EL150EX SWITCH/TERMINAL KIT
INSTALLATION INSTRUCTIONS

EL150EX-04033N

Effective 02-04

Section 15

00-02-0564

Installation

1

. Place screws in terminal block mounting holes and fasten to

the cover as shown in Figure 1.

2

. Place clear plastic insulator behind microswitch and insert

screws through microswitch mounting holes.

3

. Place microswitch assembly inside the cover and tighten

screws as shown in Figure 1. Make sure that all wires are placed
along the left side of the cover and that they do not interfere with
the operation of the unit.

4.

Calibrate the microswitch by holding the microswitch arm

down and bending the end of the arm up with needle nose pliers.
(See Figure 2)

5

. Hold the unit in hand, and move the float down while listening

for the microswitch to “click”. Microswitch should “click” when
pointer is between the

L

and

O

in the word

LOW

as shown in

Figure 2.

6

. Repeat steps 4 & 5 until microswitch “clicks” at the correct

location.

Please read the following information before installing

.

A visual inspection of this product for damage during shipping is rec-

ommended before mounting. It is your responsibility to have a qualified person install this unit and make sure it conforms to NEC
and local codes.

GENERAL INFORMATION

WARNING

BEFORE BEGINNING INSTALLATION OF THIS MURPHY PRODUCT

Disconnect all electrical power to the machine.

Make sure the machine cannot operate during installation.

Follow all safety warnings of the machine manufacturer.

Read and follow all installation instructions.

CONTROL SYSTEMS & SERVICES DIVISION

P.O. Box 1819; Rosenberg, Texas 77471; USA
+1 281 633 4500 fax +1 281 633 4588
e-mail [email protected]

MURPHY DE MEXICO, S.A. DE C.V.

Blvd. Antonio Rocha Cordero 300, Fracción del Aguaje
San Luis Potosí, S.L.P.; México 78384
+52 444 8206264 fax +52 444 8206336
Villahermosa Office +52 993 3162117

e-mail

[email protected]

www.murphymex.com.mx

INDUSTRIAL PANEL DIVISION

P.O. Box 470248
Tulsa, Oklahoma 74147 USA
+1 918 317 4100

fax

+1 918 317 4266

e-mail

[email protected]

www.fwmurphy.com

FRANK W. MURPHY, LTD.

Church Rd.; Laverstock, Salisbury SP1 1QZ; U.K.
+44 1722 410055 fax +44 1722 410088
e-mail [email protected]
www.fwmurphy.co.uk

In order to consistently bring you the highest quality, full featured products, we reserve the right to change our specifications and designs at any time.

FW Murphy

P.O. Box 470248
Tulsa, Oklahoma 74147 USA
+1 918 317 4100

fax

+1 918 317 4266

e-mail

[email protected]

www.

fwmurphy

.com

R

E

G I S T E R E

D

USA–ISO 9001:2000 FM 28221

UK–ISO 9001:2000 FM 29422

Printed in U.S.A.

Warranty

A limited warranty on materials and workmanship is given with this FW Murphy product. A copy of the warranty may be

viewed or printed by going to www.fwmurphy.com/support/warranty.htm

Figure 1.

Complete Installation of Switch/Terminal Kit

Figure 2.

Example of Correct Calibration