Page 2 - ENGLISH; Installation; section of this Manual.; can cause property damage, injury or death. Read the installation,; all warranty and liability.; Retain This Manual For Future Reference
2 ENGLISH Middleby Cooking Systems Group 1400 Toastmaster Drive Elgin, IL 60120 USA (847)741-3300 FAX (847)741-4406 24-Hour Service Hotline: 1-(800)-238-8444 www.middleby.com NOTICE:This Owner's Operating and Installation Manual should be given to the user. The operator of the oven should ...
Page 3 - LOCATION AND DESCRIPTION OF CONTROLS . 15
3 ENGLISH SECTION 1 - DESCRIPTION ................................................... 4 I. OVEN USES ............................................................. 4 II. OVEN COMPONENTS ............................................. 4 A. Crumb Pans ........................................................
Page 4 - III. OVEN SPECIFICATIONS
4 ENGLISH SECTION 1 - DESCRIPTION II. OVEN COMPONENTS - see Figure 1-1. A. Crumb Pans: Catch crumbs and other material that drop through the conveyor belt. One crumb pan is located underneath each end of the conveyor. B. Conveyor Drive Motor: Moves the conveyor. C. Conveyor: Moves the food product t...
Page 5 - ments and guidelines provided in this manual.
5 ENGLISH SECTION 2 - INSTALLATION WARNING Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no obstructions around or underneath the oven. Constructional changes to the area where the oven is installed shall not affect the air supply to the oven. NOTE T...
Page 6 - I. INSTALLATION KIT; B. Additional installation kit components for gas ovens
6 ENGLISH SECTION 2 - INSTALLATION Fig. 2-1 - Installation Kit I. INSTALLATION KIT A. Installation kit components (one kit required per cavity) Item Description Part Number Lower Oven w/o Top Lower Oven w/Top Upper Oven 1 Legs, adjustable 22450-0028 4 4 - - 2a Conveyor End Stop - PS360/360S Single...
Page 7 - Return air from the mechanically driven system must not; C. Other ventilation concerns; Gas oven installations REQUIRE a mechanically driven; II. VENTILATION SYSTEM; IMPORTANT; Where national or local codes require the; MOUNTING SUCH EQUIPMENT ON
7 ENGLISH 458mm 305mm 76mm 51mm minimum B. Recommendations NOTE THAT THE HOOD DIMENSIONS SHOWN IN FIGURE 2 ARE RECOMMENDATIONS ONLY. LOCAL, NATIONAL, AND INTERNATIONAL CODES MUST BE FOLLOWED WHEN INSTALLING THE VENTILATION SYSTEM. ANY APPLICABLE L O C A L A N D N A T I O N A L C O D E S S U P E R S ...
Page 8 - IV. THERMOCOUPLE INSTALLATION; Figure 2-4 - Thermocouple Installation Locations
8 ENGLISH SECTION 2 - INSTALLATION IV. THERMOCOUPLE INSTALLATION 1. Install one thermocouple sensing bulb into each of the two holes in the rear panel of the oven, as shown in Figure 2-4. Fasten each thermocouple in place using one of the #10- 32 x 3/8" screws supplied in the Installation Kit. 2...
Page 9 - V. CONVEYOR INSTALLATION; NOTE
9 ENGLISH SECTION 2 - INSTALLATION V. CONVEYOR INSTALLATION NOTE Split belt conveyors can only be installed from the end of the oven with the drive motor.Single-belt conveyor assemblies may be inserted into either end of the oven. If it is to be installed from the end of the oven without the drive m...
Page 10 - Figure 2-11 - Conveyor and Master Link Orientation
10 ENGLISH VI. FINAL ASSEMBLY 1. Assemble the end plugs and motor housing onto the oven.2. Slide the conveyor extensions over the ends of the conveyor frame. Be sure that the extension with the drive sprocket opening is placed on the drive end. 3. Refer to Figure 2-12 for the correct location of eac...
Page 11 - CAUTION; WARNING
11 ENGLISH VIII. GAS SUPPLY CAUTION DURING PRESSURE TESTING NOTE ONE OF THE FOLLOW- ING:1. The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of 3.45 kPa.2. The oven must be isolated f...
