Page 2 - Vermont Castings Radiance Vent-Free Gas Heater; Assembly Procedures; Table Of Contents
2 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Installation and Operating Instructions ....................................................................................... 3 Stove Dimensions ..................................................................................................
Page 3 - Installation & Operating Instructions; F temperature rating.
3 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Installation & Operating Instructions In order to ensure safe and effective installation, this unitmust be installed only by a qualified agency, individual, firm,corporation or company that is experienced in the installa-tion, repair and ...
Page 4 - Radiance Vent Free Gas Heater Dimensions
4 Vermont Castings Radiance Vent-Free Gas Heater 20004555 31" (787mm) 29 ³⁄₄ " (756mm) R A D I A N C E 18 ³⁄₈ " (465mm) 11" (279mm) 28 ¹⁄₄ " (717mm) 6 ¹⁄₂ " (165mm) Drawing Not to Scale 4555 Supply Inlet Fig. 1 Radiance Vent Free dimensions. Radiance Vent Free Gas Heater Dime...
Page 5 - Clearance Requirements; Minimum Clearances to; Mantel; Alcove Clearances
5 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Clearance Requirements Minimum Clearances to Combustible Materials Maintain clearance, (empty space), between combus-tible materials and the heater as specified below. Hearth Requirements The Radiance Unvented heater must be installed onrigid...
Page 6 - Firebox weight / shipping; Unvented Heaters; Input; RUVSODRN; Inlet Minimum; Gas Inlet and Manifold Pressures; Natural
6 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Firebox weight / shipping 175 lbs. The installation of your Vermont Castings stove mustconform with local codes, or in the absence of localcodes, with the National Fuel Gas Code ANSIZ223.1 - latest edition. (EXCEPTION: Do not deratethis appli...
Page 7 - You must determine that these fresh; Unusually Tight Construction is
7 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Vent Free Features The Radiance RUVSOD, Model Nos. 3370 thru 3379,is an unvented gas heating appliance tested and listedto the ANSI standard Z21.11.2-2000. This appliance isspecifically configured to burn either Natural Gas orPropane fuel, as...
Page 8 - W A R N I N G; criteria and no; Fig. 4 Vent options to provide additional air.
8 Vermont Castings Radiance Vent-Free Gas Heater 20004555 W A R N I N G This heater shall not be installed in a confinedspace unless provisions are made for adequatecombustion and ventilation air. W A R N I N G If the area in which the heater may be operated issmaller than that defined as an unconfi...
Page 9 - Tools Required
9 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Read these instructions thoroughly before startingthe assembly. Follow procedures in the ordergiven. Inspect the stove for damage before startingthe assembly. Do not install this stove if anydamage is evident. Contact your dealer immedi-ately...
Page 10 - Install Optional Fan
10 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Install Optional Fan It is easiest to install the optional fan kit #2767/FK26,before the stove is moved to its final location or con-nected to the gas line. The fan consists of a blower assembly and a rheostatswitch that are connected by a w...
Page 11 - Fig. 10 Attach the fan assembly to the fan bracket.
11 Vermont Castings Radiance Vent-Free Gas Heater 20004555 4. Attach the fan assembly to the fan bracket providedin the log box. Use #10 sheet metal screws providedwith fan kit. Do not remove finger guard screws.(Fig.10) 5. Connect snapstat leads. Disconnect the snapstatmodule from the leads inside ...
Page 12 - Disconnect power; Install ON/OFF Switch; Run wires down back of stove, under bottom of rear; Fig. 17 Attach switch wires to valve; Fig. 16 Attach switch assembly to rear shroud.; Thermostat Wire / Gauge
12 Vermont Castings Radiance Vent-Free Gas Heater 20004555 MOTOR SNAPSTAT ON/OFF RHEOSTAT WHT WHT BLK BLK BLK GRN BLK POWER Fig. 15 #2767 / FK26 Fan Wiring Diagram Disconnect power before servicing. ST196 The optional fan kit is equipped with a three-prong (grounding) plug for your protection agains...
Page 13 - Glass & Catalyst Installation; Optional Thermostat Wiring; Fig. 19 Be sure injector orifices remain at 90
13 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Glass & Catalyst Installation CAUTION: Air shutter must be removedwhen installing glass and catalyst forproper operation. 1. Remove left and right log bracket assembly byunfastening the two screws which hold the burner inplace. Loosen th...
Page 14 - Install Log Set; Remove the logs from their packaging, and inspect; CAUTION; NEVER test with an open flame.; Fig. 22 Set glass frame in place and secure latches.
14 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Install Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NOT INSTALL DAM-AGED LOGS. 2. Install the rear left log by placing it on the sheet metal shelf at the back of the firebox. (Fig. 23) Thelog should...
