Page 3 - Introduction; Environmental protection; Substances
34008030EN/AA - Page 3 Introduction Environmental protection MGE UPS SYSTEMS has implemented an environmental-protection policy.Products are developed according to an eco-design approach. Substances This product does not contain CFCs, HCFCs or asbestos. Packing To improve waste treatment and facilit...
Page 4 - Pictograms
34008030EN/AA - Page 4 Introduction Pictograms Important instructions that must always be followed. Information, advice, help. Visual indication. Action. Audio signal. In the illustrations on the following pages, the symbols below are used: LED off LED on
Page 5 - Contents; Presentation
34008030EN/AA - Page 5 Contents 1. Presentation 1.1 Standard positions ...................................................................................................................... 7 Tower position ................................................................................................
Page 6 - Troubleshooting
34008030EN/AA - Page 6 Contents 5. Troubleshooting 5.1 Troubleshooting LEDS (21) and (22) ......................................................................................... 28 5.2 Troubleshooting not requiring MGE UPS SYSTEMS after-sales support ............................. 28 5.3 Troublesho...
Page 7 - Standard positions; Tower position
34008030EN/AA - Page 7 1. Presentation 1.1 Standard positions Tower position Rack position Dimensions (H x W x D) in mm / Inches Pulsar MX 4000 RT 444.5 x 131 x 700 / 17.5 x 5.16 x 27.56 Pulsar MX 5000 RT 444.5 x 131 x 700 / 17.5 x 5.16 x 27.56 Pulsar MX EXB RT 444.5 x 131 x 650 / 17.5 x 5.16 x 25.6...
Page 8 - Pulsar MX EXB RT (optional battery module)
34008030EN/AA - Page 8 1. Presentation 1.2 Rear panels Pulsar MX 4000 RT / 5000 RT Pulsar MX EXB RT (optional battery module) (1) Two groups of 2 programmable (10A) outlets for connection of equipment (2) Groups of 4 (10A) outlets for connection of equipment (3) Groups of 2 (16A) outlets for connect...
Page 9 - Display and control panel; Rack mounting kit; ESC
34008030EN/AA - Page 9 1. Presentation 1.3 Display and control panel 1.4 Options Rack mounting kit (20) Load protected LED (21) Downgraded operation LED (22) Load not protected LED (23) Alphanumeric display (24) Escape (cancel) button (25) (26) Function buttons (scroll down / scroll up) (27) Enter (...
Page 10 - ModularEasy
34008030EN/AA - Page 10 1. Presentation ModularEasy Pulsar MX ModularEasy enables parallel operation when combining two Pulsar MX UPSs. Consequently you can enhance the availbility level of your equipment (N+1 redundancy). You can also double your secured power capacity according to your needs (migr...
Page 11 - Pulsar MX RT; Battery extensions for Pulsar MX RT; Battery Integration System
34008030EN/AA - Page 11 1. Presentation Battery extensions for UPS backup times up to 80 minutes (at full load) Pulsar MX RT offers a standard backup time of 5/7 minutes at full load. To increase backup time, it is possible to connect Pulsar MX EXB RT modules to the UPSs. Battery extensions for Puls...
Page 12 - Unpacking and contents check; NetPack; ON
34008030EN/AA - Page 12 2. Installation 2.1 Unpacking and contents check 2.2 Internal battery connection (Battery start-up) (40) Pulsar MX 4000 or 5000 UPS. (41) Two sets of tower stands. (42) RS232 communications cable (43) Product documentation. (44) 4 cable lockers. (45) Telescopic rails for rack...
Page 13 - Installation in tower position
34008030EN/AA - Page 13 2. Installation 2.3 Installation in tower position Follow steps 1 to 3 to adjust the tower stands for the upright position. Always keep 150 mm free space behind the UPS rear panel.The distance between the tower stands should be 450 mm. 1 1 2 2 3 3 ESC 3 3 450 mm 150 mm
Page 14 - Installation in rack position; Adjustment of the orientation of the logo and control panel
34008030EN/AA - Page 14 2. Installation 2.4 Installation in rack position Adjustment of the orientation of the logo and control panel UPS module rack mounting (optional rails required) Pulsar MX RT is very heavy. To ease its rack integration, we strongly recommend to remove the battery tray as shown...
Page 15 - UPS or battery module rack mounting (optional rails required); Follow steps 1 to 4 for rack mounting the UPS onto the rails.; Rear bracket system
34008030EN/AA - Page 15 2. Installation UPS or battery module rack mounting (optional rails required) It is not allowed to install the UPS or battery module in a hermetically closed environment without any exchange of air. Follow steps 1 to 4 for rack mounting the UPS onto the rails. The rails and t...
Page 16 - Communication ports; Pulsar MX; Connection to the RS 232 communication port; UPS
34008030EN/AA - Page 16 2. Installation 2.5 Communication ports Pulsar MX RT provides 3 communication methods that can be used simultaneously: ◗ 2 COM ports provide RS232 or USB communications using MGE UPS SYSTEMS SHUT protocol. Compatible with most power management software applications available ...
