Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FOR ENGINEpowered equipment. 1.a. T u r n t h e e n g i n e o f f b e f o r e t r o u - bleshooting and maintenance work unless the maintenancework requires it to be running. _________________________________________...
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F U M E S A N D G A S E Scan be dangerous. 5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing thesef u m e s a n d g a s e s . W h e n w e l d i n g , k e e pyour head out of the fume. Use ...
F O R E L E C T R I C A L LYp o w e r e d e q u i p m e n t . 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’srecommendations. 8.c...
SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent d a n s c e m a n u e l a u s s i b i e n q u e l e s p r é c a u t i o n s d e s û r e t é générales suivantes: Sûreté Pour Soudage A L’Ar...
v IDEALARC DC - 1000 MASTER TABLE OF CONTENTS FOR ALL SECTIONS Page Safety .....................................................................................................................................................i - iv Installation ...........................................................
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IDEALARC DC-1000 A-1 TABLE OF CONTENTS -INSTALLATION SECTION- INSTALLATION..................................................................................Section A Technical Specifications ............................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Duty Cycle Amps Volts at Rated Amperes 100% 1000 44 60% 1140 44 55% 1250 44 Mode Current Range Maximum Open Auxiliary Constant C...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC A-3 INSTALLATION IDEALARC DC-1000 R e a d e n t i r e I n s t a l l a t i o n S e c t i o n b e f o r e i n s t a l l i n gthe I...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INSTALLATION IDEALARC DC-1000 A-4 FUSE AND WIRE SIZES Protect the input circuit with the super lag fuses ordelay type circuit br...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION FOR UNDER 300 VOLTS 1. Mount the movable reconnect panel to the stationaryreconnect panel studs in the position shown...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INSTALLATION IDEALARC DC-1000 A-6 CONNECTION FOR 380 VOLTS 1. Mount the movable reconnect panel to the stationaryreconnect panel...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC A-7 INSTALLATION IDEALARC DC-1000 All input power must be electrically disconnected before touching panel. _____________________...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INSTALLATION IDEALARC DC-1000 A-8 OUTPUT CONNECTIONS See Table A.1 for recommended IDEALARC DC-1000cable sizes for combined leng...
A-9 INSTALLATION IDEALARC DC-1000 A-9 CONNECTION FOR AIR/CARBON ARCCUTTING OPERATION THE OUTPUT TERMINALS ARE ENERGIZED ATA L L T I M E S W H E N T H E I D E A L A R C D C - 1 0 0 0 I SCONNECTED FOR AIR/CARBON ARC CUTTING. ____________________________________________________ 1. Set ON/OFF PUSH BUTTO...
A-10 NOTES IDEALARC DC-1000 A-10 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IDEALARC DC-1000 B-1 TABLE OF CONTENTS -OPERATION SECTION- OPERATION...................................................................................................................................Section B Safety ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERATION B-2 IDEALARC DC-1000 Read and understand this entire section beforeoperating your machine. SAFETY INSTRUCTIONS Only qu...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-3 OPERATION GENERAL DESCRIPTION The IDEALARC DC-1000 is an SCR-controlled, threephase, welding and cutting power source. It us...
B-4 OPERATION B-4 • Three circuit solid state control system providesmaximum performance and circuit protection. • Low profile case provides maximum use of space. • Convenient access to all controls. • Large output lead strain relief openings to preventterminal and cable damage. • Easily removed cas...
B-5 OPERATION B-5 1. ON/OFF PUSH BUTTON: This push button turnsthe machine ON or OFF 2. OUTPUT CONTROL POTENTIOMETER: Thiscontrol provides tapered, continuous control of themachine output. The control can be rotated fromminimum to maximum while machine is underload to adjust the machine output. 3. W...
B-6 OPERATION B-6 OPERATING STEPS The following procedures are for using the IDEALARCDC-1000 in the local control mode of operation. Forr e m o t e c o n t r o l o f t h e m a c h i n e , s e e t h e R e m o t eControl of Machine Operation section. Before operating the machine, make sure you have al...
