Page 3 - draft control must be
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. T esTing i nformaTion This manual describes the installation and operation of the Striker™ S160 non-catalytic wood heaters. These heaters meet the U.S. Environmental Protection Agency’s emissions limits for wood heaters sold on or after July 1, 19...
Page 6 - Floor Protection; All mobile home installations require an outside air kit (part #; Components Required For Installation
c learances To c omBusTiBles WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUCTION IS NOT LESS THAN SHOWN. Floor Protection USA - The floor in front and under the heater must be pro- tected with a minimum of 3/8” thick noncombustible material. Th...
Page 7 - G G; Installation; Dimensions to Stove Body * Mobile Home - USA only
Diagram B: Side View-Alcove Installation Diagram A: Top View-Parallel Installation K B A E C D *L K Floor Protector G G F F 72" Min. H M J J H † E † E L 48” Maximum Depth Diagram C: Top View-Corner Installation N P i nsTallaTion PIPE INSTALLATION A B (1) C D (1) E† F (1,) G () ” Single Wall Resi...
Page 8 - Line up the hole in the clip with the hole in
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Heatshield Mounting Holes Air Channel Front Figure 2 Figure 1 o uTsiDe a ir k iT i nsTallaTion To install the “Outside Air Kit,” position the clip so that the nut is directly above the hole punched in the back of the heatshield (See Figure 3). I...
Page 9 - Tove
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 11. For residential installations, install the first section of stove pipe with the crimped end going down inside the flue collar on the heater. Continue with your stove pipe, installing each section-crimped end down. Make the final connection t...
Page 10 - Residential and Mobile Homes
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 7. Make four 1-1/2” cuts in one end of the corrugated tube and fold the flaps back. Cut a 4’ hole through the floor protection and the floor, and insert the cor- rugated tube into the hole. Cover it with the supplied screen and fasten it to the...
Page 11 - Be sure the insulating blanket is
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. P osT i nsTallaTion c hecks 1. Check that all chimney pipe joints are securely fas- tened. 2. Check that the heater is securely fastened to the floor (if applicable). 3. Make sure the intake vent has clear access to outside air (if applicable)....
Page 13 - to improve hot air distribution throughout the room.; WARNING: In the event that you remove the blower; PeraTing; DO NOT
1 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. o PTional B loWer i nsTallaTion A blower, part# 71000, can be installed on the stove to improve hot air distribution throughout the room. To install the blower: 1. Remove all the contents from the blower box. Included with the blower should be a...
Page 14 - Be sure to clean the Nickel or Gold Plated door with
1 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. s TarTing anD m ainTaining a f ire Be sure to clean the Nickel or Gold Plated door with Windex brand cleaner and a very soft cloth to remove any fingerprints and residues prior to the first fire. 1. NEVER USE FLAMMABLE LIQUIDS TO START OR REKIND...
Page 17 - ainTenance
1 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Experiment with different loading configurations to achieve longer burns . Try loading the wood from side to side and nesting it in the ashes to prevent airflow under and around the wood. Fresh wood should be loaded to the back of the firebox or...
Page 18 - correct size chimney flue.; SMOKES WHEN; ) The draft control must be closed further.; POOR HEAT
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. T rouBleshooTing P roBlem s oluTion POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stoves’ draft depend solely on the natural draft of the ...
Page 19 - DO
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. D o ’ s anD D on ’ Ts DO NOT: Install or operate this stove before reading this manual. DO NOT: Close the draft beyond the point at which the flames are completely extinguished. DO NOT: Open the stove door without fully opening the draft first....