Page 2 - 24WBPF Woodburning Fireplace; listing and code approvals; table of contents; listed by oMNi-test laboratories to; coNteNtS
2 624WBPF Woodburning Fireplace 53D9052 You have chosen the finest wood burning fireplace available. Your fireplace has been designed for years of heating and viewing enjoyment. Please take time to read this entire manual before installing or operating your fireplace. listing and code approvals The ...
Page 3 - proper operation and maintenance.; intended Product usage
3 53D9052 624WBPF Woodburning Fireplace 1. Read these instructions entirely before beginning any part of the installation. Save these instructions for any future repairs. 2. Use these instructions as a guide during the installation of the fireplace.3. Be sure these instructions become the property o...
Page 4 - Page; Note; oPeratioN guideliNeS
4 624WBPF Woodburning Fireplace 53D9052 When an AK4 combustion air assembly and a combustion air duct are attached to the connecting point on the left or right side of the fireplace, combustion air may enter the firebox through a dam-pered opening behind the left or right side brick. This feature is...
Page 5 - Figure 1; FirePlace diMeNSioNS
5 53D9052 624WBPF Woodburning Fireplace 36 56O ” (927 mm) 1/2” (13 mm) 30 56M ” (768 mm) 37 56M ” (946 mm) 42” (1067 mm) 45 6M ” (1162 mm) 36” (914 mm)38” (965 mm) 23” (584 mm) 1/2” (13 mm) 14 (6 ” (378 mm) 8 56O ” (216 mm) 12” (305 mm) 24” (610 mm) 22 6M ” (578 mm) 9” (229 mm) 12” (305 mm) 53904...
Page 6 - FirePlace locatioN; as guides for selecting a location and determining the; cautio
6 624WBPF Woodburning Fireplace 53D9052 FirePlace locatioN This fireplace does not require any special foundation. If the fireplace is to be trimmed with large stone or brick facing, an adequate foundation is required to support these materials. Refer to Figures 1-5 as guides for selecting a locatio...
Page 7 - clearaNceS; ote
7 53D9052 624WBPF Woodburning Fireplace clearaNceS FP2345MPL features Figure 3Residential Installation Chimney Cap Roof Flashing (Flue Outlet Height) Storm Collar 14 ft. = Min. Height (No offsets)14 ft. = Min. Height (2 30° Elbows)21 ft. = Min. Height (4 30° Elbows)86 ft. = Max. Height (Chimney supp...
Page 8 - iNStallatioN PreParatioN; Single Story installation with attic Space; Figure 4; Multiple Story installation
8 624WBPF Woodburning Fireplace 53D9052 Survey the planned location for the fireplace for overhead plumbing or electrical wires, etc., that might complicate the installation or endanger persons installing or cleaning the chimney. Avoid a location where the chimney cap will be near abrupt changes in ...
Page 9 - Floor ProtectioN; Figure 8; Figure 6; Figure 7
9 53D9052 624WBPF Woodburning Fireplace Floor ProtectioN If this fireplace is installed on a combustible floor, the floor area 16 inches in front of, and 8 inches ei-ther side of the fireplace opening must be protected by an insulating noncombustible hearth extension. Figures 6 & 7 With either t...
Page 10 - Model Number; FirePlace coMPoNeNtS
10 624WBPF Woodburning Fireplace 53D9052 WH36 Glass Doors (Standard) Chimney Support11CS 30° Elbow Set 11CF30-2 Hearth Extension KitH1652 Firestop SpacerFS2A, FS6A Flashing 8-6-12, 8-12-12 AK4 Combustion Air Assembly (AK6 for Manufactured Home Installation) Chimney Cap RLTCF11SLTCF11 ...
Page 11 - location Selection; Figure 3; chimney installation; debris into the chimney and to assure the proper venting of smoke.; FirePlace iNStallatioN; Flue outlet should be 24” above all; RLTSKC8
11 53D9052 624WBPF Woodburning Fireplace location Selection Unpack and check the fireplace and chimney for damage. If any items have been damaged, report this to your dealer. Before beginning the installation, be sure you have the proper parts in sufficient quantity. Refer to replacement parts page ...
Page 12 - chiMNey iNStallatioN; Angle of Chimney at Ceiling; CHIMNEY HOLE SIZE; Firestop Spacer
12 624WBPF Woodburning Fireplace 53D9052 chiMNey iNStallatioN FP 548b SHR 5/11/99 djt Angle of Chimney at Ceiling Size of Chimney Vertical 30˚ 11" CF 2-Wall FS2A 17 56O " x 17 56O " (445 x 445 mm) FS6A 17 (6 " x 29 6 " (454 x 753 mm) CHIMNEY HOLE SIZE table 1 18 56O ” (470 mm) CL...
Page 14 - offset installation Sequence; and elbows required from the offset chart.; chiMNey oFFSet iNStallatioN
14 624WBPF Woodburning Fireplace 53D9052 offset installation Sequence 1. Determine the location and amount of offset required, then select the combinations of chimney sections and elbows required from the offset chart. Refer to Page 15 . 2. Install the first elbow by placing the extended flue into t...
