Summary

Page 4 - Coil frost prevention; MS MICROPROCESSOR CONTROL

4 1-1. COOL ( ) OPERATION 2. Indoor fan speed control Indoor fan operates continuously at the set speed by FAN SPEED CONTROL button regardless of the thermostat's OFF- ON. In AUTO the fan speed is as follows. 1. Thermostat control Thermostat turns ON or OFF by the difference between room temperature...

Page 7 - Indoor fan speed control; In AUTO the fan speed is as follows.; Thermostat control; The indoor fan maintains the actual speed of the moment.; Low outside temperature operation; door fan rotation does not stop.; MSZ, MSY MICROPROCESSOR CONTROL

7 2-1. COOL ( ) OPERATION 2. Indoor fan speed control Indoor fan operates continuously at the set speed by FAN SPEED CONTROL button regardless of the thermostat's OFF- ON. In AUTO the fan speed is as follows. 1. Thermostat control Thermostat turns ON or OFF by the difference between room temperature...

Page 9 - Gradation of fan speed in initial

9 (2) Cold air prevention control MSZ-A09/12/15/17 MSZ-FD MSZ-FE MSZ-D MSZ-GE When the compressor is not operating, ( ) if the temperature of room temperature thermistor is less than 66°F (19°C), the fan stops. ( ) if the temperature of room temperature thermistor is 66°F (19°C) or more and ( ) if t...