Page 2 - SAFETY; ELECTRIC SHOCK can kill.; WARNING
i SAFETY i PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDRENAWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING. Read and understand the following safety highlights. For additional safety information it is strongly recommended that you pur-chase a...
Page 3 - ELECTRIC AND MAGNETIC FIELDS
ii SAFETY ii FOR ELECTRICALLYpowered equipment. 6.a. Turn off input power using the disconnectswitch at the fuse box before working on theequipment. 6.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s rec-ommendations. 6.c. Ground the e...
Page 4 - NOTES
Page 5 - PRÉCAUTIONS DE SÛRETÉ
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la seco...
Page 6 - Thank You; Please Examine Carton and Equipment For Damage Immediately
PLASMA TORCH v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product •••as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Sav...
Page 7 - TABLE OF CONTENTS
PLASMA TORCH TABLE OF CONTENTS Page SPECIFICATION SUMMARY ........................................................................................................A-1 GENERAL DESCRIPTION ............................................................................................................A-2 IN...
Page 8 - INSTALLATION; SPECIFICATIONS SUMMARY; OUTPUT RATING
A-1 INSTALLATION PLASMA TORCH A-1 SPECIFICATIONS SUMMARY K880-1 PCT125 Hand-held Plasma Torch with 25 ft. (7.6m) cable K880-2 PCT125 Hand-held Plasma Torch with 50 ft. (15.2m) cable K880-3 PCT125M Plasma Machine Torch with 50 ft (15.2m) cable and 24 and 32 pitch gear racks K880-4 PCT125M Robotic Pla...
Page 9 - GENERAL DESCRIPTION
A-2 INSTALLATION PLASMA TORCH A-2 GENERAL DESCRIPTION The Magnum PCT125/PCT125M plasma torches havebeen designed for use on a Pro-Cut 125. All of thetorches are single gas, air-cooled. The torches aresupplied factory mounted to the Pro-Cut or can bebought as individual units. The hand-held torch is ...
Page 11 - OPERATION
B-1 OPERATION B-1 OPERATION Refer to your Pro-Cut operator’s manual for completeoperating information. When plasma cutting, it is necessary to wearproper eye, head and body protection. A. Connect the work lead to the material to be cut. B. Assemble an electrode, swirl ring, nozzle and shield cup on ...
Page 12 - MAINTENANCE
C-1 MAINTENANCE C-1 MAINTENANCE ELECTRIC SHOCK CAN KILL• Only qualified personnel should per- form this installation. • Turn the input power OFF at the dis- connect switch or fuse box beforeworking on this equipment. • Do not touch electrically hot parts.• Do not operate with covers removed. Keep th...
Page 16 - TROUBLESHOOTING; CAUTION; HOW TO USE TROUBLESHOOTING GUIDE
PLASMA TORCH D-1 TROUBLESHOOTING D-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting G...
Page 17 - FUNCTION PROBLEMS
D-2 TROUBLESHOOTING D-2 PLASMA TORCH Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting...