Page 2 - TABLE of CONTENTS
2 W415-0614 / A / 07.24.07 PG2-5 INTRODUCTION Warnings and Safety Precautions Warranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-9 VENTING Vent lengths Venting Specifi cations Air Terminal Locations 10-14 INSTALLATION/FRAMING Wall & Ceiling Protection ...
Page 3 - CONDITIONS AND LIMITATIONS
3 W415-0614 / A / 07.24.07 ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON®® IS A REGISTERED TRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD. NAPOLEON® products are manufact...
Page 4 - FIGURE 1; GENERAL INSTRUCTIONS
4 W415-0614 / A / 07.24.07 6" Provide adequate ventilation and combustion air. Provide adequate accessibility clearance for servicing and operat-ing the fireplace. Never obstruct the front opening of the fireplace. Objects placed in front of the fireplace must be kept a minimum of 48” from the f...
Page 5 - FIGURE 3; CARE OF GLASS, AND PLATED PARTS; VENTING
5 W415-0614 / A / 07.24.07 We Suggest that our gas hearth products be installed and serviced by profession- als who are certified in the U.S. by the National Fire- place Institute (NFI) as NFI Gas Specialists. 24" 16" 12" Do not use abrasive cleaners to clean glass. Buff lightly with a c...
Page 6 - FIGURE 4; DEFINITIONS; TOP EXIT / HORIZONTAL TERMINATION
6 W415-0614 / A / 07.24.07 Simple venting confi guration (only one 90° elbow) V E R T I C A L R I S E I N FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi gurations requiring more than one 90° elbow, the following formulas app...
Page 7 - FIGURE 8
7 W415-0614 / A / 07.24.07 H 2 H 1 V 1 90° See graph to determine the required vertical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03 (two 90° elbows - 90°) = .03(180° - 90°) = 2.7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft...
Page 8 - unacceptable; TOP VERTICAL TERMINATION; FIGURE 9; TOP EXIT VERTICAL TERMINATION
8 W415-0614 / A / 07.24.07 MAXIMUM V E RT I C A L R I S E I N FEET V T HORIZONTAL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T . For vent confi...
Page 9 - AIR TERMINAL INSTALLATIONS; non; CANADIAN; INSTALLATIONS
9 W415-0614 / A / 07.24.07 AIR TERMINAL INSTALLATIONS ***** Recommended to prevent condensation on windows and thermal breakage ** ** ** ** ** It is recommended to use a heat shield and to maximize the distance to vinyl clad soffi ts. *** *** *** *** *** The periscope GD-401 requires a minimum 18 in...
Page 10 - OR; INSTALLATION
10 W415-0614 / A / 07.24.07 This application occurs when venting through an exterior wall. Having determined the air terminal loca-tion, cut and frame a hole in an exterior wall. The recommended framed opening is 14 1 / 2 ” W x 14 1 / 2 ” H with a minimum 14 1 / 2 ” round or square opening inside a ...
Page 11 - If the attic space; USING FLEXIBLE VENT COMPONENTS
11 W415-0614 / A / 07.24.07 7. Using the 10” diameter fl exible aluminium liner, apply sealant, slide a minimum of 2” over the fi replace combustion air collar and secure with 6 #8 screws. 1. Move the fi replace into position. 2. Fasten the roof support to the roof using the screws provided. The roof s...
Page 12 - FIREPLACE VENT CONNECTION; MOBILE HOME INSTALLATION
12 W415-0614 / A / 07.24.07 Proceed once the vent installation is complete. Note : All gas connections must be contained within the fireplace when complete. 1. The fi replace is designed to accept a ½” gas supply line. The fi replace is equipped with a ½” manual shut-off valve, and an 18” listed fl exi...
Page 13 - WARNING; Facing and/or fi nishing; FRAMING; ” to sides of fireplace opening.
13 W415-0614 / A / 07.24.07 WARNING Facing and/or fi nishing material must never overhang into the fi replace opening. 59 1/4 " 1" MIN 1" MIN 29" 10" MIN 72" 29" 59 1/4 " 59 1/4 " 29" 59 1/4 " 116" 82" FRAMING CLEARANCE TO COMBUSTIBLES MAINTAIN THESE...
Page 14 - It is necessary to hard wire this fireplace.; ELECTRICAL CONNECTION; HARD WIRING CONNECTION; LIGHT; VALVE
14 W415-0614 / A / 07.24.07 FIGURE 30 MANTLE CLEARANCES 0 3 4 7 8 9 1 2 5 6 7 H E I G H T M AN TL E MANTLE WIDTH 5 6 4 3 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fireplace if any part has been under water...
