Page 2 - 60 DVS Series Direct Vent Fireplaces; Table of Contents
2 360 DVS Series Direct Vent Fireplaces 10006326 Installation and Operating Instructions ........................................................................................................3 Important Curing/Burning Instructions ......................................................................
Page 3 - 60DVS Series Direct Vent Fireplaces; Installation & Operating Instructions; This appliance may be installed in an aftermarket, per-; Proposition 65 Warning:; CERTIFIED TO; Vented Gas Fireplace Heaters
3 360DVS Series Direct Vent Fireplaces 10006326 This gas appliance should be installed by a qualified installer, preferably NFI or WETT (Canada) certified, in accordance with local building codes and current CSA-B149.1 Installation Codes for Gas Burning Appliances and Equipment. If the unit is being i...
Page 4 - “GAS VENT DIRECTLY BELOW, KEEP; MANUFACTURER REQUIREMENTS; Gas Equipment Venting System NOT Provided
4 360 DVS Series Direct Vent Fireplaces 10006326 Requirements for the Commonwealth of Massachusetts All gas fitting and installation of this heater shall only be done by a licensed gas fitter or licensed plumber.For all side wall horizontally vented gas fueled equipment installed in every dwelling, bu...
Page 5 - Fireplace Dimensions - 360DVS2; Fireplace specifications—360DVS2; Rear Vent Configuration
5 360DVS Series Direct Vent Fireplaces 10006326 J J K K H D A E B I E A F C H 6326 360DVS2 top vent specs Electrical Access Gas Line Access Electrical Access Gas Line Access K J J K J J G J J K K H D A E B E A F C K H 6326 360DVS2 rear vent specs G I Electrical Access Gas Line Access Electrical Acce...
Page 7 - Framing Dimensions - 360DVS2; Fireplace framing dimensions—360DVS2
7 360DVS Series Direct Vent Fireplaces 10006326 ROH ROD ROW CFM121 360DVS2 REAR VENT CONFIGURATION 8/10/00 Framing Dimensions - 360DVS2 CFM122 360DVS2 - TOP VENT CONFIGURATION 8/10/00 ROD ROH ROW Rear VentConfiguration Top VentConfiguration CFM121 CFM122 Framing Dimensions Ref. Rear Vent Configuration ...
Page 8 - Rear Vent Confiration; Framing Dimensions
8 360 DVS Series Direct Vent Fireplaces 10006326 CFM123_360DVS3_dims_RV2 REAR VENT CONFIGURATION 8/10/00 rev. 8-23-02 rjs ROD ROW ROD ROH ROH ROH ROD 360DVSL 360DVS/3/L/R 360DVS3 360DVSR CFM124_360DVS3_TV2 TOP VENT CONFIGURATION 8/10/00 rev. 8-23-02 rjs ROD ROD ROH ROW ROH ROH ROD 360DVSL 360DVS/3/L...
Page 9 - Mantels; Combustible mantel minimum installation.; Combustible mantel leg minimum installation.; Locating Your Fireplace; locate fireplace
9 360DVS Series Direct Vent Fireplaces 10006326 Top of unit to ceiling ................................. 36” (914 mm)Front of unit to combustibles ................... 36” (914 mm)Appliance Top .........................................0” (0 mm) to standoff Bottom ........................................
Page 10 - Cold climate installation recommendation:; Hearth; Frame in the fireplace with a header across the top.; ing to constructed frame, not the appliance.; Gas Specifications; Natural; Inlet Minimum; Gas Line Installation
10 360 DVS Series Direct Vent Fireplaces 10006326 A hearth is not mandatory; however, for aesthetic purposes, we recommend installing a noncombustible hearth that projects out 12” (305mm) or more from the front of the fireplace. Cold climate installation recommendation: When installing this unit agai...