B-7 OPERATION B-7 G O O D A R C S T R I K I N G G U I D E L I N E S F O R T H ENA-3 WITH THE IDEALARC DC-1000 IN THE CVINNERSHIELD®, CV SUBMERGED ARC OR VV(CC) WELDING MODES. Following are some basic arc striking techniques thatapply to all wire feed processes. Using these proce-dures should provide...
B-8 OPERATION B-8 c. Set NA-3 Start Board current and voltageas close to the welding procedure currentand voltage as possible. NOTE: The Start Board current and volt-age should be as close as possible to thewelding procedure current and voltage,w h i l e s t i l l g e t t i n g s a t i s f a c t o r...
C-1 ACCESSORIES C-1 IDEALARC DC-1000 TABLE OF CONTENTS -ACCESSORIES SECTION- ACCESSORIES ........................................................................................................................Section C Options/Accessories ................................................................
C-2 ACCESSORIES C-2 OPTIONS/ACCESSORIES • Remote Control Box Assembly (K775) • LN-7 • LN-8 } Semi-Automatic Wire Feeders • LN-9 • NA-3 • NA-5 } Automatic Wire Feeders • LT-7 and LT-56 Tractors METERS Optional factory-installed voltmeter and ammeter areavailable. REMOTE OUTPUT CONTROL -(OPTIONAL) The...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC C-4 ACCESSORIES C-4 NOTE: The connection diagram shown in Figure C.2shows the electrode connected for positive polarity.To chang...
C-5 ACCESSORIES C-5 CONNECTING THE LN-9 WIRE FEEDERTO THE IDEALARC DC-1000 1. Set the ON/OFF PUSH BUTTON to the OFF pos-tion. 2. Disconnect AC input power to the IDEALARC DC-1000. 3. Connect the wire feeder control cable leads to theDC-1000 terminal strip. See Figure C.4. 4. Connect the wire feeder ...
D-1 MAINTENANCE D-1 IDEALARC DC - 1000 TABLE OF CONTENTS -MAINTENANCE SECTION- MAINTENANCE ...................................................................................................Section D Safety Precautions.....................................................................................
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 3. Inspect the electrode cables for any slits or punc-tures in the cable jacket, or any condition thatwould affect the proper op...
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC E-1 THEORY OF OPERATION E-1 IDEALARC DC-1000 TABLE OF CONTENTS -THEORY OF OPERATION SECTION- THEORY OF OPERATION SECTION. ................................................................Section E General Description ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC E-2 THEORY OF OPERATION E-2 I N P U T L I N E V O LTA G E , C O N TA C -T O R , A N D M A I N T R A N S F O R M E R The desired ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC E-5 THEORY OF OPERATION E-5 SCR OPERATION A silicon controlled rectifier (SCR) is a three termi-nal device used to control rathe...
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IDEALARC DC-1000 F-1 TROUBLESHOOTING & REPAIR F-1 TABLE OF CONTENTS -TROUBLESHOOTING AND REPAIR SECTION- TROUBLESHOOTING AND REPAIR SECTION ...............................................................Section F...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IDEALARC DC-1000 F-2 TROUBLESHOOTING & REPAIR F-2 This Troubleshooting Guide is provided tohelp you locate and repair possib...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IDEALARC DC-1000 F-3 TROUBLESHOOTING & REPAIR F-3 _______________________________ CAUTION: Sometimes machine failures appear...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Linco...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-8 TROUBLESHOOTING & REPAIR F-8 IDEALARC DC-1000 Observe all Safety Guidelines detailed throughout this manual OUTPUT PROBL...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-9 TROUBLESHOOTING & REPAIR F-9 IDEALARC DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any r...
F-10 TROUBLESHOOTING & REPAIR F-10 IDEALARC DC-1000 Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln ElectricService Department for technical troubleshoo...
