Page 2 - EYF Series Unvented Gas Log Set; CONTENTS
65D1009 EYF Series Unvented Gas Log Set CONTENTS Important Safety Information ......................................3Getting Started ..............................................................5 Codes .......................................................................7 Product Features and Spe...
Page 3 - IMPORTANT SAFETY INFORMATION; Any change to this heater or its controls can be dangerous.; Vented Instructions; CARBON MONOXIDE POISONING:
3 65D1009 EYF Series Unvented Gas Log Set IMPORTANT SAFETY INFORMATION INSTALLER Please leave these instructions with the appliance. OWNER Please retain these instructions for future reference. W ARNING • Any change to this heater or its controls can be dangerous. • Improper installation or use of t...
Page 4 - CODES
65D1009 4 EYF Series Unvented Gas Log Set IMPORTANT SAFETY INFORMATION 16. Keep room area clear and free from combustible materials, gasoline and other flammable vapors and liquids. 17. Unvented gas heaters are a supplemental zone heater. They are not intended to be a primary heating appli-ance. Wat...
Page 5 - ARNING; Control; IGNITION CONTROLS
5 65D1009 EYF Series Unvented Gas Log Set W ARNING • G l o v e s a r e r e c o m m e n d e d w h e n handling ceramic fiber logs to prevent skin irritation from loose fibers. • Logs are fragile - handle with care. MAkE SURE YOU HAVE RECEIVED ALL PARTS: Check your packing list to verify that all list...
Page 6 - INSTALLATION INFORMATION; defines a confined space as a space; UNUSUALLy TIGhT CONSTRUCTION IS DEfINED AS CONSTRUCTION WhERE:; ) or less with openings gasketed or sealed
65D1009 6 EYF Series Unvented Gas Log Set INSTALLATION INFORMATION ADEQUATE COMBUSTION AND VENTILATION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The National Fuel Gas Code, (A...
Page 7 - FIREPLACE and HEARTH DIMENSIONS; DO NOT install this appliance in a factory-built fireplace that; Model; Height of
7 65D1009 EYF Series Unvented Gas Log Set FIREPLACE and HEARTH DIMENSIONS W ARNING This appliance has been specifically tested and design certified for installation only in a solid-fuel burning fireplace including factory-built UL127 fireplaces and masonry fireplaces, or in a listed ventless firebox...
Page 8 - INSTALLATION; The dimensions shown in; Figures 4 through 10; and defined in the fireplace; sides
65D1009 8 EYF Series Unvented Gas Log Set INSTALLATION The dimensions shown in Figures 4 through 10 and defined in the fireplace manufacturer's instructions are minimum clearances to maintain when installing this heater. Left and right clearances are determined when facing the front of the heater.Wh...
Page 9 - Figure 6; Min
9 65D1009 EYF Series Unvented Gas Log Set INSTALLATION Heat resistant material (minimum requirements) with wooden mantel or other combustible projection: To install the heater with a wooden mantel, shelf or other combustible projection above, first measure the heat resistant material shown in Figure...
Page 10 - Figure 9; OR; Turn; OFF; the gas supply to the fireplace or firebox.; Do not seal the chimney flue; Turn off gas supply to fireplace or firebox.; DO NOT install this appliance
65D1009 10 EYF Series Unvented Gas Log Set INSTALLATION The gas log heater must be installed at least 5" above any combustible flooring material, such as carpeting or tile, which is closer than 14" to the base of the fireplace. The minimum distance must be maintained from the top surface of ...
Page 11 - to prevent full closure of the fireplace; Insert longest middle grate bar in one; Placement in
11 65D1009 EYF Series Unvented Gas Log Set INSTALLATION DAMPER STOP INSTALLATION: A damper stop must be provided with the unit. Contact your dealer to obtain one. The damper stop must be installed as shown in Figure 11 to prevent full closure of the fireplace damper blade and provide a minimum 9 squ...
Page 12 - GAS LINE CONNECTION; MILLIVOLT CONTROL
65D1009 1 EYF Series Unvented Gas Log Set NOTICE: A qualified gas appliance installer must connect the heater to the gas supply. Consult all local codes. IMPORTANT: Hold heater valve firmly with a wrench to prevent movement when connecting to inlet pipe. Always use an external regulator for all prop...
Page 13 - ELECTRICAL WIRING - MILLIVOLT; CONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT
13 65D1009 EYF Series Unvented Gas Log Set ELECTRICAL WIRING - MILLIVOLT Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. W ARNING FP2112wiring diagram12/08 Wall Switch On/Off Switch On/...