Page 11 - Gas shutoff valve and flex connector.; EB-1 Electrical Junction Box Connection; Canadian Electrical Code.; Remote ON/OFF Switch Installation; Remote switch wiring diagram for R models.; Alternate Switch Location
11 360DVS Series Direct Vent Fireplaces 10006326 FP297A INSTA VENT FREE UVHB26 GAS SUPPLY 7/1/98 1/2” Gas Supply 1/2” NPT X 1/2” Flare Shut-Off Valve 3/8” Flex Line (From Valve) FP297a Fig. 5 Gas shutoff valve and flex connector. When using copper or flex connector, use only ap- proved fittings. Always...
Page 12 - Alternate switch location.; Optional Top Vent Application; Remove screws from outer collar adapter.; Remove flue cover and pipe.
12 360 DVS Series Direct Vent Fireplaces 10006326 FP1430 Fig. 8 Alternate switch location. Optional Top Vent Application This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con-figuration, the appliance can be converted by following the steps b...
Page 13 - Electronic Gas Control Valve; Thread the wiring through the holes on the side; Honeywell ignition module.; There must not be any obstruction; General Venting; Location of Vent Termination
13 360DVS Series Direct Vent Fireplaces 10006326 Electronic Gas Control Valve This appliance may be fitted with a Honeywell ignition module. Installation of the remote ON/OFF starter switch on electronic ignition units (Fig. 12): 1. Thread the wiring through the holes on the side panels of the applia...
Page 14 - General Venting Information - Termination Location; Canadian Installations
14 360 DVS Series Direct Vent Fireplaces 10006326 V V V V V V V X X X D E B B B C B M B A J K F L VENT TERMINATION AIR SUPPLY INLET AREA WHERE TERMINAL IS NOT PERMITTED H I ����� ������ Operable Operable Fixed Closed V B CFM145aDV Termin Location5/01/01 Rev. 12/05/01 sta INSIDE CORNER DETAIL V A G N...
Page 15 - Termination clearances.; General Information Assembling Vent Pipes; Canadian Installations:; Venting system must be installed in accordance with the; Twist Lock Pipes; For ease of assembly, use a lubricant (Vaseline; Twist lock pipe joints.; Termination Clearances; of Caps
15 360DVS Series Direct Vent Fireplaces 10006326 Fig. 14 Termination clearances. General Information Assembling Vent Pipes Canadian Installations: Venting system must be installed in accordance with the current CSA-B149.1 installation code. USA Installations: The venting system must conform with loc...
Page 16 - How to Use the Vent Graph; ertical dimension from fl; Sidewall vent graph.; Rear Wall Application; Rear vent application.; Rear Wall Installation; Noncombustible walls:
16 360 DVS Series Direct Vent Fireplaces 10006326 How to Use the Vent Graph The vent chart should be read in conjunction with the following vent installation instructions to determine the relationship of the vertical and horizontal dimensions of the vent system.1. Determine the height of the center ...
Page 17 - Vent Opening for Combustible Wall; Locate vent opening on rear wall.; Vertical Sidewall Application; When installing the appliance as a rear vent; Side View; Adjustable zero clearance sleeve.
17 360DVS Series Direct Vent Fireplaces 10006326 VO584-100 Vent Opening 2/99 djt Vent Opening for Combustible Wall 9 ³⁄₈ ” (240mm) 10 ³⁄₈ ” (265mm) Framing Detail Vent Opening for Noncombustible Wall 7 ¹⁄₂ ” (190mm) VO584-100 Fig. 18 Locate vent opening on rear wall. STEP 3 Measure the horizontal le...
Page 18 - Horizontal run reduction.; Vertical Side Wall Installation
18 360 DVS Series Direct Vent Fireplaces 10006326 Horizontal plane means no vertical rise exists on this portion of the vent assembly. • The maximum number of 90˚ elbows per side wall installation is three (3). • If a 90˚ elbow is fitted directly on top of the fireplace flange, the maximum horizontal v...
Page 20 - Below Grade Installation; pipe coming through the wall.; Below grade installation.; Snorkel installation / recessed foundation.
20 360 DVS Series Direct Vent Fireplaces 10006326 2” (51 mm). Secure termination to the wall with screws provided, and caulk around the wall plate to weather-proof.One alternative to screwing the termination directly to the wallis the use of expanding plugs or an approved exterior construction adhes...