F-11 TROUBLESHOOTING & REPAIR F-11 IDEALARC DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln ElectricService Department for technical troublesho...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-12 TROUBLESHOOTING & REPAIR F-12 IDEALARC DC-1000 Observe all Safety Guidelines detailed throughout this manual If for any...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC IDEALARC DC-1000 F-13 TROUBLESHOOTING & REPAIR F-13 TEST DESCRIPTION This test will determine if the correct voltage is bein...
F-14 TROUBLESHOOTING & REPAIR F-14 TEST PROCEDURE 1. Disconnect main AC input power tothe machine. 2. Remove the Top and Case Sides. 3. Locate the Control Transformer (T2)on the left side of the Input Box (fac-ing the back of the machine). SeeFigure F.1. 4. Locate the Control Transformerprimary ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-15 TROUBLESHOOTING & REPAIR F-15 5. Locate Control Transformer leadsX1 and X2 at in line connectors.See Figure F.2. 6. App...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Service and repair should be performed only by Lincoln Electric factory trained personnel.Unauthorized repairs performed on this...
F-17 TROUBLESHOOTING & REPAIR F-17 TEST DESCRIPTION 1. Disconnect main AC input power tothe machine. 2. I n s p e c t t h e I n p u t C o n t a c t o r ,Reconnect Panel, and primary leadsto the Main Transformer for loose orfaulty connections. See Figure F.3. 3. Apply input power, push start butt...
F-18 TROUBLESHOOTING & REPAIR F-18 a. If one or more of the abovevoltage tests are incorrect,c h e c k f o r l o o s e o r f a u l t ywiring. If the wiring is good,then the Main Transformermay be faulty. NOTE: A long wire with clip or al o n g p r o b e m a y b e r e q u i r e d t or e a c h t h...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-19 TROUBLESHOOTING & REPAIR F-19 MAIN TRANSFORMER (T1) VOLTAGE TEST IDEALARC DC-1000 From To Expected VAC Plug Pin Lead Pl...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-20 TROUBLESHOOTING & REPAIR F-20 FIRING BOARD TEST IDEALARC DC-1000 Service and repair should be performed only by Lincoln...
F-21 TROUBLESHOOTING & REPAIR F-21 TEST PROCEDURE FORNORMAL FIRINGBOARD OPERATION 1. Disconnect main AC input power tothe machine. 2. Remove screws, loosen and lowerthe front panel to access the FiringBoard on the left side of ControlBox facing the machine. 3. Visually inspect the Firing Boardf ...
F-22 TROUBLESHOOTING & REPAIR F-22 10. Rotate the output control poten - tiometer (R1). As the potentiometeri s t u r n e d c l o c k w i s e , t h e L E D sshould glow brighter. As the poten-tiometer is turned counter-clock-wise, the LEDs should dim. a. I f t h e L E D s g l o w a n dchange in ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-23 TROUBLESHOOTING & REPAIR F-23 15. Test the Output Pilot Relay (4CR) f o r o p e r a t i o n b y r e m o v i n g a n dre...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-24 TROUBLESHOOTING & REPAIR F-24 FIRING BOARD TEST IDEALARC DC-1000 TABLE F.1 - LED 7, 8 and 9 Check List IF LED 7 is ON L...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-25 TROUBLESHOOTING & REPAIR F-25 IDEALARC DC-1000 CONTROL BOARD TEST Service and repair should be performed only by Lincol...
F-26 TROUBLESHOOTING & REPAIR F-26 TEST PROCEDURE FORNORMAL CONTROL BOARDOPERATION 1. Remove main supply power to theDC-1000. 2. Remove screws, loosen and lowert h e F r o n t P a n e l t o a c c e s s a n dinspect the Control Board locatedin the right front control box. SeeFigure F.9. 3. Apply ...
F-28 TROUBLESHOOTING & REPAIR F-28 IF LED 2 does not light when #2 and#4 are jumpered together. 1. Check for the presence of open cir-cuit voltage at the weld output ter-minals (27 to 75 VDC in constantvoltage mode, 75 VDC in constantcurrent mode). a. I f o p e n c i r c u i t v o l t a g e I Sp...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-30 TROUBLESHOOTING & REPAIR F-30 IDEALARC DC-1000 Service and repair should be performed only by Lincoln Electric factory ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-33 TROUBLESHOOTING & REPAIR F-33 5. Repeat Step 4 testing SCR 2, SCR3 , S C R 4 , S C R 5 , a n d S C R 6 . To further che...