Page 15 - chimney requirements - offset installations; illustration key; Offset
15 53D9052 624WBPF Woodburning Fireplace chimney requirements - offset installations 0 0 0 0 0 3" 11" 1 0 0 0 0 8 Z\₄ " 20" 0 1 0 0 0 11 Z\₄ " 25 Z\₄ " 2 0 0 0 0 13 Z\x " 29 Z\₄ " 1 1 0 0 0 16 Z\x " 34 Z\₄ " 0 0 1 0 0 20 Z\₄ " 40 ³\₄ " 2 1 0 0 0 21 ³\₄...
Page 16 - chiMNey caP iNStallatioN
16 624WBPF Woodburning Fireplace 53D9052 chiMNey caP iNStallatioN Note: The proper height as previously explained is important to assure proper draft and safety. The chim- ney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when deter...
Page 17 - part of the flashing under the shingles.
17 53D9052 624WBPF Woodburning Fireplace chiMNey caP iNStallatioN 1. Extend the regular chimney sections until the top of the chimney is 4” below the total flue height desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is completed. 2. Remove the s...
Page 18 - outside combustion air recommendations
18 624WBPF Woodburning Fireplace 53D9052 outside combustion air recommendations (continued) 1. Extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly should be avoided. These conditions will increase the resistance to the free flow of air through...
Page 19 - outSide coMBuStioN air
19 53D9052 624WBPF Woodburning Fireplace outSide coMBuStioN air 1 2 3 2“ App. FP1906 Duct connector 8/08 Loop Disengaged Clamp Around Duct Slip Band Through Housing Snap Screw Down and Tighten Figure 23 FP1906 installing Model 403 duct connector 1. Push insulation back approximately 2...
Page 20 - gaS aPPliaNce iNStallatioN; operated with the fireplace glass door fully open (if included).
20 624WBPF Woodburning Fireplace 53D9052 gaS aPPliaNce iNStallatioN WarNiNg: Improper installation or operation of a gas appliance in this fireplace can allow unburned gas to leak out which will cause a fire or explosion hazard, or the release of poisonous carbon monoxide into the dwelling which can...
Page 21 - gaS aPPliaNce; gas line Plumbing detail
21 53D9052 624WBPF Woodburning Fireplace gaS aPPliaNce FP2356gas line installation 4” cautioN: When using a gas appliance, the fireplace damper must be set in fully open position. Figure 26 Outer Fireplace Wrap Inner Fireplace Wrap Side Brick 24” Max. Fireplace Firebox Hearth Brick Gas Line Access T...
Page 22 - Fireplace; triM iNStallatioN; glaSS door iNStallatioN
22 624WBPF Woodburning Fireplace 53D9052 FP2358finish install 1/2” Min. Air Space to Combustibles Fireplace 2 x 4 Stud Wallboard Corner Post Nailing Flange FP2358 Figure 27 triM iNStallatioN decorative triM iNStallatioN Do not allow the trim materials to extend closer than 3/8 inch to the vertical e...
Page 23 - FirePlace oPeratioN; This appliance is not for use as cooking equipment.; Which Woods are Best?
23 53D9052 624WBPF Woodburning Fireplace FirePlace oPeratioN WarNiNg: If a decorative gas appliance is used in the fireplace the fireplace damper must be fixed in an open position. (See additional operation information in section titled “Operation Guide-lines”.) advantages of a Wood Burning Fireplac...
Page 25 - Fuel Storage
25 53D9052 624WBPF Woodburning Fireplace MaiNteNaNce & SaFety Fuel Storage Wood can be dried sufficiently for burning within a few weeks if protected form rain in a low humid-ity area. It is far better to cut wood and allow it to dry for a year. In all cases, the wood should be stacked so that b...
Page 26 - Fireplace Maintenance; do’S; poses to prevent contact with and possible damage to the chimney.
26 624WBPF Woodburning Fireplace 53D9052 Fireplace Maintenance At the end of each heating season or when the fireplace will not be in use for an extended time, the ashes should be removed and the hearth area should be swept as clean as is practical. The slow absorption of moisture into the ashes ove...
Page 27 - doNt’S; prevent it from shifting out of position.
27 53D9052 624WBPF Woodburning Fireplace MaiNteNaNce & SaFety doNt’S 1. Don’t allow other installations or operation considerations to take priority over safety considerations.2. Don’t attempt to use the fireplace until the installation is complete.3. Don’t use unlisted parts and accessories wit...
Page 28 - rePlaceMeNt PartS; description; Air Door Rod
28 624WBPF Woodburning Fireplace 53D9052 rePlaceMeNt PartS 1 2 3 4 5 6 7a,b,c 8 9 10 11 12 13a,b,c 1 11 539042MPL parts ref. description qty. Part No. 1. Panel, Front Ptd. Assy. 4 042988 2. Panel, End Ptd.Assy. 1 042990 3. Panel, End Vented Ptd. Assy. 1 043006 4. Post, Corner Ptd. Assy. 4 043008 5. ...
Page 31 - Factory-Built FirePlace aNd coMPoNeNtS; liMited WarraNty; twenty-Five-year availability of replacement Parts; What is Not covered
31 53D9052 624WBPF Woodburning Fireplace Factory-Built FirePlace aNd coMPoNeNtS (except blowers) liMited WarraNty What is covered and For how long • Five-year coverage - For five years from the date this fireplace and components are first purchased for use, MHSC will, at its option, repair or replac...
Page 32 - MhSc
APRIL 2009 53D9042 • Rev. 3 MhSc 149 Cleveland Drive • Paris, Kentucky 40361 www.mhsc.com