Page 2 - INSTALLATION INFORMATION continued; LIQUID COOLED ENGINES:; Consult your engine manual.; Sensing Bulb Mounting Detail; Oil Temperature; Installing the Engine Stop Device; or Alarm; Follow instructions provided with the stop device or alarm.; Electric Wiring; D I S T R I B U TO R I G N I T I O N; For normal stop, pull the manual stop cable.; NOT

WS-93002N page 2 of 7 INSTALLATION INFORMATION continued Connecting High Temperature Swichgage instrument LIQUID COOLED ENGINES: 1. Drain engine coolant to a level below the temperature sensing con- nection/plug. This connection is on the engine side of the thermostatgenerally near the thermostat ho...

Page 3 - Consult the factory if in doubt.; Testing the Swichgage Instruments; This method does NOT test; I f t h e p r e s s u r e S w i c h g a g e i n s t r u m e n t h a s a; TYPICAL WIRING DIAGRAM WITH 117PH MAGNETIC SWITCH

WS-93002N page 3 of 7 Setting the SWICHGAGE ® contacts 1. Face mounted contacts are set using a 1/16 in. hex wrench. 2. Some models such as 20PE, 20TE, etc. may not have field adjust- ment. Consult the factory if in doubt. 3. Observe the “normal operating” oil pressure and coolant tempera- ture read...

Page 4 - 18PH WIRED CLOSED LOOP; TYPICAL WIRING WITH 518PH TATTLETALE CLOSED LOOP

WS-93002N page 4 of 7 R G NC SW1 SW2 B B + GRD SIG Tachometer Hourmeter Voltmeter 518PH 20T-F Temperature 20P-F Pressure _ + _ + To Magnetic Sensor,Alternator “Tach”Terminal, orSignal Generator PB128S Stop Switch To Other Normally Closed Contacts From 518PH WIRED CLOSED LOOP MUST specify 12 or 24 VD...