Page 3 - WARNING; • Do not burn wood or other materials in this fireplace.; TABLE of CONTENTS; PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE
WARNING • Do not burn wood or other materials in this fireplace. • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Keep young children and animals away when the fireplace is hot. • Due to high temp...
Page 4 - CONDITIONS AND LIMITATIONS
4 W415-0484 / A / 07.26.06 ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTEREDTRADEMARK OF WOLF STEEL LTD. PATENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL LTD. NAPOLEON NAPOLEON NAPOLEON NAPOLE...
Page 5 - Use only accessories designed for and listed with; GENERAL INSTRUCTIONS
5 W415-0484 / A / 07.23.06 THIS GAS FIREPLACE SHOULD BE INSTALLED AND SERV-ICED BY A QUALIFIED INSTALLER to conform with local codes. In absence of local codes, install the B36DF to the current National Fuel Gas Code, ANSI Z223.1, or the currentCAN/CGA B149, Installation Codes. Installation practice...
Page 6 - FIGURE 1; VENTING; VENTING LENGTHS; Minimum clearance to combustible con-
6 W415-0484 / A / 07.26.06 Use only Wolf Steel, Simpson Dura-Vent, Selkirk DirectTemp or American Metal Amerivent venting components. For Simpson Dura-Vent, Selkirk Direct Temp and AmericanMetal Amerivent, follow the installation procedure providedwith the venting components. All outer pipe joints o...
Page 7 - non; CANADIAN; INSTALLATIONS; AIR TERMINAL LOCATIONS; FIGURE 2
7 W415-0484 / A / 07.23.06 * ** ** Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended to use a heat shield and to maximize the distance to vinyl clad sof fits. * * * * * * * * * * * * * * * The periscope GD-201 requires a minimum 18 inches clear...
Page 8 - FIGURE 4; TYPICAL VENT INSTALLATIONS; Restricting Vertical Vents.
8 W415-0484 / A / 07.26.06 Use the GD401 periscope kit to locate the air terminationabove grade. The periscope must be installed so that whenfinal grading is completed, the bottom air slot is located aminimum of 12 inches above grade. The maximum allow-able vent length depends on the fireplace, as i...
Page 9 - VENTING APPLICATION FLOW CHART
9 W415-0484 / A / 07.23.06 VERTICAL TERMINATION HORIZONTAL TERMINATION Vertical riseis equal to org r e a t e rthan theh o r i z o n t a lrun H o r i z o n t a lrun + verti-c a l r i s e t om a x i m u mof 40 feet Vertical riseis equal to org r e a t e rthan theh o r i z o n t a lrun H o r i z o n t...
Page 10 - HORIZONTAL TERMINATION; REQUIRED
10 W415-0484 / A / 07.26.06 ELBOW VENT LENGTH VALUES DEFINITIONS HORIZONTAL TERMINATION REQUIRED V E R T I C A LRISE IN FEET(V T ) CALCULATED HORIZONTAL VENT RUNPLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) Simple venting configuration (only one 45º and 90° el...
Page 11 - FIGURE 7; FIGURE 8
11 W415-0484 / A / 07.23.06 V 1 HORIZONTAL TERMINATION See graph to determine the re-quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 2...
Page 12 - VERTICAL TERMINATION; FIGURE 9
12 W415-0484 / A / 07.26.06 VERTICAL TERMINATION Example 3: V 1 = 5 ft V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 = 3 ft H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T...
Page 13 - u n a c c e p t a b l e
13 W415-0484 / A / 07.23.06 H 1 VERTICAL TERMINATION For vent configurations requiring more than one 45º andone 90° elbow , the following formulas apply: Formula 1: H T < 3V T Formula 2: H T + V T < 40 feet Example 4: when (H T ) > (V T ) Simple venting configurations See graph to determine...
Page 14 - OR; INSTALLATION
14 W415-0484 / A / 07.26.06 This application occurswhen venting through aroof. Installation kits forvarious roof pitches areavailable from your Napo-leon dealer. See Accesso-ries to order the specifickit required. 1. Determine the air terminal location, cut and frame 10 inch openings in the ceiling ...
Page 15 - USING FLEXIBLE VENT COMPONENTS; DO NOT CLAMP THE FLEXIBLE ALUMINIUM LINER.
15 W415-0484 / A / 07.23.06 INNER FLEX LINER OUTER FLEX LINER INNER SLEEVE HIGH TEMPERATURE SEALANT AIR TERMINAL CONNECTOR FIGURE 18 A VENT SHIELD MUST BE USED IF THE WALL TERMINAL ISINSTALLED ON COMBUSTIBLE, EXTERIOR SURFACES. 1. Cut or frame a hole in an exterior wall with a minimum oval or rectan...
