Page 2 - Micro Inverter
3 2 -15˚C +43˚C -20˚C +20˚C 50 40 30 20 10 0 -10 -20 -30 Heating Cooling : Heating operation down to -20˚C: Nominal heating capacity maintained at -15˚C -20˚C -15˚C FDC100VSX(4HP, 3phase 380V)FDC125VSX(5HP, 3phase 380V)FDC140VSX(6HP, 3phase 380V) Micro Inverter Hyper Inverter 12.516.016.5 16.018.020...
Page 4 - FDU; and Transparent inspection window.; FDUM
5 4 Previous New Due to optimization of outlet design of air flow with our new advanced technology, sufficient air flow is secured and long reach of air flow is realized. (FDT) For person who is far from the indoor unit For both persons who are feeling hot or cold Can cool both the kitchen and the g...
Page 6 - OUTDOOR UNIT
7 6 SINGLE [OUTDOOR UNIT : INDOOR UNIT = 1 : 1] CEILING SUSPENDED WALL MOUNTED Type 4way FDT 4way compact (600 x 600mm) FDTC Low/Middle Static pressure FDUM High Static pressure FDU FDEN SRK CEILING CASSETTE DUCT CONNECTED FDTC40ZMXVF FDTC50ZMXVF FDTC60ZMXVF FDTC40VF FDTC50VF FDTC60VF SRC40ZMX-S SRC...
Page 8 - FDT; Easy checking of drain pan; Arrangement of installation
9 8 FDT CEILING CASSETTE -4way- Dimensions (Unit:mm) R410A Easy checking of drain pan condition is available by removing corner lid only. Due to new design changing fan motor is available without removing a panel. Temporally setting of drain pan is also available. Point 2 Easy checking of drain pan ...
Page 10 - FDTC; “CLEARER”Air Flow; Installation Workability; Compact and Convenient; Quiet operation
11 10 FDTC R410A CEILING CASSETTE -4way Compact (600 X 600mm)- Point 3 “CLEARER”Air Flow Point 4 Installation Workability SPECIFICATIONS The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, ...
Page 12 - Quiet, Lightweight and Compact; Enhanced installation workability
12 13 Quiet, Lightweight and Compact With the FDU71, the noise level is only 25dB (low), weight is only 34kg and height is only 280mm. In addition 600mm Drain Pump is mounted in FDU71/100/125/140.The indoor unit is completely hidden in the ceiling, so this is suitable for spaces with classy interior...
Page 16 - Increased freedom of a piping layout; Improved installation workability; Compact and modern design; FDEN; CEILING SUSPENDED
17 16 Dimensions (Unit:mm) model FDEN40,50 FDEN60,71 FDEN100~140 a 1022 1272 1572 b 990 1240 1540 c 1070 1320 1620 d 215 215 255 e 210 210 250 Dimension Table 68 410 690 135 145 271 235 109 53 195 52 290 (Suspension bolts pitch) Holes for suspension bolts (M8 to M10x4pcs.Not included) Liquid piping ...
Page 18 - Wide and powerful air flow; FDF; FLOOR STANDING; Easy Transportation and Installation workability
19 18 Dimensions (Unit:mm) R410A Piping and drain hose connection can be selected out of 4-directions and the selection makes installation workability more effective.Due to slim design (Depth: 320mm), easy transportation and installation are realized. Easy Maintenance The surface of heat exchanger c...
Page 24 - Installation workability; in the industry and precharged refrigerant.; Piping length – 100m; Refrigerant precharged piping length extending to 30m
25 24 R410A RCN-KIT3-E Wireless remote control (Option) Dimensions : refer to page 18 FDC200VS (8.0HP) FDC71VNX (3.0HP) FDC250VS (10.0HP) FDC71VNP (3.0HP) FDC90VNP (3.5HP) OUTDOOR UNIT (1.5-10.0HP) Installation workability Enhanced installation workability thanks to the extended pipe length – longes...
