SAFETY i i IDEALARC CV-400 FOR ENGINEpowered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the eng...
SAFETY ii ii IDEALARC CV-400 ARC RAYS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks andthe rays of the arc when welding or observingopen arc welding. Headshield and filter lensshould conform to ANSI Z87. I standards. 4.b. Use suitable clothing m...
IDEALARC CV-400 FOR ELECTRICALLYpowered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working onthe equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’srecommendations. 8.c. Ground the...
SAFETY iv iv IDEALARC CV-400 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vou...
MASTER TABLE OF CONTENTS FOR ALL SECTIONS v v IDEALARC CV-400 Page Safety ...............................................................................................................................................i-i-v Installation ...................................................................
TABLE OF CONTENTS - INSTALLATION SECTION - Section A-1 Section A-1 IDEALARC CV-400 Installation ............................................................................................................................. Section A Technical Specifications ..............................................
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC INSTALLATION A-2 A-2 IDEALARC CV-400 TECHNICAL SPECIFICATIONS - IDEALARC CV-400 INPUT - THREE PHASE ONLY Standard Voltag...
Read this entire installation section before youstart installation. SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts such as output terminals orinternal wiring. • Insulate yourself from the work and ground. • Turn power switch off before connecting or discon- nectin...
GROUND CONNECTION The frame of the welder must be grounded. An earthgrounding lead must be connected to the groundingterminal, marked on the input box floor with the symbol (See Figure A.2). Refer to Technical Specifi- cations page for proper ground wire size. INPUT SUPPLY CONNECTIONS Be sure the vo...
Have a qualified electrician connect the input powerleads to the L1, L2, and L3 terminals of the input con-tactor. Follow all national and local electrical codes.Use a three-phase line. Install the reconnect paneljumper links (see Figure A.3) for the proper input volt-age. See the connection diagram...
RECONNECT PROCEDURE Multiple input voltage welders are shipped from the fac-tory connected for the highest voltage listed on themachine's rating plate. Before installing the welder, besure the reconnect panel is connected for the propervoltage. Failure to follow these instructions can cause immedi-a...
INSTALLATION A-7 A-7 IDEALARC CV-400 Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC 2 1 + - FIGURE A.5 OUTPUT TERMINAL CONNECTIONS 1. NEGATIVE (-) WELDING CABLE CONNEC...
CONNECT WIRE FEEDERS The wire feeder control cable can connect to the CV-400 at the 14-pin amphenol on the front of the machine(with the appropriate adapter cable) or the terminalstrips behind the hinged control panel cover. A strainrelief box connector is provided for cable access to theterminal st...
Section B-1 Section B-1 IDEALARC CV-400 TABLE OF CONTENTS - OPERATION SECTION - Operation ............................................................................................................................... Section B Safety Precautions ........................................................
OPERATION B-2 B-2 IDEALARC CV-400 Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC OPERATING INSTRUCTIONS Read and understand this entire section of operatinginstruction...
GENERAL DESCRIPTION The IDEALARC CV-400 is an SCR controlled three-phase input, DC output power source for welding. Ituses a single range potentiometer control. Thewelder's unique combination of transformer, threephase hybrid rectifier, capacitor bank, output choke,and solid state control system del...
WELDING CAPABILITY The CV-400 has the following duty cycle ratings. If theduty cycle is exceeded, a thermal protector will shut offthe machine output until it cools to normal operatingtemperature. The amber thermal protection indicatorlight will turn on until the machine cools. *Based on a 10 minute...
1. POWER SOURCE PILOT LIGHT: This light indi- cates that the power source input contactor is ener-gized (closed). This also means that the main powertransformer and all auxiliary control transformers areenergized. 2. ON/OFF POWER TOGGLE SWITCH: Energizes or deengergizes the input contactor. The swit...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC OPERATION B-6 B-6 IDEALARC CV-400 WELDING OPERATION LOCAL CONTROL The following procedures are for using the CV-400 inth...
OVERLOAD PROTECTION The power source is thermostatically protected withproximity thermostats against overload or insufficientcooling. One thermostat is located on the nose of thecenter bottom primary coil and a second thermostat isattached to the lead connecting the secondaries. Boththermostats are ...
NOTES B-8 B-8 IDEALARC CV-400 Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC
TABLE OF CONTENTS - ACCESSORIES - Accessories ........................................................................................................................... Section C Options/Accessories .......................................................................................................
OPTIONS/ACCESSORIES The following options/accessories are available for yourCV-400 from your local Lincoln Electric Distributor. FACTORY INSTALLED OPTIONS Diode Option - This internally installed option allowsuse of the cold start and cold electrode sensing fea-tures of the NA-3, NA-5, or NA-5R auto...
ELECTRIC SHOCK can kill. • Only qualified personnel should per- form this maintenance. • Turn the input power OFF at the dis- connect switch or fuse box beforeworking on this equipment. • Do not touch electrically hot parts. • Insulate yourself from work and ground. • Always wear dry insulating glov...