Page 21 - This Gas Fireplace has been approved for:; Support straps for horizontal runs.; Maximum horizontal length:; Maximum elbow usage.
21 360DVS Series Direct Vent Fireplaces 10006326 Vertical Through-the-Roof Application This Gas Fireplace has been approved for: • Vertical installations up to 40’ (12 m) in height. Up to a 10’ (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90° elbows. (Fig....
Page 22 - port Application; Firestop and attic insulation shield.
22 360 DVS Series Direct Vent Fireplaces 10006326 Vertical Through-the-Roof Installation 1. Locate your fireplace.2. Plumb to center of the (4”) flue collar from ceiling above and mark position. 3. Cut an opening equal to 9 ³⁄₈ ” x 9 ³⁄₈ ” (240 x 240mm). 4. Proceed to plumb for additional openings thr...
Page 23 - vent components; Venting Components; Vent Components; Vent components; Twist Lock Venting Components
23 360DVS Series Direct Vent Fireplaces 10006326 584B Vent components Starter Kit 2/25/99 djt 584G Venting Components Firestop spacer 2/25/99 djt 584H Venting components attic insulation shield 2/25/99 djt 584I vent components offset support 2/25/99 djt 584F Venting Components Pipe sections 2/25/99 ...
Page 24 - Operating Instructions; Glass Information; • The top side and top end; Louvre Removal; Louvre removal; Window Frame Assembly Removal; remove glass frame
24 360 DVS Series Direct Vent Fireplaces 10006326 Operating Instructions Only glass approved by CFM Corporation should be used on this fireplace. Glass Information • The top side and top end louvres are removed by simply lifting the louvre assembly and pulling the assembly away from the fireplace. (Fi...
Page 25 - Glass Cleaning; Ceramic panel installation.; Log Installation; log
25 360DVS Series Direct Vent Fireplaces 10006326 Glass Cleaning It is necessary to periodically clean glass. During start-up, condensation, which is normal, forms on the inside of the glass. This condensation causes lint, dust and other airborne particles to cling to glass surface.Also initial paint...
Page 26 - logs; Side of Fireplace; Side of Fireplace; 60DVS log placement.; Lava Rock and Ember Material Placement; Ember Material; Flame & Temperature Adjustment
26 360 DVS Series Direct Vent Fireplaces 10006326 LG320 360DVS logs B120 B121 B122 B123 B124 B126 B125 LG320 Fig. 40 360DVS log placement. Side of Fireplace V enting Side V enting Side LG321 360DVS logs opposite side B120 B121 B122 B123 B126 B125 Side of Fireplace LG321 Fig. 41 360DVS log placement....
Page 27 - Flame adjustment knob for SIT valve.; Flame Characteristics; Correct pilot flame appearance.
27 360DVS Series Direct Vent Fireplaces 10006326 L O HI FP390 FLAME ADJUSTMENT KNOB 11/21/96 Turn counterclockwise to increase flame height Turn clockwise to decrease flame height Fig. 43 Flame adjustment knob for SIT valve. Flame Characteristics It is important to periodically perform a visual chec...
Page 28 - To Turn OFF Gas to Heater; Euro SIT
28 360 DVS Series Direct Vent Fireplaces 10006326 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace. 3. For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level. 4. Ope...
Page 29 - Lighting and Operating Instructions; Shutoff valve
29 360DVS Series Direct Vent Fireplaces 10006326 Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) A. This fireplace is equipped with an ignition device which automatically lights the pilot. DO NOT try to light the pilot by hand. B. BEFORE OPERATING , smell ...
Page 30 - SIT NOVA 820 MILLIVOLT VALVE; Troubleshooting the Gas Control System; SYMPTOM
30 360 DVS Series Direct Vent Fireplaces 10006326 NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. SIT NOVA 820 MILLIVOLT VALVE Troubleshooting the Gas Control System WARNING: REMOVE GLASS FRONT BEFORE DOING ANY GAS CONTROL SERVICE WORK. SYM...
