Page 2 - TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2 W415-0381 / C / 05.13.04 WARNING ••••• Do not burn wood or other materials in this fireplace.• Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are inthe same ro...
Page 4 - GENERAL INSTRUCTIONS
4 W415-0381 / C / 05.13.04 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV-ICED BY A QUALIFIED INSTALLER to conform with local codes.In absence of local codes, install the BGD42 to the current Na-tional Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149,Installation Codes. Installation practice...
Page 5 - FIGURE 1; VENTING; VENTING LENGTHS
5 W415-0381 / C / 05.13.04 Use only Wolf Steel or Simpson Dura-Vent Model DV-GSventing components. Minimum and maximum vent lengths,for both horizontal and vertical installations, and air termi-nal locations for either system are set out in this manualand must be adhered to. For Simpson Dura-Vent, f...
Page 6 - non; CANADIAN; INSTALLATIONS; AIR TERMINAL INSTALLATIONS; FIGURE 2
6 W415-0381 / C / 05.13.04 * Recommended to prevent condensation on windows and thermal breakage ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of18". It is recommended to maximize the distance to vinyl clad soffits. *** The periscope G...
Page 7 - FIGURE 4; TYPICAL VENT INSTALLATIONS; PERISCOPE TERMINATION
7 W415-0381 / C / 05.13.04 Use the GD401 periscope kit to locate the air terminationabove grade. The periscope must be installed so that whenfinal grading is completed, the bottom air slot is located aminimum of 12 inches above grade. The maximum allow-able vent length depends on the fireplace, as i...
Page 8 - VENTING APPLICATION FLOW CHART
8 W415-0381 / C / 05.13.04 VER VER VER VER VERTICAL TICAL TICAL TICAL TICAL TERMIN TERMIN TERMIN TERMIN TERMINA A A A ATION TION TION TION TION HORIZONT HORIZONT HORIZONT HORIZONT HORIZONTAL AL AL AL AL TERMIN TERMIN TERMIN TERMIN TERMINA A A A ATION TION TION TION TION vertical rise vertical rise v...
Page 9 - HORIZONTAL TERMINATION; REQUIRED
9 W415-0381 / C / 05.13.04 ELBOW VENT LENGTH VALUES DEFINITIONS HORIZONTAL TERMINATION REQUIRED V E R T I C A LRISE IN FEET(V T ) CALCULATED HORIZONTAL VENT RUNPLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) Simple venting configuration (only one 45º and 90° elb...
Page 10 - FIGURE 7; FIGURE 8
10 W415-0381 / C / 05.13.04 V 1 HORIZONTAL TERMINATION See graph to determine the re-quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 2...
Page 11 - VERTICAL TERMINATION; FIGURE 9
11 W415-0381 / C / 05.13.04 VERTICAL TERMINATION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T...
Page 13 - OR; INSTALLATION
13 W415-0381 / C / 05.13.04 This application occurswhen venting through aroof. Installation kits forvarious roof pitches areavailable from your Napo-leon dealer. See Accesso-ries to order the specifickit required. 1. Determine the air terminal location, cut and frame 10 inch openings in the ceiling ...
Page 14 - DO NOT CLAMP THE FLEXIBLE; USING FLEXIBLE VENT COMPONENTS
14 W415-0381 / C / 05.13.04 Use only approved aluminum flexible liner kits marked: "Wolf Steel Approved Venting" as identified by the stamp only on the 8” outer liner. FIGURE 18 For safe and proper operation of the fireplace, followthe venting instructions exactly. A VENT SHIELD MUST BE USED...
Page 15 - FIREPLACE VENT CONNECTION; USING RIGID VENT COMPONENTS
15 W415-0381 / C / 05.13.04 FIGURE 25 The vent system must be supported approximately every 3feet for both vertical and horizontal runs. Use Wolf Steelvent spacers every 3 feet and either side of each elbow tomaintain the minimum 1¼" clearance between the outerand inner vent pipes. Use Wolf Stee...