5. Extend wire feeder control cable lead #21 so it can be connected directly to the work piece. a. Make a bolted connection using AWG #14 or larg- er insulated wire. Tape the bolted connection withinsulating tape. b. An S-16586- X remote voltage sensing work lead is available for this purpose. c. Ke...
ACCESSORIES C-6 C-6 IDEALARC CV-400 Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC FIGURE C.4 LN-7 WIRE FEEDER CONNECTION TO THE IDEALARC CV-400 + - ELECTRODECABLE TOA...
Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Section D-1 Section D-1 IDEALARC CV-400 TABLE OF CONTENTS -MAINTENANCE- Maintenance ......................................................................................................................... Sectio...
SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should perform this maintenance. • Turn the input power OFF at the discon- nect switch or fuse box before workingon this equipment. • Do not touch electrically hot parts. ROUTINE AND PERIODIC MAINTENANCE To avoid receiving an ele...
MAINTENANCE D-3 D-3 IDEALARC CV-400 Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC 9 10 11 8 7 6 5 1 2 3 4 FIGURE D.1 Major Component Locations 1. BASE2. CASE FRONT3. ...
Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Section E-1 Section E-1 IDEALARC CV-400 Theory of Operation ............................................................................................................. Section E General Description ...............
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC INPUT LINE VOLTAGE, CONTACTORAND MAIN TRANSFORMER The desired three-phase input power is connected tothe CV-400 through ...
THEORY OF OPERATION E-3 E-3 IDEALARC CV-400 Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC OUTPUT CONTROL,RECTIFICATION AND FEEDBACK The three-phase AC output from the...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC THEORY OF OPERATION E-4 E-4 IDEALARC CV-400 FIGURE E.4 – CV-400 TRIGGER AND THERMAL LIGHT CIRCUIT #240 #41 CONTROL BOARD...
SCR OPERATION A silicon controlled rectifier (SCR) is a three-terminaldevice used to control rather large currents to a load.An SCR acts very much like a switch. When a gate sig-nal is applied to the SCR, it is turned ON, and there iscurrent flow from anode to cathode. In the ON state theSCR acts li...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC HOW TO USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory Trained Personn...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC ELECTRIC SHOCK can kill. Have an electrician install and servicethis equipment. Turn the machine OFFbefore working on eq...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-4 F-4 IDEALARC CV-400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beg...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-5 F-5 IDEALARC CV-400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beg...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-6 F-6 IDEALARC CV-400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beg...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-7 F-7 IDEALARC CV-400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beg...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-8 F-8 IDEALARC CV-400 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beg...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-9 F-9 IDEALARC CV-400 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beg...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-10 F-10 IDEALARC CV-400 CONTROL TRANSFORMER (T2) VOLTAGE TEST WARNING Service and repair ...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-11 F-11 IDEALARC CV-400 FIGURE F.1 – CONTROL TRANSFORMER AND LEAD LOCATIONS CONTROL TRANS...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-12 F-12 IDEALARC CV-400 FIGURE F.2 – CONTROL TRANSFORMER X1 AND X2 TEST CONNECTIONS CONTR...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-14 F-14 IDEALARC CV-400 INPUT CONTACTOR TEST (continued) FIGURE F.3 – INPUT CONTACTOR CON...
TEST FOR CONTACT CONTINUITY 1. Disconnect the main input supply power to the machine. 2. Remove the two leads connected to the input con- tactor coil, #233 and X1/#232. See Figure F.4 forlocation. 3. Using the external 120VAC supply, apply 120VAC to the terminals of the input contactor coil. If the ...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-17 F-17 IDEALARC CV-400 TEST PROCEDURE 1. Set the ON/OFF power switch to OFF. 2. Disconne...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-18 F-18 IDEALARC CV-400 8. Read the meter. a. If proper voltage is present for all threep...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-19 F-19 IDEALARC CV-400 12. Test for 115VAC between leads #31 and #32 on the terminal str...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-20 F-20 IDEALARC CV-400 Plug P1 PHASE ANGLE WINDING VOLTAGES From Lead # To Lead # Expect...
STATIC SCR/DIODE RECTIFIER BRIDGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performed on this equipment may result in danger to the technician ormachine operator and will invalidate your factory warranty. For your safety and t...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-22 F-22 IDEALARC CV-400 STATIC SCR/DIODE RECTIFIER BRIDGE TEST (continued) FIGURE F.9 – C...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-23 F-23 IDEALARC CV-400 STATIC SCR/DIODE RECTIFIER BRIDGE TEST (continued) 8. Remove any ...
ACTIVE SCR TEST Service and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performed on this equipment may result in danger to the technician ormachine operator and will invalidate your factory warranty. For your safety and to avoid elec-trical sho...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-25 F-25 IDEALARC CV-400 ACTIVE SCR TEST (continued) TEST PROCEDURE 1. Disconnect the main...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-26 F-26 IDEALARC CV-400 ACTIVE SCR TEST (continued) 8. Remove any red insulating paint fr...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-27 F-27 IDEALARC CV-400 ACTIVE SCR TEST (continued) 9. Construct the circuit shown in Fig...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-28 F-28 IDEALARC CV-400 This is the typical DC open circuitvoltage waveform generated fro...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-29 F-29 IDEALARC CV-400 This is the typical DC open circuitvoltage waveform generated fro...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-30 F-30 IDEALARC CV-400 This is the typical SCR gate pulsevoltage waveform. The machine w...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-31 F-31 IDEALARC CV-400 This is NOT the typical DC outputvoltage waveform. One output SCR...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-33 F-33 IDEALARC CV-400 INPUT CONTACTOR (CR1) CLEANING/REPLACEMENT (continued) FIGURE F.1...