Page 15 - LOG SHIPPING BRACKET; ROD; FINISHING; Careful door is; GLASS/DOOR REPLACEMENT
15 W415-0614 / A / 07.24.07 1 . Place the door frame face d o w n c a r e f u l not to scratch the paint. 2 . Center the gasketed glass inside the door frame with the thick side of the g a s k e t f a c i n g up. 3 . Bend the glass retainers l o c a t e d a l o n g the edge of the door frame over th...
Page 16 - INSTALL PANELS IN THE FOLLOWING ORDER:; RETAINER; BRICK PANEL INSTALLATION
16 W415-0614 / A / 07.24.07 NOTE: Refer to the FINISHING section of the BGD90NT/ PT Installation Manual for instructions on removing the door and log shipping bracket before proceeding. Brick panels are shipped separate from unit due to the brittle material of the bricks, care must be taken not to b...
Page 18 - NIGHT LIGHT REPLACEMENT; THE FIREBOX MUST BE SEALED.
18 W415-0614 / A / 07.24.07 GLOWING EMBERS CHARCOAL EMBERS Randomly place the charcoal embers along the front and sides of the Hearth Panels in a realistic manner. Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers.Note: Both charcoal embers ...
Page 19 - CONTROL MODULE REMOVAL; REMOTE AND VALVE ACCESS; VALVE REMOVAL
19 W415-0614 / A / 07.24.07 RECEIVER SLOT SPARK MODULE VALVE WING NUT 1. Remove access panel from inside the fi rebox. 2. Unplug the control module from the junction box 3. Pull up on the control module being held down with velcro and disconnect the plugs (fan, aux). Remove wiring harness from the fr...
Page 20 - OPERATION / MAINTENANCE; FIREPLACE OPERATION
20 W415-0614 / A / 07.24.07 To operate this fi replace using the remote, the pilot must be running and the gas valve turned to the “ON” position. Ensure that the receiver has power and the backup switch is in the auto position. 1. Install the batteries (AAA) into the remote control transmitter. The “...
Page 23 - DIP SWIT
23 W415-0614 / A / 07.24.07 DIP SWIT CH NUMBER (0 = ON / 1 = OFF)
Page 24 - OPERATING INSTRUCTIONS; PI LOT
24 W415-0614 / A / 07.24.07 A. This fi replace is equipped with a pilot which must be lit by hand while following these instructions exactly. B. Before operating smell all around the fi replace area for gas and next to the fl oor because some gas is heavier than air and will settle on the fl oor. C. Use...
Page 25 - ADJUSTMENTS; TURN OFF THE GAS AND ELECTRICAL POWER; MAINTENANCE; Failure to position the parts in accordance; SIT; BURNER
25 W415-0614 / A / 07.24.07 ADJUSTMENTS TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE FIREPLACE. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after ser-vicing. This fi replace an...
Page 26 - PILOT BURNER ADJUSTMENT; Air Shutter Openings; FLAME CHARACTERISTICS; Check Pressure Readings:
26 W415-0614 / A / 07.24.07 PILOT BURNER THERMOCOUPLE THERMOPILE FLAME MUST ENVELOP UPPER 3/8” TO 1/2” OF THERMOCOUPLE & THERMOPILE Closing the air shutter will cause a more yellow fl ame, but can lead to carboning. Opening the air shutter will cause a more blue fl ame, but can cause fl ame lifting...
Page 27 - REPLACEMENTS; NAPOLEON®; REPLACEMENT PARTS
27 W415-0614 / A / 07.24.07 # PART NO. DESCRIPTION 1* W390-0002 DOOR LATCH ( EA ) 2 W725-0047 NATURAL GAS VALVE - MODULATING 2 W725-0048 PROPANE GAS VALVE - MODULATING 3 W455-0040 #41 NATURAL GAS ORIFICE 3 W455-0058 #35 NATURAL GAS ORFICE 3 W455-0059 #53 PROPANE GAS ORIFICE 4 W680-0014 THERMOCOUPLE ...
Page 29 - TROUBLE SHOOTING GUIDE; SYMPTOM
29 W415-0614 / A / 07.24.07 W h i t e / g r e y f i l m forms. Sulphur from fuel is being deposited on glass, logs or c o m b u s t i o n c h a m b e r s u r -faces. - clean the glass with a gas fi replace glass cleaner. DO NOT CLEAN GLASS WHEN HOT. If deposits are not cleaned off regularly, the glas...
Page 31 - Fireplace Service History; This fireplace must be serviced annually depending on usage
31 W415-0614 / A / 07.24.07 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SER VICE TECHNICIAN NAME SER V ICE PERFORMANCE SPECIAL CONCERNS
Page 32 - NOTES