Page 31 - SIT 822 Valve with a Honeywell Electronic Igniter; START
31 360DVS Series Direct Vent Fireplaces 10006326 SIT 822 Valve with a Honeywell Electronic Igniter NOTE: Remove glass before servicing. START TURN GAS SUPPLY OFF. TURN ON/OFF SWITCH TO CALL FOR HEAT.POWER TO MODULE? (24V NORMAL) SPARK ACROSS IGNITOR SENSOR GAP? YES YES YES TURN GAS ON. PILOT BURNER ...
Page 32 - Troubleshooting – Honeywell VS8421
32 360 DVS Series Direct Vent Fireplaces 10006326 Troubleshooting – Honeywell VS8421 START CHECK Gas Supply On Pilot Lights With Piezo Ignitor • Lockout Has Engaged. Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo 1/8" Gap To Pilot Hood Needed. • All Wiring Connect...
Page 33 - Fuel Conversion Instructions; air shutter; Air shutter adjustment.; Remove mounting screws, pressure regulator tower
33 360DVS Series Direct Vent Fireplaces 10006326 Fuel Conversion Instructions To convert this appliance from gas type to another, fol- low these instructions. Before proceeding, turn control knob to “OFF” and turn gas supply OFF . Turn OFF any electricity that may be going to the appliance. CAUTION:...
Page 34 - Honeywell valve; Honeywell conversion screw replacement.; Honeywell Gas Control Valve
34 360 DVS Series Direct Vent Fireplaces 10006326 D E F FC108 SIT regulator conversion 10/03 OFF PILOT O N FC108 Fig. 49 Replace regulator. 10. Reassemble fireplace in the reverse order, except for the window frame assembly. Leave this off until after unit has been checked for leaks and the gas suppl...
Page 35 - Burner and Burner Compartment; Cleaning the; Maintenance; Cleaning Electronic Ignition System
35 360DVS Series Direct Vent Fireplaces 10006326 Burner and Burner Compartment It is important to keep the burner and the burner com-partment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the instr...
Page 37 - * Ceramic Burner Tile
37 360DVS Series Direct Vent Fireplaces 10006326 360DVS Series (Items marked ‘*’ are not shown in the parts illustration) Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR 1. Log Set (complete) 10006350 10006350 10006350 10006350 1a. Log - Rear (B120) 10006315 10006315 10006315 10006315 1b. Log - Fro...
Page 39 - Optional Accessories; Fan Kits; Install the thermal sensor under the bottom of the; Fan kit
39 360DVS Series Direct Vent Fireplaces 10006326 Optional Accessories Fan Kits FK24 Fan Assembly This auxiliary fan system increases the efficiency of the circulation of the heated air.The FK24 fan kit allows variable speed control of the circulation fan and also incorporates a heat sensor in the cir...
Page 40 - Wiring Instructions; Method ‘A’ fan wiring diagram.; Remote Controls; Installation; Decorative trim frame installation.
40 360 DVS Series Direct Vent Fireplaces 10006326 Wiring Instructions The fireplace, when installed, must be elec-trically connected and grounded in accor-dance with local codes, or in the absence of local codes, with the current CSA C22.1 Canadian Electric Code. For USA installa-tions, follow local ...
Page 43 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have your warranty,; LIMITED LIFETIME WARRANTY; PRODUCT COVERED BY THIS WARRANTY
43 360DVS Series Direct Vent Fireplaces 10006326 BASIC WARRANTY CFM Corporation (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defects for a period of one year from the date of purc...
Page 44 - Efficiency Ratings; Model; CFM Corporation
Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 360DVS2RN 62.4 83 84 65 360DVS2RP 62.4 83 84 65 360DVS2EN 62.4 83 84 65 360DVS2EP 62.4 83 84 65 360DVS3RN 62.4 83 84 65 360DVS3RP 62.4 83 84 65 360DVS3EN 62.4 83 84 65 360DVS3EP 62.4 83 8...