FAN MOTOR AND BLADE REMOVAL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performed on this equipment may result in danger to the technician ormachine operator and will invalidate your factory warranty. For your safety ...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-35 F-35 IDEALARC CV-400 FAN MOTOR AND BLADE REMOVAL AND REPLACEMENT (continued) FIGURE F....
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-37 F-37 IDEALARC CV-400 SCR/DIODE RECTIFIER ASSEMBLY REMOVAL AND REPLACEMENT (continued) ...
SCR REMOVAL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performed on this equipment may result in danger to the technician ormachine operator and will invalidate your factory warranty. For your safety and to avoid ele...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-39 F-39 IDEALARC CV-400 FIGURE F.20 – SCR DETAILS SCR REMOVAL AND REPLACEMENT (continued)...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-40 F-40 IDEALARC CV-400 FIGURE F.21 – 1/2” WIDE LEAF SPRING FIGURE F.22 – CLAMP ASSEMBLY ...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-41 F-41 IDEALARC CV-400 SCR REMOVAL AND REPLACEMENT (continued) CLAMPING PROCEDURE FOR 1/...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-42 F-42 IDEALARC CV-400 SCR REMOVAL AND REPLACEMENT (continued) PROCEDURE FOR THE5/8 INCH...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-43 F-43 IDEALARC CV-400 CLAMPING PROCEDURE FOR 1/4-28 CAP SCREWS NOTE: This procedure can...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-45 F-45 IDEALARC CV-400 PROCEDURE 1. Remove the main input supply power to themachine. 2....
MAIN TRANSFORMER REMOVAL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory trained personnel.Unauthorized repairs performed on this equipment may result in danger to the technician ormachine operator and will invalidate your factory warranty. For your safety and...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-47 F-47 IDEALARC CV-400 REMOVAL OF LIFT BAIL 1. Remove the main input supply power to the...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-48 F-48 IDEALARC CV-400 FIGURE F.26 – CHOKE REMOVAL GLASTIC STIFFENERS CHOKELEADS TOP"...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-49 F-49 IDEALARC CV-400 FIGURE F.27 – EPOXY MIX APPLICATION AREAS MAIN TRANSFORMER REMOVA...
3. Install the bottom primary coils, one on each of the three legs of the bottom iron assembly. The coilsmust be in correct position (left, center, right).Place the coils so that the leads come out at theback of the machine. See Figure F.28 for properpositioning. 4. Place insulation (Lincoln Electri...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-51 F-51 IDEALARC CV-400 MAIN TRANSFORMER REMOVAL & REPLACEMENT (continued) 10. Mount ...
REASSEMBLING THE MAINTRANSFORMER INTO THE MACHINE NOTE: The following procedure assumes you have completely reassembled the transformer coilsas described in the procedure above. Thelower iron has remained in place in themachine. See Figures F.25 and F.26. 1. Attach the bottom choke lead to the negat...
Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC TROUBLESHOOTING & REPAIR F-53 F-53 IDEALARC CV-400 RETEST AFTER REPAIR Retest a machine: • If it is rejected under t...
ELECTRICAL DIAGRAMS G-1 G-1 IDEALARC CV-400 Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Electrical Diagrams Section ...........................................................................................................Section G Wiring Diagram (Codes 1...
ELECTRICAL DIAGRAMS G-6 G-6 IDEALARC CV-400 Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Section TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC Retur n to Master TOC I T E M P A R T N O . R E Q D D E S C R I P T I O N C 1 , C 2 , C 3 3 2 33 2...
Lincoln Electric Manuals
-
Lincoln Electric 305G
Manual
-
Lincoln Electric IM646-A
Manual
-
Lincoln Electric 309
Manual
-
Lincoln Electric MB232
Manual
-
Lincoln Electric IM889-A
Manual
-
Lincoln Electric AC-1200
Manual
-
Lincoln Electric L12810-6
Manual
-
Lincoln Electric S350
Manual
-
Lincoln Electric 248HO
Manual
-
Lincoln Electric IM794
Manual
-
Lincoln Electric 350
Manual
-
Lincoln Electric IM690-A
Manual
-
Lincoln Electric 300 D
Manual
-
Lincoln Electric TIG 175 PRO
Manual
-
Lincoln Electric SVM103-A
Manual
-
Lincoln Electric IM834-B
Manual
-
Lincoln Electric LA-17
Manual
-
Lincoln Electric IM972
Manual
-
Lincoln Electric 250LX
Manual
- Lincoln Electric SVM194-A Manual