Page 2 - SAFETY PRECAUTIONS; Depending on circumstances, procedures indicated by; CAUTION; may also; DANGER; Some failures of the GOT main unit, communication module,
A-1 DANGER CAUTION z SAFETY PRECAUTIONS z (Read these precautions before using.) When using this equipment, thoroughly read this manual. Also pay carefulattention to safety and handle the module properly.These precautions apply only to this equipment.Refer to the user’s manual of the CPU module to u...
Page 3 - even if the screensaver is set.
A-2 [DESIGN PRECAUTIONS] DANGER z Do not use the GOT as the warning device that may cause a seriousaccident.An independent and redundant hardware or mechanical interlock is requiredto configure the device that displays and outputs serious warning.Failure to observe this instruction may result in an ...
Page 4 - The GOT should be used in the environment given in the general
A-3 [MOUNTING PRECAUTIONS] CAUTION z The GOT should be used in the environment given in the general specifications of this user's manual.Not doing so can cause an electric shock, fire, malfunction or productdamage or deterioration. z When mounting the GOT main unit to an enclosure, tighten the mount...
Page 5 - Please make sure to ground FG terminal, LG terminal, and protective
A-4 [WIRING PRECAUTIONS] CAUTION z Please make sure to ground FG terminal, LG terminal, and protective ground terminal of the GOT power supply unit by applying Class DGrounding (Class 3 Grounding Method) or higher which is used exclusivelyfor the GOT.Not doing so may cause an electric shock or malfu...
Page 6 - When power is on, do not touch the terminals.; Do not disassemble or modify the module.
A-5 [STARTUP/MAINTENANCE PRECAUTIONS] DANGER z When power is on, do not touch the terminals. Doing so can cause an electric shock or malfunction. z Before starting cleaning or terminal screw retightening, always switch off the power externally in all phases.Not switching the power off in all phases ...
Page 7 - When changing the backlight, always note the following.; When disposing of the product, handle it as industrial waste.
A-6 [BACKLIGHT CHANGING PRECAUTIONS] DANGER z Before changing the backlight, always switch off the GOT power externally in all phases (when the GOT is connected to the bus, the PLC CPU powermust also be switched off externally in all phases) and remove the GOTmain unit from the enclosure.Not switchi...
Page 8 - Revisions; *The manual number is given on the bottom right of the top cover.
A-7 Revisions *The manual number is given on the bottom right of the top cover. Print Date *Manual Number Revision Jan., 1999 IB(NA)-80032-A First edition Jun., 1999 IB(NA)-80032-B Partial correction Section 5.1 Partial addition Section 3.2, Section 3.3, Section 5.2 Addition A970GOT-LBA/LBD Jun., 20...
Page 9 - CONTENTS; About Manuals; Detailed Manual
A-8 CONTENTS 1. Overview ....................................................................................................... 1 1.1 Packing List .............................................................................................. 1 2. System Configuration ..................................
Page 11 - System Configuration; The overall configuration of the GOT is shown below.; GOT
2 2. System Configuration The overall configuration of the GOT is shown below. GOT Communication module, Communication board *1 Drawing software Option Memory board Flash PC card *1 External I/O interface module *1 Backlight Protective sheet Debug stand Others Audio output device (Commercially avail...
Page 12 - General specifications; *4: Please do not use or store GOT in an environment with atmospheric
3 3. Specifications 3.1 General specifications Item Specifications Display section 0 to 40 ° C *1 Operatingambienttemperature Other than display section 0 to 55 ° C Storage ambienttemperature -20 to 60 ° C Operatingambient humidity 10 to 90%RH, non-condensing Storage ambienthumidity 10 to 90%RH, non...
Page 13 - Performance specifications; service life of the back light.
4 3.2 Performance specifications Specifications Item A975GOT- TBA(-B) A975GOT- TBD(-B) A970GOT- TBA(-B) A970GOT- TBD(-B) A970GOT- SBA A970GOT- SBD A970GOT-LBA A970GOT-LBD A960GOT-EBA A960GOT-EBD Type TFT color liquid crystal D-STN color liquid crystal STN monochrome liquid crystal EL Resolution 640 ...
Page 14 - (1) Specification differences by the version of GOT
5 *4: GT Works2 and GT Designer2, are supported from the first version (Version1.00A). *5: The specifications differ depending on the version of GOT (hardware version, function version). (1) Specification differences by the version of GOT The specifications of the GOT-A900 series differ depending on...
Page 15 - Power supply specifications; A960GOT User’s Manual that is to be purchased separately.
6 3.3 Power supply specifications Specifications Item A975GOT-TBA(-B)A970GOT-TBA(-B) A970GOT-SBA A970GOT-LBA A960GOT-EBA A975GOT-TBD(-B)A970GOT-TBD(-B) A970GOT-SBD A970GOT-LBD A960GOT-EBD Input power supplyvoltage 100AC to 240V ( + 10%,-15%) 24VDC( + 25%,-20%) Input frequency [Hz] 50/60 ± 3 - Input ...