Page 16 - WIRE SIZE; GAS INSTALLATION; not
16 W415-0484 / A / 07.26.06 Vertical terminations may display a very active flame. Asthis appearance is not desirable, the vent exit must berestricted using restrictor plate, W500-0205. This reducesthe velocity of the exhaust gases, slowing down the flamepattern and creating a more traditional appea...
Page 17 - Conversion Kits; MOBILE HOME INSTALLATION
17 W415-0484 / A / 07.23.06 This appliance may be installed as an OEM (OriginalEquipment Manufacturer) installation in a manufacturedhome or mobile home and must be installed in accordancewith the manufacturer’s instructions and the ManufacturedHome Construction and Safety Standard, Title 24 CFR, Pa...
Page 18 - NAILING TAB INSTALLATION
18 W415-0484 / A / 07.26.06 NAILING TAB 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screwssupplied. Secure through the centre ofthe top and bottom slots in the nailingtab and then through the existing holesin the corner posts. If there are no existing holes, followthese in...
Page 19 - FINISHING; L36 LOUVRE INSTALLATION; HOOD
19 W415-0484 / A / 07.23.06 A C B The upper louvres must be removed to allow the door to beopened or closed. To access the lower door latch, openthe valve control door. Release the top and bottom doorlatches, located at the right side of the door. FINISHING L36 LOUVRE INSTALLATION DOOR REMOVAL &...
Page 20 - LOG PLACEMENT; CHARCOAL EMBERS; LOGO
20 W415-0484 / A / 07.26.06 PHAZER TM logs and glowing embers exclusive to Napoleon Fire- places, provide a unique and realistic glowing effect that isdifferent in every installation. Take the time to carefully po-sition the glowing embers for a maximum glowing effect.Log colours may vary. During th...
Page 21 - OPTIONAL BLOWER INSTALLATION
21 W415-0484 / A / 07.23.06 INSTALLATION TO B E D O N E B Y AQ U A L I F I E D I N - S TA L L E R a n dm u s t b e e l e c t r i - cally connected andgrounded in accord-a n c e w i t h l o c a lc o d e s . I n t h ea b s e n s e o f l o c a lcodes, use the cur-rent CSA C22.1 C ANA - DIAN ELECTRICAL ...
Page 22 - OPTIONAL FAN INSTALLATION
22 W415-0484 / A / 07.26.06 ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-FIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of localcodes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the ...
Page 23 - depressed; OPERATION / MAINTENANCE; OPERATING INSTRUCTIONS; MAINTENANCE
23 W415-0484 / A / 07.23.06 • Turn off all gas to the fireplace. • Open windows. • Do not try to light any appliance. • Do not touch any electric switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. • If...
Page 24 - Air shutter adjustment must only be done by a; ADJUSTMENTS; PILOT BURNER ADJUSTMENT; AIR SHUTTER
24 W415-0484 / A / 07.26.06 Adjust the pilot screw to provide properly sized flame. Turnin a clockwise direction to reduce the gas flow. Air shutters have been factory set open according to thechart below: These settings are for the maximum horizontal vent run.-Adjustment may be required depending o...
Page 25 - COMMON REPLACEMENT PARTS:; REPLACEMENTS; FLEXIBLE VENT KITS
25 W415-0484 / A / 07.23.06 COMMON REPLACEMENT PARTS: 37* W175-0166 5" COUPLER 37* W175-0002 8" COUPLER 38 L36K LOUVRE KIT - UPPER & LOWER - BLACK 38 L36PB LOUVRE ASSEMBLY - POLISHED BRASS 38 L36AB LOUVRE ASSEMBLY - ANTIQUE BRASS 38 L36SS LOUVRE ASSEMBLY - BRUSHED STAINLESS STEEL 39* W57...
Page 27 - TROUBLE SHOOTING GUIDE; SYMPTOM
27 W415-0484 / A / 07.23.06 Pilot will not light. - check if pilot can be lit by a match- check that the wire is connected to the push button ignitor.- check if the push button ignitor needs tightening.- replace the wire if the wire insulation is broken or frayed.- replace the electrode if the ceram...
Page 29 - This fireplace must be serviced annually depending on usage.
29 W415-0484 / A / 07.23.06 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T e chnician Name Service Performed Special Concerns Dealer Name
Page 30 - NOTES