Page 2 - CAUTION; AVIS; ATTENTION; SAFETY INSTRUCTIONS; — To reduce the risk of fire or electric; TABLE OF CONTENTS
UP4000 – 2 CAUTION AVIS RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL ATTENTION: POUR EVITER LES RISQUES DE CHOC ELECTRIQUE...
Page 3 - INTRODUCTION; KEY FEATURES
UP4000 – 3 2. INTRODUCTION KEY FEATURES • Balanced and Unbalanced Inputs • Balanced Input Priority Function • Unbalanced Line-Level Output • Convection Cooled Power AmplifierUP4061: 60 Watts RMSUP4121: 120 Watts RMSUP4161: 160 Watts RMS • 4 Ω Constant-Impedance Output • 25V, 50V, 70V, and 100V Const...
Page 4 - Constant-Impedance Output
UP4000 – 4 FRONT PANEL FEATURES LOW EQ is a shelving filter that provides 12 dB of boost and cut below 100Hz. HIGH EQ is a shelving filter that provides 12 dB of boost and cut above 10kHz. VOLUME is a master volume control used to adjust the overall volume of the signal at the POWER OUTPUTS . Use th...
Page 6 - Installation; Application Diagram
UP4000 – 6 + D.C. FUSE 115 0 50V 70V 100V POWER OUTPUTS 0 25V POWER INPUT 24V D.C. COMMANDS VOLTAGE SELECTOR POWER OUTPUTS LINE 50/60 Hz-115/230V - 4 INPUT 0 dB 20 dB ON OFF PRIORITY GND UNBALANCED IN GND H.P. FILTER BALANCED IN L.P. STAND BY SENSITIVITY GND PARALLEL OUT OVERL. 300mA. max CONCEIVED,...
Page 7 - Connections; Connecting the INPUT; INPUT Terminal Strip: Balanced Connection; Connecting the UNBALANCED IN; UNBALANCED IN; Connecting the Speakers; OUTPUT TERMINALS; INPUT Terminal Strip: Unbalanced Connection
UP4000 – 7 Connections Connecting the INPUT The Input has a balanced screw terminal connector that accepts a line-level signal. The screwterminals should be connected as shown in thefollowing figure: + – PRIORITY GND BALANCED IN COLD (–) HOT (+) SHIELD Strip the wire back about 1/2" inch, loosen...
Page 8 - Internal Settings; STANDBY MODE; Thermal Considerations; ON; UP4000 Series Input Board Jumper; AC Power Considerations; Voltage Conversion
UP4000 – 8 Internal Settings There is one setting that can be changed inside the UP4000 Series Amplifier. This setting should bemade prior to installation. CAUTION: These servicing instructions are for use by qualified personnel only. Toavoid electric shock, do not perform any servicing other than t...
Page 9 - Operation; Using the BALANCED IN; PRIORITY Function; Using the UNBALANCED IN; Direct Speaker Connection; UP4000 Series Daisy-Chaining Inputs
UP4000 – 9 4. Operation Using the BALANCED IN The BALANCED IN accepts a line-level signal. Connect the input source to the BALANCED IN barrier strip screw terminals. PRIORITY Function The BALANCED IN has priority over the UNBALANCED IN . The priority function can be activated by connecting a normall...
Page 10 - Specifications; UP4000 Series Block Diagram; Power Amplifier Section
UP4000 – 10 SENSITIVITY INPUT GND PRIORITY BALANCED IN MASTER VOLUME 100V 70V FEEDBACK LOOP 50V 25V 4 Ω 0 UNBALANCED IN PARALLEL OUT POWER AMPLIFIER AUDIO OUTPUT TRANSFORMER GND GND COMMANDS STANDBY OVERL. +18VDC SIGNAL OVERLOAD PEAK MACKIE INDUSTRIALUP4000 SERIESBLOCK DIAGRAM(#2.02.01.DF) INPUT PRI...
Page 11 - General; Service Information; In the event that your UP4000 Series amplifier; This is very; Mackie Industrial; Disclaimer; Mackie Industrial continually engages in
UP4000 – 11 General Power Consumption UP4060: 180 VA UP4120: 450 VA UP4160: 550 VA AC Line Voltage 115 VAC, 60Hz 230 VAC, 50Hz Fuse Ratings Model Line Fuse 230 VAC Line Fuse 115 VAC 24 VDC Fuse UP4060 1.25AT 2.5AT 5AT UP4120 2.5AT 5AT 10AT UP4160 3.15AT 6.3AT 16AT Dimensions Height: 3.5" (88mm) ...
Page 12 - Power Amplifier
UP4000 Series Power Amplifier www.mackieindustrial.com 16220 Wood-Red Road NE, Woodinville, WA 98072 USA TEL 888.337.7404, FAX 425.487.4337, [email protected] UK +44.1268.571.212, FAX +44.1268.570.809 [email protected] ITALY +39.0522.354.111, FAX +39.0522.926.208 [email protected] FRANCE +...