOUVRES Insert the hinge clips into theslots located at the bottom leftand right...
Page 18 - LOG PLACEMENT
18 W415-0434 / C / 03.24.05 Glowing embers (not supplied) maybe used to enhancethe flame's appearance. 4. Place log #4, with the charred branch pointed inward. Locate the pins into the holes in log#1 and log#2, this willhold the rear log in position. 5. Place the end of log #5 on the right end of lo...
Page 19 - THE FIREBOX MUST BE SEALED.; ACCENT LITE REPLACEMENT
19 W415-0434 / C / 03.24.05 The FIRE LOG ACCENT LIGHT is provided with a manual "in-line" switch to turn the light on and off. There are alternate meth-ods of operating the light.An example of one method would be to "hard-wire" a wall switch.The switch could be installed in desired l...
Page 20 - BLOWER INSTALLATION; BLOWER SYSTEM; THERMODISC REPLACEMENT; BLOWER REPLACEMENT
20 W415-0434 / C / 03.24.05 BLOWER INSTALLATION FIGURE 51 The Napoleon STARfire comes equipped with a blower, aheat sensor, variable on/off speed control and a power cord.The blower is thermally activated, so when it is turned on, itwill automatically start approximately 15 minutes after light-ing t...
Page 21 - depressed; OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS
21 W415-0434 / C / 03.24.05 A. This fireplace is equipped with a pilot which must belit by hand while following these instructions exactly. B. Before operating smell all around the fireplace area forgas and next to the floor because some gas is heavierthan air and will settle on the floor. C. Use on...
Page 22 - at least once a year; MAINTENANCE; ADJUSTMENTS; PILOT BURNER ADJUSTMENT; Air Shutter Openings
22 W415-0434 / C / 03.24.05 Closing the air shutter will cause a more yellow flame, butcan lead to carboning. Opening the air shutter will cause amore blue flame, but can cause flame lifting from the burnerports. The flame may not appear yellow immediately; allow15 to 30 minutes for the final flame ...
Page 23 - REPLACEMENTS; REPLACEMENT PARTS
23 W415-0434 / C / 03.24.05 # PART NO. DESCRIPTION 1 W135-0205 #1 - REAR LOG 2 W135-0206 #2 - MIDDLE LOG 3 W135-0207 #3 - RIGHT LOG 4 W135-0208 #4 - LEFT LOG 5 W135-0218 #5 - CROSSOVER LOG 6 GL-644 LOG SET ASSEMBLY 7* W090-0095 L CHARCOAL STRIP 8* W090-0096 R CHARCOAL STRIP 9* W390-0002 DOOR LATCH (...
Page 25 - TROUBLE SHOOTING GUIDE; SYMPTOM
25 W415-0434 / C / 03.24.05 W h i t e / g r e y f i l mforms. Sulphur from fuel is beingdeposited on glass, logs orcombustion chamber sur-faces. - clean the glass with a gas fireplace glass cleaner. DO NOT CLEANGLASS WHEN HOT.If deposits are not cleaned off regularly, the glass may becomepermanently...
Page 27 - This fireplace must be serviced annually depending on usage.
27 W415-0434 / C / 03.24.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Dealer Name
Page 28 - NOTES