F-34 TROUBLESHOOTING & REPAIR F-34 IDEALARC DC-1000 Service and repair should be performed only by Lincoln Electric factory trained personnel.Unauthorized repairs performed on this equipment could result in danger to the technician orthe machine operator and will invalidate your factory warranty...
F-35 TROUBLESHOOTING & REPAIR F-35 1. Remove main supply power to theDC-1000. 2. Remove all Molex plugs from theF i r i n g B o a r d a n d C o n t r o l B o a r d .See Figure F.15. ACTIVE SCR TEST IDEALARC DC-1000 Return to Section TOC Return to Section TOC Return to Section TOC Return to Secti...
F-36 TROUBLESHOOTING & REPAIR F-36 3. R e m o v e t h e r e d i n s u l a t i n g p a i n tf r o m h e a t s i n k t e s t p o i n t s . S e eFigure F.16. 4. Perform test procedure as follows.Refer to Figure F.17. Repeat testfor all six SCRs. NOTE: Do not disassemble the heatsinks. ACTIVE SCR TE...
F-37 TROUBLESHOOTING & REPAIR F-37 5. To test SCRs, construct the circuitoutlined in Figure F.17. Use one 6Vlantern battery. Resistor values arein ohms ±10%. The voltmeter scaleshould be low, approximately 0-5 or0-10 volts. BATTERY TEST Check the battery by shorting leads (A)and (C) and then clo...
TROUBLESHOOTING & REPAIR F-38 NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM CONSTANT CURRENT MODE - NO LOAD IDEALARC DC-1000 Volts/Div . . . . . . . . . . . . . 50 V/Div.Horizontal Sweep . . . . . 2 ms/Div.Coupling . . . . . . . . . . . . . . . . . DCTrigger . . . . . . . . . . . . . . . Internal SCOPE S...
F-41 TROUBLESHOOTING & REPAIR TYPICAL OUTPUT VOLTAGE WAVEFORM -MACHINE LOADED CONSTANT VOLTAGE INNERSHIELD MODE IDEALARC DC-1000 Volts/Div . . . . . . . . . . . . . 20 V/Div.Horizontal Sweep . . . . . 2 ms/Div.Coupling . . . . . . . . . . . . . . . . . DCTrigger . . . . . . . . . . . . . . . Int...
F-42 TROUBLESHOOTING & REPAIR F-42 TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED - 500 AMP OUTPUT TERMINAL CONSTANT VOLTAGE INNERSHIELD MODE IDEALARC DC-1000 Volts/Div . . . . . . . . . . . . . 20 V/Div.Horizontal Sweep . . . . . 2 ms/Div.Coupling . . . . . . . . . . . . . . . . . DCTrigger ....
F-43 TROUBLESHOOTING & REPAIR F-43 TYPICAL SCR GATE VOLTAGE WAVEFORM CONSTANT VOLTAGE INNERSHIELD MAXIMUM OUTPUT SETTING - NO LOAD IDEALARC DC-1000 SCOPE SETTINGS Volts/Div . . . . . . . . . . . . . . 1 V/Div.Horizontal Sweep . . . . . .5 ms/Div.Coupling . . . . . . . . . . . . . . . . . DCTrigg...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-44 TROUBLESHOOTING & REPAIR F-44 ABNORMAL OPEN CIRCUIT VOLTAGE WAVEFORM CONSTANT VOLTAGE INNERSHIELD ONE OUTPUT SCR NOT FU...
