Page 2 - PLEASE RETAIN THIS MANUAL; TABLE of CONTENTS; RETAIN THIS MANUAL FOR FUTURE REFERENCE; WARNING
W415-0326 / C / 11.23.07 2 Framing Minimum Mantel and Enclosure Clearances Nailing Tab Installation 19-20 FINISHING Log Placement Charcoal Embers Vermiculite Glowing Embers Logo Placement Louvre Installation 21 OPTIONAL BLOWER INSTALLATION 21 OPTIONAL FAN INSTALLATION / GD36 THERMOSTATIC SENSOR CONT...
Page 4 - GENERAL INSTRUCTIONS
W415-0326 / C / 11.23.07 4 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the BGD48 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practice...
Page 5 - INSTALLATION OVERVIEW
W415-0326 / C / 11.23.07 5 FIGURE 1 INSTALLATION OVERVIEW FIGURE 2
Page 6 - VENTING; VENTING LENGTHS
W415-0326 / C / 11.23.07 6 Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components.Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be ...
Page 7 - MINIMUM AIR TERMINAL LOCATION CLEARANCES
W415-0326 / C / 11.23.07 7 MINIMUM AIR TERMINAL LOCATION CLEARANCES FIGURE 3
Page 8 - SPECIAL VENT INSTALLATIONS; PERISCOPE TERMINATION; TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS
W415-0326 / C / 11.23.07 8 FIGURE 5 SPECIAL VENT INSTALLATIONS NOTE: When terminating vertically, the restrictor plate W500-0205 must be installed. Refer to Restricting Vertical Vents. PERISCOPE TERMINATION TYPICAL MINIMUM AND MAXIMUM VENT LENGTHS FIGURES 4 a-b Use only GD401 periscope kit to locate...
Page 9 - VENTING APPLICATION FLOW CHART
W415-0326 / C / 11.23.07 9 VERTICAL TERMINATION HORIZONTAL TERMINATION vertical rise is equal to or greater t h a n t h e horizontal runhorizontal run + verti-c a l r i s e t o m a x i m u m of 40 feet vertical rise is equal to or greater t h a n t h e horizontal run h o r i z o n t a l run + verti-...
Page 10 - HORIZONTAL TERMINATION
W415-0326 / C / 11.23.07 10 ELBOW VENT LENGTH VALUES DEFINITIONS HORIZONTAL TERMINATION REQUIRED V E R T I C A L RISE IN FEET (V T ) CALCULATED HORIZONTAL VENT RUN PLUS OFF-SETS IN FEET (H T ) FIGURE 6 45º FIGURE 7 90° H 1 H 2 when (H T ) < (V T ) Simple venting confi guration (only one 45º and 90...
Page 12 - VERTICAL TERMINATION
W415-0326 / C / 11.23.07 12 VERTICAL TERMINATION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03 (one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V ...
Page 14 - INSTALLATION; VENT HEAT SHIELD INSTALLATION; ADJUSTABLE FIRESTOP INSTALLATION
W415-0326 / C / 11.23.07 14 FIGURE 16 147/16" W x 161/4" H. See fi gure16. This application occurs w h e n v e n t i n g t h r o u g h a roof. Installation kits for various roof pitches are available from your Napoleon® dealer. See Accessories to order the specifi c kit required. 1. Determine ...
Page 15 - USING FLEXIBLE VENT COMPONENTS; FIREPLACE VENT CONNECTION
W415-0326 / C / 11.23.07 15 FIGURE 25 4. Insert the liners through the fi restop maintaining the required clearance to combustibles. Holding the air terminal (lettering in an upright, readable position), secure to the exterior wall and make weather tight by sealing with caulking (not supplied). 5. Ap...
Page 16 - USING RIGID VENT COMPONENTS; VERTICAL VENTING INSTALLATION; RESTRICTING VERTICAL VENTS
W415-0326 / C / 11.23.07 16 FIGURE 31 RESTRICTOR PLATE TOP OF THE FIREBOX FLUE COLLAR The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼...
Page 17 - GAS INSTALLATION; MOBILE HOME INSTALLATION; OPTIONAL WALL SWITCH
W415-0326 / C / 11.23.07 17 Proceed once the vent installation is complete. NOTE: All gas connections must be contained within the fi re-place when complete. 1. Move the fi replace into position and secure to the fl oor through the 1/4" holes located at either side of the base. 2. The fi replace is ...
Page 19 - NAILING TAB INSTALLATION; FINISHING; LOG PLACEMENT / GLOWING EMBERS
W415-0326 / C / 11.23.07 19 NAILING TAB FIGURE 39 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, ...
Page 20 - CHARCOAL EMBERS; GLOWING EMBERS; LOGO
W415-0326 / C / 11.23.07 20 B A Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner. Fine dust found in the bottom of the bag should not be used. Sprinkle vermiculite around the charcoal embers. Note: Both charcoal embers and vermiculite are not...
Page 21 - OPTIONAL BLOWER INSTALLATION; OPTIONAL FAN INSTALLATION
W415-0326 / C / 11.23.07 21 FIGURE 50 FIGURE 45 INSTALLATION TO BE DONE BY A QUALIFIED I N S TA L L E R a n d m u s t be electrically connected and grounded in accord-ance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELEC - T R I C A L C O D E i n C a n a d a ...
Page 22 - OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; MAINTENANCE
W415-0326 / C / 11.23.07 22 When lit for the fi rst time, the fi replace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur agai...
Page 23 - ADJUSTMENTS; PILOT BURNER ADJUSTMENT; FRONT REAR
W415-0326 / C / 11.23.07 23 Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise direction to reduce the gas fl ow. Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.- Adjust-ment may be required dependi...
Page 24 - REPLACEMENT PARTS; REPLACEMENTS; ACCESSORIES; FLEXIBLE VENT KITS
W415-0326 / C / 11.23.07 24 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE ** 4 W010-0796 NATURAL GAS PILOT ASSEMBLY 4 W010-0797 PROPANE GAS PILOT ASSEMBLY 5* W573-0008 HIGH TEMPERATURE SEALANT 6* W660-0005 ON/OFF TOGGLE SWITCH 7 W455-0070 NATURAL GAS PILOT INJECTOR - #62 ...
Page 26 - TROUBLE SHOOTING GUIDE; SYMPTOM
W415-0326 / C / 11.23.07 26 TROUBLE SHOOTING GUIDE Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button igniter.- check if the push button igniter needs tightening.- replace the wire if the wire insulation is broken or frayed.- replace the...
Page 28 - NOTES