Page 2 - TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
2 W415-0533 / E / 02.09.06 WARNING • Do not burn wood or other materials in this fireplace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room...
Page 4 - GENERAL INSTRUCTIONS
4 W415-0533 / E / 02.09.06 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV-ICED BY A QUALIFIED INSTALLER to conform with local codes.In absence of local codes, install the BGD42 to the current Na-tional Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149,Installation Codes. Installation practice...
Page 5 - GAS STOVE; FIGURE 1; VENTING; VENTING LENGTHS
5 W415-0533 / E / 02.09.06 Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontaland vertical installations, and air terminal locations for ei-ther system are set out in this manual and must be...
Page 6 - non; CANADIAN; INSTALLATIONS; AIR TERMINAL INSTALLATIONS; FIGURE 2
6 W415-0533 / E / 02.09.06 * Recommended to prevent condensation on windows and thermal breakage ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of18". It is recommended to maximize the distance to vinyl clad soffits. *** The periscope G...
Page 7 - FIGURE 4; TYPICAL VENT INSTALLATIONS; PERISCOPE TERMINATION
7 W415-0533 / E / 02.09.06 Use the GD401 periscope kit to locate the air terminationabove grade. The periscope must be installed so that whenfinal grading is completed, the bottom air slot is located aminimum of 12 inches above grade. The maximum allow-able vent length depends on the fireplace, as i...
Page 8 - VENTING APPLICATION FLOW CHART
8 W415-0533 / E / 02.09.06 VERTICAL TERMINATION HORIZONTAL TERMINATION vertical riseis equal toor greaterthan thehorizontalrun h o r i z o n t a lrun + verti-cal rise tom a x i m u mof 40 feet vertical riseis equal toor greaterthan thehorizontalrun h o r i z o n t a lrun + verti-cal rise tom a x i m...
Page 9 - HORIZONTAL TERMINATION; REQUIRED
9 W415-0533 / E / 02.09.06 ELBOW VENT LENGTH VALUES DEFINITIONS HORIZONTAL TERMINATION REQUIRED V E R T I C A LRISE IN FEET(V T ) CALCULATED HORIZONTAL VENT RUNPLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) Simple venting configuration (only one 45º and 90° elb...
Page 10 - FIGURE 7; FIGURE 8
10 W415-0533 / E / 02.09.06 V 1 HORIZONTAL TERMINATION See graph to determine the re-quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 2...
Page 11 - VERTICAL TERMINATION; FIGURE 9
11 W415-0533 / E / 02.09.06 90° 90° V 1 H 1 H 2 V 2 45° 90° 45° VERTICAL TERMINATION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R +...
Page 13 - OR; INSTALLATION
13 W415-0533 / E / 02.09.06 This application occurswhen venting through aroof. Installation kits forvarious roof pitches areavailable from your Napo-leon dealer. See Accesso-ries to order the specifickit required. 1. Determine the air terminal location, cut and frame 10 inch openings in the ceiling ...
Page 14 - USING FLEXIBLE VENT COMPONENTS
14 W415-0533 / E / 02.09.06 AIR TERMINAL CONNECTOR INNER FLEX LINER OUTER FLEX LINER INNER SLEEVE HIGH TEMPERATURE SEALANT ROOF SUPPORT FIGURE 18 A VENT SHIELD MUST BE USED IF THE WALL TERMINAL ISINSTALLED ON COMBUSTIBLE, EXTERIOR SURFACES. 1. Cut or frame a hole in an exterior wall with a minimum r...
Page 15 - FIREPLACE VENT CONNECTION; USING RIGID VENT COMPONENTS
15 W415-0533 / E / 02.09.06 STORM COLLAR FLASHING CAULKING WEATHER SEALANT 2” AIR INLET BASE FIGURE 25 The vent system must be supported approximately every 3feet for both vertical and horizontal runs. Use Wolf Steelvent spacers every 3 feet and either side of each elbow tomaintain the minimum 1¼...