Page 13 - C. Preparation for Use with Various Gases; After completing these procedures, perform a gas
13 ENGLISH C. Preparation for Use with Various Gases Before proceeding to set up the oven for a specific gas, check that the main gas supply valve and the circuit breaker/fused disconnect are in the OFF ("O") position.The main and pilot orifices must match the sizes shown in the Gas Orifices...
Page 15 - I. LOCATION AND DESCRIPTION OF CONTROLS; Conveyor Speed Controller:
15 ENGLISH SECTION 3 - OPERATION I. LOCATION AND DESCRIPTION OF CONTROLS Fig. 3-1 - Control Panel "BLOWER" Switch: Turns the blowers and cooling fans on and off. The HEAT Switch has no effect unless the BLOWER Switch is in the ON position. A. "HEAT" Switch: Allows the burner or hea...
Page 16 - A. DAILY STARTUP PROCEDURE; or; On gas ovens, the burner will not operate and gas will not; If the burner does not light within 15 minutes, the; B. DAILY SHUTDOWN PROCEDURE
16 ENGLISH A. DAILY STARTUP PROCEDURE 3. Turn the "CONVEYOR" ( ) switch to the ON ("I") position. 4. If necessary, adjust the conveyor speed setting by pressing the or pushbuttons on the con- veyor speed controller to change the displayed bake time.Some ovens may be e q u i p p e d...
Page 17 - III. QUICK REFERENCE: DIGITAL TEMPERATURE CONTROLLER
17 ENGLISH SECTION 3 - OPERATION III. QUICK REFERENCE: DIGITAL TEMPERATURE CONTROLLER Display Shows the Set Point or the Actual Tempera- ture in degrees Fahr- enheit (F) or Celsius (C). "SP LOCK" Light Lights when the set point is locked out from changes. This setting can only be changed by ...
Page 18 - SYMPTOM
18 ENGLISH IV. QUICK REFERENCE: TROUBLESHOOTING SYMPTOM PROBLEM SOLUTION IF THESE STEPS FAIL TO RESOLVE THE PROBLEM, CONTACT YOUR LOCAL MIDDLEBY MARSHALL AUTHORIZED SERVICE AGENT. A SERVICE AGENCY DIRECTORY IS SUPPLIED WITH YOUR OVEN. SECTION 3 - OPERATION Check that the set temperature and bake t...
Page 19 - SECTION 4 - MAINTENANCE; If a cooling fan is not operating correctly, it must be replaced
19 ENGLISH WARNING Before ANY cleaning or servicing of the oven, perform the following procedure:1. Switch off the oven and allow it to cool. Do NOT service the oven while it is warm. 2. Turn off the electric supply circuit breaker(s) and disconnect the electric supply to the oven. 3. If it is neces...
Page 21 - Split Belt Disassembly and Cleaning; DO NOT lubricate the shafts using WD40 or a similar; Figure 4-9 - Conveyor and Master Link Orientation
21 ENGLISH SECTION 4 - MAINTENANCE III. MAINTENANCE - EVERY 3 MONTHS A. Check that the oven is cool and the power is disconnected, as described in the warning at the beginning of this Section. B. Vacuum both of the blower motors, and their surrounding compartments, using a shop vacuum. C. Tighten al...
Page 23 - IMPOR; Wiring
23 ENGLISH FOR USE IN SPLIT BELT APPLICATIONS ONLY CONVEYOR SPEED CONTROLLER CONVEYOR DRIVE MOTOR PICKUP Black BLOWER SWITCH COOLDOWN RELAY CONVEYOR SWITCH COOLING FAN COOLING FAN COIL HIGH LIMIT CONTROL MODULE TEMPERATURE CONTROLLER PRESSURE SWITCH RESET SWITCH BLOWER MOTOR BLOWER MOTOR CENTRIFUGAL...
Page 24 - iring
24 ENGLISH page 1 DANSK side 25 SECTION 5 - ELECTRICAL W IRING DIAGRAMS Fig. 5-2 Wiring Diagram, PS360-U/-L or PS360WB-U/-L Gas Oven, 220-230V, 50 Hz, 1 Ph FOR USE IN SPLIT BELT APPLICATIONS ONLY CONVEYOR SPEED CONTROLLER CONVEYOR SPEED CONTROLLER CONVEYOR DRIVE MOTOR CONVEYOR DRIVE MOTOR PICKUP PIC...