Page 16 - Continue adding rigid venting sections, sealing and; WIRE SIZE; VENT; VERTICAL VENTING INSTALLATION
16 W415-0381 / C / 05.13.04 1. Move the fireplace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 21. The roof support is optional. In this case the venting is to be adequately supported using ei-ther an alternate method suitable to the authority havingjurisdi...
Page 17 - MOBILE HOME INSTALLATION
17 W415-0381 / C / 05.13.04 It is best to frame your fireplace after it is positioned andthe vent system is installed. Use 2x4's and frame to localbuilding codes. FIGURES 31-33. It is not necessary to install a hearth extension with thisfireplace system. When roughing in the fireplace, raise the fir...
Page 18 - NAILING TAB INSTALLATION
18 W415-0381 / C / 05.13.04 NAILING TAB 1) Attach the nailing tabs to the cornerposts using the 2 sheet metal screwssupplied. Secure through the centre ofthe top and bottom slots in the nailingtab and then through the existing holesin the corner posts. If there are no existing holes, followthese ins...
Page 19 - UPPER LOUVRES; LOWER LOUVRES; L42 LOUVRE INSTALLATION; LOGO; FINISHING; GDL42 LOUVRE INSTALLATION
19 W415-0381 / C / 05.13.04 1. Remove the upper louvres, and open the glass door.Remove the logs. 2. Remove the securing screw al-ready in place at the back of the fire-box. If the unit is supplied with a rearlog support, remove before install-ing the rear panel. Place the rearpanel against the back...
Page 20 - GLOWING EMBERS; LOG PLACEMENT; CHARCOAL EMBERS
20 W415-0381 / C / 05.13.04 4. Cradle the notch on the bottom of the left crossover log (#4) around the left outermost grate post and the top intothe pocket provided on the back log. Position the notchlocated on the end of the center log (#5) against the middlegrate post with the other end of the lo...
Page 21 - The wire harness provided in this kit is a universal; OPTIONAL BLOWER INSTALLATION
21 W415-0381 / C / 05.13.04 INSTALLATION TO BE DONE BY A QUALIFIED INSTALLERand must be electrically connected and grounded in ac-cordance with local codes. In the absense of local codes,use the current C S A C 2 2 . 1 C A N A D I A N ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL...
Page 22 - OPTIONAL FAN INSTALLATION
22 W415-0381 / C / 05.13.04 ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-FIED INSTALLER and must be connected and groundedin accordance with local codes. In the absence of localcodes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the U...
Page 23 - OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; MAINTENANCE
23 W415-0381 / C / 05.13.04 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If...
Page 24 - ADJUSTMENTS; PILOT BURNER ADJUSTMENT
24 W415-0381 / C / 05.13.04 Adjust the pilot screw to provide properly sized flame. Turnin a clockwise direction to reduce the gas flow. Air shutters have been factory set open according to thechart below: These settings are for the maximum horizontal vent run.-Adjustment may be required depending o...
Page 25 - REPLACEMENT PARTS; REPLACEMENTS; FLEXIBLE VENT KITS; ACCESSORIES; ROOF TERMINAL KITS
25 W415-0381 / C / 05.13.04 # PART NO. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 *W680-0005 THERMOCOUPLE 4 W010-0800 NATURAL GAS PILOT ASSEMBLY 4 W010-0801 PROPANE GAS PILOT ASSEMBLY 5* W573-0008 HIGH TEMPERATURE SEALANT 6 W455-0069 NATURAL GAS PILOT INJECTOR 6 W455-0067 PROPANE...
Page 27 - TROUBLE SHOOTING GUIDE; SYMPTOM
27 W415-0381 / C / 05.13.04 Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button ignitor.- check if the push button ignitor needs tightening.- replace the wire if the wire insulation is broken or frayed.- replace the electrode if the ceram...