Page 2 - If connecting to a Murphy LCDT annunciator refer to Figure 5. See; General Catalog for more information on the LCDT.; DT9805 typical wiring for positive ground ignition; DT9804 typical wiring for negative ground ignition; Ignition; Output Voltage & Polarity of Common CD Ignitions; WARNING; PERFORM THE WIRING INSTALLATION WITH THE POWER SOURCE OFF. DO NOT; PERFORM THE WIRING INSTALLATION WITH THE POWER SOURCE OFF.; (for positive ground

DT9805 1. Connect the magnetic pickup as shown in Figure 3. 2. Connect the overspeed switch wiring as shown Figures 3 and 4. Observe the polarity of the overspeed switch. The positive terminalmust be connected to the positive side of the circuit as shown. 3. If connecting to a Murphy LCDT annunciato...

Page 3 - Calibration; DO NOT USE A PENCIL TO PUSH SWITCHES; CALIBRATING THE DT9800 SERIES TO YOUR ENGINE; Calibration Switch Code; DT9806 typical wiring for negative ground ignition

3 DT9806 Before wiring the DT9806, determine the output voltage and groundpolarity of the ignition. Table 1 lists the Peak Output Voltage and GroundPolarity of some common ignitions. Figure 6 displays wiring to a negative ground ignition and Figure 7 forpositive ground units. If the ignition output ...

Page 4 - the neutral to the negative input. These readings are ±1 RPM.; Dip Switches On; Warranty; Frank W. Murphy Manufacturer

The overspeed set point switches are available on the DT9805 andDT9806 only. The overspeed set point can be set within ± 5 RPM, over arange of 0010 to 9990 RPM. Setting of the overspeed set points is made byproperly adjusting of three rotary switches. Each switch can be adjusted inincrements of ten....