Page 26 - CEILING CASSETTE DUCT CONNECTED
27 26 Standard Inverter [ INDOOR UNIT ] 4way FDT Low/Middle Static pressure FDUM High Static pressure FDU FDEN FDF Wired RC-E5 RCH-E3 RC-EX1A Remote control (Option) Wireless RCN-KIT3-E (For FDU, FDUM, FDF) RCN-E1R (For FDEN) RCN-TC-36W-E (For FDT) Filter kit (option) UM-FL2EF : for 71 UM-FL3EF : fo...
Page 28 - MULTI SYSTEM; Decision of piping specification; Up to Four indoor units can be connected; By referring to the following table for applicable indoor units,; V Multi System; Twin type; Triple type
29 28 MULTI SYSTEM Outdoor unit Indoor unit L Liquid line Gas line 1 2 3 3 4 4 40 50 60 71 100 125 FDC71VNX Outdoor Unit Twin Triple FDC100VNX FDC100VSX FDC125VNX FDC125VSX FDC140VNX FDC140VSX FDC100VN FDC100VS FDC125VN FDC125VS FDC140VN FDC140VS FDC200VS FDC250VS 40 + 40 50 + 50 60 + 60 50 + 71 71 ...
Page 38 - Jet Air Scroll; SRK; WALL MOUNTED; Long Reach Air Flow
39 38 SRK 50/60 R410A We used the same aerodynamic analysis technology as used in developing jet engines. Point 1 Jet Air Scroll SPECIFICATIONS The data are measured under the following conditions (ISO-T1). Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of ...
Page 40 - Consideration on the Environment; All models employ R410A, with RoHS* directive; Convenience; Monitoring Function; Employment of lead-free solder; RoHS:Restriction of Hazardous substances; ENERGY LABEL
41 40 RCN-KIT3-E Wireless remote control (Option) FDF FLOOR STANDING R410A SPECIFICATIONS The values are for simultaneous Multi operation. MULTI [ INDOOR UNIT ] The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:...
Page 42 - Control System
43 42 Up to 96 cells (some cells can have two or more indoor units and total number of indoor units can be up to 128 units) are controlled from the Internet Explorer. In case of SC-BGWNA256-A/B, up to 256 cells (some cells can have two or more indoor units and total number of indoor units can be up ...
Page 44 - Main functions; Simple setting REMOTE CONTROL; Advanced touch screen panel with full dot Liquid Crystal display; All settings done by tapping touch screen panel; Simple setting by tapping button only; User friendly; Saving energy; High level of visibility; •Big LCD with 3.8 inch full dot display; Operation mode; Basic operation; The highest capacity operation; High power operation; •Changes set temperature.; Energy-saving operation
45 44 Main functions Simple setting REMOTE CONTROL (Option) Simple setting REMOTE CONTROL (Option) Advanced touch screen panel with full dot Liquid Crystal display All settings done by tapping touch screen panel Simple setting by tapping button only RC-EX1A Operation mode setting screen The desired ...
Page 46 - Wired remote control with weekly timer (option); Remote Control line up
47 46 indoor unit remote control wired all models RC-E5 RCH-E3 RC-EX1A FOR EU/EEA AREA ONLY Wired remote control with weekly timer (option) RC-E5 stores operation data when an anomaly occurs and indicates the error on the LCD. It also displays cumulative operation hours of the air conditioner and co...
Page 48 - OUTDOOR UNIT DIMENSIONS
49 48 OUTDOOR UNIT DIMENSIONS (unit:mm) FDC100VN, 125VN, 140VN 100VS, 125VS, 140VS Mark A BC D E F Item Refrigerant gas side pipe connection tap Refrigerant liquid side pipe connection tap Pipe/cable draw-out port Drain discharge port Anchor bolt hole Cable draw-out port ø15.88(flare) ø9.52(flare) ø...