Page 2 - General connection recommendations; use separate routing for AC and DC wiring harnesses.; Terminal functions; Pin Function; until the Keystart initiates an automatic fault shutdown.; Front view and operation; HIGH VOLTS

Murphy - Keystart 9620 series installation instructions 00-02-0657 revision A 22 nd September 2008 p2/4 Electrical connection to 0.5 to 1.5 mm² / 16 – 20 AW G panel wiring is by spring-clamp terminals at the rear. • pre-strip 8 to 10 mm / 0.3 to 0.4 in. of insulation from each wire. • Above each ter...

Page 3 - remove the DC power supply.; output; Typical connection

Murphy - Keystart 9620 series installation instructions 00-02-0657 revision A 22 nd September 2008 p3/4 Terminal functions (cont.) Pin Function 3 Start (crank) output Pin 3 gives a positive DC, 16 Amp rated output when the key is switched to position II (start/crank). To prolong keyswitch contact li...

Page 4 - Selection of speed signal source: links J2 and J3; links; Speed calibration; Speed calibration is a two stage process:; ) Nominal speed calibration: potentiometer VR2; Start and run the engine to nominal (normal running) speed.; Maintenance and Warranty; Check that all electrical connections are secure.; SPEED SENSING AND CALIBRATION

Murphy - Keystart 9620 series installation instructions 00-02-0657 revision A 22 nd September 2008 p4/4 Keystart model 9621 includes a speed sensing input and automatic shutdown protection for engine overspeed faults. Before use, model 9621’s speed input must be correctly configured (using circuit-b...