F-46 TROUBLESHOOTING & REPAIR F-46 CLEANING PROCEDURE 1. Remove main input supply power tothe DC-1000 and remove case topand sides. 2. Locate the input contactor. Using a1/2” wrench, remove the cover plate f r o m t h e i n p u t c o n t a c t o r . M a r k ,label, and remove leads as neces-s a ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-47 TROUBLESHOOTING & REPAIR F-47 DO NOT APPLY INPUT POWER TO T H E D C - 1 0 0 0 W I T HT H E C O N T A C T O RC O V E R P...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REPAIR F-49 IDEALARC DC-1000 Service and repair should be performed only by Lincoln Electric factory train...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-50 TROUBLESHOOTING & REPAIR SCR OUTPUT BRIDGEREMOVAL 1. Remove input power to machine. 2. Using a 5/16 (8mm) nut driver or...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REPAIR F-51 10. C u t a n y n e c e s s a r y c a b l e t i e s t o allow for the SCR bridge assemblyremov...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-52 TROUBLESHOOTING & REPAIR REMOVAL OF INDIVIDUALSCR HEAT SINK ASSEMBLIES 1. Using a 9/16” wrench, remove twonuts, flat wa...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-54 TROUBLESHOOTING & REPAIR 7. Using a 3/8” socket wrench, attachthe two screws (one on each side)holding the SCR assembly...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REPAIR F-55 IDEALARC DC-1000 Service and repair should be performed only by Lincoln Electric factory train...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-56 TROUBLESHOOTING & REPAIR REMOVAL OF LIFT BAIL 1. Remove input power to machine. 2. Using a 5/16 (8mm) nut driver or fla...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-58 TROUBLESHOOTING & REPAIR IDEALARC DC-1000 Service and repair should be performed only by Lincoln Electric factory train...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REPAIR F-59 MAIN TRANSFORMER DISASSEMBLY AND ASSEMBLY IDEALARC DC-1000 FIGURE F.26 - Main Transformer Disa...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-60 TROUBLESHOOTING & REPAIR MAIN TRANSFORMERDISASSEMBLY 1. P e r f o r m L i f t B a i l R e m o v a l Procedure. 2. Remov...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REPAIR F-61 TRANSFORMERREASSEMBLY 1. Using a hoist, carefully lift the topiron onto the assembly. Lightly ...
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-63 TROUBLESHOOTING & REPAIR OPEN CIRCUIT VOLTAGES Mode Input Hertz Open Circuit Volts Variable Voltage 60 74/76 DC Auxilia...
G-1 ELECTRICAL DIAGRAMS G-1 IDEALARC DC-1000 TABLE OF CONTENTS -ELECTRICAL DIAGRAMS SECTION- DIAGRAMS........................................................................................Section GWiring Diagram (Codes 9919, 9920) ...........................................................G-2Operat...
G-3 ELECTRICAL DIAGRAMS IDEALARC DC1000 Operating Schematic T S 2 2 1 4 2 3 1 3 2 T S 3 R 1 S 4 - A S 4 - C C V I C V I C V S C V S S 3 2 C R L 1 L 2 L 3 1 C R S T A R T S T O P R 1 C R 2 C R S E C O N D A R Y P R I M A R Y S H U N T 2 1 5 2 1 5 2 1 0 2 1 0 2 2 6 2 3 8 7 5 3 C R 2 2 0 2 1 5 C U R R ...
Lincoln Electric Manuals
-
Lincoln Electric 305G
Manual
-
Lincoln Electric IM646-A
Manual
-
Lincoln Electric 309
Manual
-
Lincoln Electric MB232
Manual
-
Lincoln Electric IM889-A
Manual
-
Lincoln Electric AC-1200
Manual
-
Lincoln Electric L12810-6
Manual
-
Lincoln Electric S350
Manual
-
Lincoln Electric 248HO
Manual
-
Lincoln Electric IM794
Manual
-
Lincoln Electric 350
Manual
-
Lincoln Electric IM690-A
Manual
-
Lincoln Electric 300 D
Manual
-
Lincoln Electric TIG 175 PRO
Manual
-
Lincoln Electric SVM103-A
Manual
-
Lincoln Electric IM834-B
Manual
-
Lincoln Electric LA-17
Manual
-
Lincoln Electric IM972
Manual
-
Lincoln Electric 250LX
Manual
- Lincoln Electric SVM194-A Manual