Page 17 - Remote power off contact normally open
34008030EN/AA - Page 17 2. Installation Remote Power Off communication port (16) (see page 8) Installation of communication cards (optional, standard with the NetPack version) Installation of a Remote Power Off function must be carried out in compliance with applicable regulations.In order to fully ...
Page 18 - Required protective devices and cable cross-sections; Recommended upstream protection; UPS power rating
34008030EN/AA - Page 18 2. Installation 2.6 Required protective devices and cable cross-sections Recommended upstream protection Recommended downstream protection Required cable cross-sections ◗ Terminal-block cable capacity: 6 mm 2 , solid or stranded wire (maximum 8 mm 2 or AWG 8). ◗ Capacity for ...
Page 19 - Connection of input/output power cables on UPS terminals
34008030EN/AA - Page 19 2. Installation 2.7 Connection of input/output power cables on UPS terminals ◗ This type of connection must be carried out by qualified electrical personnel. ◗ Before carrying out any connection, check that the battery circuit breaker (19) (see page 8) and that the upstream p...
Page 20 - Connection of IEC cables to output receptacles
34008030EN/AA - Page 20 2. Installation 2.8 Connection of IEC cables to output receptacles 1 - Connect the equipments to the UPS using the cables (49) . It is preferable to connect the priority equipments to the four outlets (2) and the non priority equipments to the four outlets (1) that can be pro...
Page 21 - UPS personalisation; The equipments are protected by the UPS.
34008030EN/AA - Page 21 3. Operation 3.1 Initial start-up UPS personalisation 3.2 Final start-up sequence It is essential to contact our Customer Service to ensure that your system is commissionned in complete safety and to benefit from the manufacturer’s guarantee. 1 - Check that the battery switch...
Page 23 - Operation on battery power; Transfer to battery power; Return on Normal AC source; The remaining battery power is low.
34008030EN/AA - Page 23 3. Operation 3.4 Operation on battery power When the Normal AC source is not available, the load continues to be protected by the UPS.Power is supplied by the battery. Transfer to battery power Low battery warning End of backup time 3.5 Return on Normal AC source After an out...
Page 25 - Access to measurements and personalisation data; Display organisation; Maintenance
34008030EN/AA - Page 25 4. Access to measurements and personalisation data 4.1 Display organisation 4.2 Access to measurements 4.3 Access to UPS set-up and maintenance using the control panel (23) Press the scroll button (24) (see section 1.3, page 9) to access measurements for voltage, current, fre...
Page 26 - Local settings
34008030EN/AA - Page 26 4. Access to measurements and personalisation data 4.4 UPS set-up Local settings Output settings ON/OFF settings Function Factory setting Options Language English French, German, Italian, Portuguese, Spanish Date / Time Format International (DD-MM-YYYY/HH :MM) US (MM-DD-YYYY/...
Page 27 - Battery settings; Personalisation using external software
34008030EN/AA - Page 27 4. Access to measurements and personalisation data Battery settings 4.5 Maintenance 4.6 Personalisation using external software Function Factory setting Options Comments Auto Battery Test Everyweek No test / everyday / everyweek /everymonth Low Batt Warning 20% 0 to 100% 1% i...
Page 30 - LCM warning details
34008030EN/AA - Page 30 6. Life Cycle Monitoring (LCM) 6.1 Description This function, embedded in the UPS, displays messages, on screen and communication channels, at every important stage of the UPS’s life, allowing you to: Get free offers Secure your installation power continuity Anticipate mainte...
Page 31 - Reset or disable LCM
34008030EN/AA - Page 31 6. Life Cycle Monitoring (LCM) Reset or disable LCM In case of any LCM messages displayed: ◗ For temporary reset: press the escape button (24) more than 3 seconds, into Status and Alarm screen , to cancel temporary the alarm status.The alert will be repeated twice each 30 day...
Page 32 - Hot swapping the battery sub-module; precautions. Keep unauthorized personel away from batteries.
34008030EN/AA - Page 32 7. Maintenance 7.1 Hot swapping the power sub-module Disconnecting the power sub-module : Reconnecting the power sub-module : 7.2 Hot swapping the battery sub-module Disconnecting the battery sub-module : This operation must be carried out by qualified electrical personnel on...
Page 33 - Maintenance on a UPS equipped with the ModularEasy MX module
34008030EN/AA - Page 33 7. Maintenance Reconnecting the battery sub-module : 7.3 Maintenance on a UPS equipped with the ModularEasy MX module Carry out the above instructions in reverse order. ◗ To ensure safety and high performance, use only batteries supplied by MGE UPS SYSTEMS. Before any action ...
Page 35 - Technical specifications
34008030EN/AA - Page 35 8. Appendices 8.1 Technical specifications (1) If the output voltage is 200V - 250V, the output power is 4500VA / 4000W.(2) With one EXB module or more, the standard output power is 5000VA / 4000W. (3) Values for 70% / 100% of UPS output.(4) Programmable: 200V / 208V / 220V /...