Page 15 - Loosely sprinkle the lava rocks directly on top of the; Top View; Complete the Installation; Replace the screen frame by sliding the hooks over; Fig. 27 Attach the handle to the control door.
15 Vermont Castings Radiance Vent-Free Gas Heater 20004555 5. Loosely sprinkle the lava rocks directly on top of the burner just behind decorative grate. (Fig. 25) Usethe lava rock to cover brackets on the burner. Donot place lava rocks toward back of burner. The lavarock is shipped inside the bag a...
Page 16 - Operation; Your First Fire; Fig. 28 To open the front doors, turn handle counterclockwise.; LO; Flame Characteristics
16 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Operation The Radiance is shipped with the operable door frontplate. The stove may be operated with the doors eitheropen or closed. To open the front doors, insert thehandle provided into the door latch stub and turn it tothe right and up. (...
Page 17 - FOR YOUR SAFETY READ BEFORE LIGHTING; WHAT TO DO IF YOU SMELL GAS; To Turn Off Gas To Heater; Lighting And Operating Instructions; Lighting Instructions; Euro SIT
17 Vermont Castings Radiance Vent-Free Gas Heater 20004555 3. Open control access panel.4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above.2. Turn off all electrical power to the fireplace....
Page 18 - Troubleshooting
18 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Troubleshooting Follow these procedures in the order presented. W A R N I N G TURN OFF HEATER AND ALLOW TO COOLCOMPLETELY BEFORE SERVICING. CONDITION POSSIBLE CAUSE SOLUTION No spark at pilot when Ignitor isoperated. 1. Ignition Electrode is...
Page 19 - Troubleshooting cont’d.; CONDITION; Correct LP Pilot Flame.
19 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Troubleshooting cont’d. CONDITION POSSIBLE CAUSE SOLUTION Pilot lights but flame goes outwhen Control Knob is released. 1. Control Knob not fully depressed or held in long enough. 2. Gas supply line shut-off valve is not fully open. 3. Therm...
Page 20 - pletely before cleaning.; Maintenance; Fig. 35 Remove the screen or glass panel.
20 Vermont Castings Radiance Vent-Free Gas Heater 20004555 The following procedures will help ensure that yourheater continues to perform safely and efficiently. Firebox Cleaning and Inspection Cleanliness is critical to correct operation of theheater. The log set, burner, valve controls and aircirc...
Page 21 - Catalytic Combustor; Use the phillips screwdriver to remove the two sheet; Clean the Combustor Module; Clean the outer surface of the filter with the brush; Replace the Combustor Module; Slide the combustor through the front opening of the; Fig. 37 Remove the catalytic combustor module.
21 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Catalytic Combustor The combustor should be cleaned annually to ensureoptimal performance. Follow the procedure below. Remove the Combustor Module 1. Be sure the heater is COLD. 2. Remove the front plate, top grille and screen. (Fig. 36) 3. ...
Page 22 - Description; Right Rear Log RUVSOD
22 Vermont Castings Radiance Vent-Free Gas Heater 20004555 PILO T O N OFF PILOT ADJ L O HI TPTH TH TP 1a 1b 1c 2 4 6 7 13 3 23 8 16 17 18 5 10a,b 21 19 9 20 24a,b,c,d 11a 11b 15 25 27 28 29 22 14 12a,b 30 4555 Vermont Castings, Majestic Products reserves the right to make changes in design, material...
Page 23 - Classic
23 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Radiance Vent Free Gas Heater (RUVSOD) Models 3370 thru 3379 (continued) Ref. Description RUVSOD 7. Trim ON/OFF Switch 53606 8. Handle Package, Ceramic w/Screw 0004342 9. Damper Steel Handle/Screw 5004265 10a. Valve NG Honeywell - VS84212003...
Page 24 - Optional Accessories; Fan Kits
24 Vermont Castings Radiance Vent-Free Gas Heater 20004555 Optional Accessories Fan Kits FK26 Fan The FK26 fan helps distribute heated air from withinthe firebox out into the room. The fan is controlled by asnapstat that turns power on and off as the fireboxtemperature rises above and falls below a ...
Page 25 - IF WARRANTY SERVICE IS NEEDED...; ) Contact your supplier. Make sure you have; LIMITED LIFETIME WARRANTY
25 Vermont Castings Radiance Vent-Free Gas Heater 20004555 BASIC WARRANTY Vermont Castings , Majestic Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas Fireplace/Stove is free from manufacturing and material defectsfor a period of ...
Page 26 - Vermont Castings, Majestic Products
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www.majesticproducts.com • www.vermontcastings.com Vermont Castings, Majestic Products