Page 16 - Name of the Parts
7 4. Name of the Parts 1) 2) 3) 4) 5) 6) 7) 13) 12) 11) 10) 9) 8) 17) 17) 17) 17) 18) When 9) is removed 14) 16) 15) No. Name Description 1) Display section Shows the screen 2) Reset button Used to reset the hardware of the GOT 3) memory card access switch Used to set the condition of access to the ...
Page 17 - Handling instructions; Installation method
8 5. Handling 5.1 Handling instructions When mounting the main unit to a control box or the like, set the display sectionas shown below.When the temperature inside the enclosure is 40 to 55 ° C or less, the mounting angle should be in the range 60 to 105 degrees. GOT Display section Enclosure, etc. ...
Page 18 - Part A size: As the GOT connection cable is led out downward, the
9 (2) Mounting position When mounting the GOT, the following clearances must be left from theother device. (100mm (3.94 inch) or more) A Plate thicknesswithin 2mm to 4mm (0.08inch to 0.16inch) Other device (80mm (3.15 inch) or more) (50mm (1.97inch) or more) (50mm (1.97inch) or more) D B B C Part A ...
Page 20 - * For application of external outputs of RUN OUTPUT, please refer to
11 5.3 Wiring diagram (1) 100AC to 240V DC12/24V L L + - INPUT 100-240VAC (LG) (FG) 12/24VDC 0.1A L L RUN OUTPUT + - (2) DC24V INPUT 24VDC (LG) (FG) 12/24VDC 0.1A L L RUN OUTPUT INPUT 24VDC DC12/24V L L + - + - + - + - * For application of external outputs of RUN OUTPUT, please refer to the[A985GOT/...
Page 21 - The Precautions on the Wiring; Be sure to ground the FG terminal and LG terminal of the GOT power
12 5.4 The Precautions on the Wiring DANGER z Completely turn off the externally supplied power used in the system when installing or placing wiring. Not completely turning off all power could resultin electric shock, damage to the product. CAUTION z Be sure to ground the FG terminal and LG terminal...
Page 22 - AC; POINT
13 (1) Power supply wiring y Separate the GOT's power supply line from the lines for I/O devices and power devices as shown below.When there is much noise, connect an insulation transformer. Power supply wiring diagram 200VAC T1 Main power supply GOT power supply Insulation Transformer GOT I/O power...
Page 23 - When a dedicated grounding cannot be performed, use (2) Common; For grounding a cable, use the cable of 2 mm; Connection cable
14 (2) Grounding y For grounding, perform the following: Use a dedicated grounding wire as far as possible. (Groundingresistance of 100 or less.) y When a dedicated grounding cannot be performed, use (2) Common Grounding shown below.Also, be sure to take noise countermeasures other than grounding. (...
Page 24 - Use a grounding wire as thick and short as possible.; Connecting to the GOT Power Section
15 (b) An example of common grounding GOT CN1A CN1B CN2 CN3 FGLG Connection cable Panel grounding Grounding terminal block Use a grounding wire as thick and short as possible. FG FG LG Power equipment (Servo, etc.) * Apply single-point grounding for one system. 5.5 Connecting to the GOT Power Sectio...
Page 25 - (2) When the LG terminals and FG terminals are connected, be sure to; Connection Cable Wiring; PLC
16 POINT (1) Use the thickest possible (max. 2 mm 2 (14 AWG)) wires for the 100/200 VAC and 24 VDC power cables. Be sure to twist these wiresstarting at the connection terminals. To prevent a short-circuit shouldany screws loosen, use solderless terminals with insulation sleeves. (2) When the LG ter...
Page 26 - Precautions for back light replacement; Type; Rating plate; Conformed standard
17 5.7 Precautions for back light replacement Use the following back lights for the GOT that includes this manual. Type Model Replacement back light A975GOT-TBA(Hardware version D (JAN,1998) or later),A975GOT-TBD(Hardware version B (JAN,1998) or later) A9GT-70LTTB A975GOT A975GOT-TBA-B(Function vers...
Page 27 - Appendices; Appendix 1 Outline dimension drawing; GG; Item
18 Appendices Appendix 1 Outline dimension drawing E A D C B I H F M L K J GG Unit: mm(inch) Item A B C D E F G H I J K L M A975GOT,A970GOT 297 (11.70) 208 (8.20) 235 (9.26) 229 (9.02) 288 (11.35) 199 (7.84) 10 (0.40) 46 (1.81) 40 (1.58) 6 (0.24) 34 (1.34) 31 (1.22) 15.4 (0.61) A960GOT 268 (10.56) 1...
Page 28 - Appendix 2 Depth dimension for when mounting each type of module; Installed communication module; minimum depending on the coaxial cable connected.
19 Appendix 2 Depth dimension for when mounting each type of module (1) A97*GOT Installed communication module A [mm] (inch) B [mm] (inch) A9GT-QBUSS, A9GT-BUSS 40 (1.57) 85 (3.35) A9GT-QBUS2S, A9GT-BUS2S 62 (2.44) 85 (3.35) A9GT-BUSSU, A9GT-BUS2SU 74 (2.91) 15 (0.59) A9GT-RS2(T) 40 (1.57) *1 A9GT-R...
Page 29 - MEMO