Page 15 - Before you begin; — This unit is supplied with a four; Always wear gloves to prevent skin; After handling the log unit,; INSTALL EYF24-F LOG UNIT ON BURNER; PLACE THE DECORATIVE ROCk
15 65D1009 EYF Series Unvented Gas Log Set W ARNING LOG PLACEMENT The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishm...
Page 16 - LOG PLACEMENT; Figure
65D1009 16 EYF Series Unvented Gas Log Set LOG PLACEMENT PLACE EYF18-R LOGS 1. Place Rear Log (#1) on rear support. Figure 19 . Place Middle Log (#) on middle support. Figure 20 3. Place Front Log (#3) in between burner and grate. Figure 21 4. Rest Top Log (#4) in front and middle log cutouts. Figur...
Page 18 - FLAME APPEARANCE; It should just; Correct Pilot Flame Appearance
65D1009 18 EYF Series Unvented Gas Log Set FLAME APPEARANCE FP2501manual pilot flame FP2273pilot bad flame FP2272pilot correct flame Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during ...
Page 19 - not; OPERATING INSTRUCTIONS; Avoid any drafts that alter burner flame patterns.; Do not allow fans to blow directly into the
19 65D1009 EYF Series Unvented Gas Log Set FLAME APPEARANCE In normal operation at full rate after 15 minutes, the following flame appearances should be observed: The left and right flames should be yellow and extend 1" to " above the log top surfaces. The yellow flames should not contact th...
Page 20 - FOR YOUR SAFETY, READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS:; Do not attempt to light any appliance.
65D1009 0 EYF Series Unvented Gas Log Set FOR YOUR SAFETY, READ BEFORE LIGHTING A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand. B. BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to...
Page 21 - MANUAL CONTROL LIGhTING INSTRUCTIONS; Refer to Page 22, Figure 37; TO TURN Off GAS TO hEATER
1 65D1009 EYF Series Unvented Gas Log Set OPERATING INSTRUCTIONS MANUAL CONTROL LIGhTING INSTRUCTIONS 1. STOP! Read the safety information. . Make sure the manual shutoff valve is fully open.3. This heater is equipped with an ignition device (piezo) which automatically lights the pilot. 4. Refer to ...
Page 22 - MILLIVOLT CONTROL LIGHTING INSTRUCTIONS; Match Lighting Instructions, Page 26; TO TURN OFF GAS TO HEATER
65D1009 EYF Series Unvented Gas Log Set OPERATING INSTRUCTIONS MILLIVOLT CONTROL LIGHTING INSTRUCTIONS 1. STOP! Read the safety information label. . Make sure the manual shutoff valve is fully open.3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. ...
Page 23 - OPERATING INSTRUCTIONS and MAINTENANCE; MATCh LIGhTING INSTRUCTIONS; for correct log placement.; PERIODIC CLEANING; - Refer to the parts diagram for location of items discussed; Do not use cleaning fluid to clean logs or any part of heater.; ANNUAL CLEANING/INSPECTION; - Refer to the parts diagram for location of; Inspect and clean all burner ports.
3 65D1009 EYF Series Unvented Gas Log Set OPERATING INSTRUCTIONS and MAINTENANCE MATCh LIGhTING INSTRUCTIONS 1. Remove any items necessary for easy access to the pilot (for example: logs, screens, etc.).. Follow appropriate lighting instructions found previously. Instead of pushing and releasing the...
Page 24 - TROUBLESHOOTING
65D1009 4 EYF Series Unvented Gas Log Set TROUBLESHOOTING W ARNING Turn off appliance and allow to cool before cleaning. Only a qualified service person should service and reapir the heater. NOTE: All troubleshooting items are listed in order of operation. Problem When ignitor button is pressed, the...
Page 26 - REPLACEMENT PARTS; Description
65D1009 6 EYF Series Unvented Gas Log Set REPLACEMENT PARTS W ARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved w i t h t h i s a p p l i a n c e m a y result in property damage or personal injury. 1 4 7 - Manual 11 2 3 5 9 6 1...
Page 30 - NOTE REGARDING VENTED PRODUCTS
65D1009 30 EYF Series Unvented Gas Log Set NOTE REGARDING VENTED PRODUCTS This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachusetts.Any residence with a direct vent product must have a CO detector installed in the residence.Installatio...
Page 31 - What is covered and for How Long; Logs; within 10 years of the verified purchase date.; All Other Parts; What is Not Covered; on the date the heater/decorative gas appliance was manufactured.; Gas Logs Limited Warranty
What is covered and for How Long MHSC will make available replacement parts for parts that are defective according to the following terms. Logs - A free replacement will be made available at our factory for any logs if they fail due to deterioration within two () years of the verified purchase. Stee...
Page 32 - MHSC
MHSC 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com