Page 16 - WIRE SIZE; Continue adding rigid venting sections, sealing and; VERTICAL VENTING INSTALLATION
16 W415-0533 / E / 02.09.06 Vertical terminations may display a very active flame. Asthis appearance is not desirable, the vent exit must berestricted using restrictor plate, W500-0205. This reducesthe velocity of the exhaust gases, slowing down the flamepattern and creating a more traditional appea...
Page 17 - MOBILE HOME INSTALLATION
17 W415-0533 / E / 02.09.06 It is best to frame your fireplace after it is positioned andthe vent system is installed. Use 2x4's and frame to localbuilding codes. FIGURES 31-33. It is not necessary to install a hearth extension with thisfireplace system. When roughing in the fireplace, raise the fir...
Page 18 - NAILING TAB INSTALLATION
18 W415-0533 / E / 02.09.06 NAILING TAB 1) Attach the nailing tabs to the cornerposts using the 2 sheet metal screwssupplied. Secure through the centre ofthe top and bottom slots in the nailingtab and then through the existing holesin the corner posts. If there are no existing holes, followthese ins...
Page 19 - DOOR LATCH; LOWER LOUVRES; L42 LOUVRE INSTALLATION; LOGO; FINISHING; GDL42 LOUVRE INSTALLATION
19 W415-0533 / E / 02.09.06 TO INSTALL THE UPPERLOUVRES: Insert the upper l o u v r e s i n t o t h e s l o t s o nboth brackets. TO INSTALL THE LOWERLOUVRE ASSEMBLY: At- tach each hinge to the fire-box with 2 screws. Position the hinge screeninto place and with the con-trol door open, secure to the...
Page 20 - GLOWING EMBERS; LOG PLACEMENT
20 W415-0533 / E / 02.09.06 3. Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front ofthe small logs (#2 & #3). Care should be taken to shred theembers into thin, small irregular pieces as only the exposededges of the fibre hairs wil...
Page 21 - CHARCOAL EMBERS; OPTIONAL BLOWER INSTALLATION
21 W415-0533 / E / 02.09.06 INSTALLATION TOB E D O N E B Y AQ U A L I F I E D I N -STALLER and mustbe electrically con-n e c t e d a n dgrounded in accord-a n c e w i t h l o c a lc o d e s . I n t h ea b s e n s e o f l o c a lcodes, use the cur-rent CSA C22.1 C A - NADIAN ELECTRICAL CODE i n C a n...
Page 22 - OPTIONAL FAN INSTALLATION
22 W415-0533 / E / 02.09.06 ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-FIED INSTALLER and must be connected and groundedin accordance with local codes. In the absence of localcodes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the U...
Page 23 - OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; MAINTENANCE
23 W415-0533 / E / 02.09.06 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If...
Page 24 - ADJUSTMENTS; PILOT BURNER ADJUSTMENT
24 W415-0533 / E / 02.09.06 Adjust the pilot screw to provide properly sized flame. Turnin a clockwise direction to reduce the gas flow. Air shutters have been factory set open according to thechart below: These settings are for the maximum horizontal vent run.-Adjustment may be required depending o...
Page 25 - REPLACEMENT PARTS; REPLACEMENTS; FLEXIBLE VENT KITS; ACCESSORIES; ROOF TERMINAL KITS
25 W415-0533 / E / 02.09.06 # PART NO. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 W680-0005 THERMOCOUPLE 4 W010-0800 NATURAL GAS PILOT ASSEMBLY 4 W010-0801 PROPANE GAS PILOT ASSEMBLY 5 W455-0069 NATURAL GAS PILOT INJECTOR 5 W455-0067 PROPANE GAS PILOT INJECTOR 6 W725-0025 NATURAL...
Page 27 - TROUBLE SHOOTING GUIDE; SYMPTOM
27 W415-0533 / E / 02.09.06 Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button ignitor.- check if the push button ignitor needs tightening.- replace the wire if the wire insulation is broken or frayed.- replace the electrode if the ceram...