Page 2 - TABLE OF CONTENTS
TABLE OF CONTENTS SAFETY INSTRUCTIONS .............................................................. 3 IMPORTANT SAFETY INSTRUCTIONS ..........................................................4 PRODUCT OVERVIEW .................................................................. 8 Exterior Parts .........
Page 3 - SAFETY INSTRUCTIONS; READ ALL INSTRUCTIONS BEFORE USE
3 EN SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USE Your safety and the safety of others are very important.We have provided many important safety messages in this manual and on your appliance. Always read and follow all safety messages. This is the safety alert symbol.This symbol alerts you t...
Page 4 - IMPORTANT SAFETY INSTRUCTIONS; WARNING; including the following:
4 EN IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of explosion, fire, death, electric shock, scalding or injury to persons when using this product, follow basic precautions, including the following: INSTALLATION • Before use, the appliance must be properly installed as described in this ...
Page 6 - CAUTION; To reduce the risk of minor or moderate injury to persons,; INSTALLATION
6 EN CAUTION To reduce the risk of minor or moderate injury to persons, malfunction, or damage to the product or property when using this product, follow basic precautions, including the following: INSTALLATION • Take care when installing the product that exhaust or condensation does not damage near...
Page 7 - SAVE THESE INSTRUCTIONS
7 EN REFRIGERANT (FOR R32 ONLY) WARNING • Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. • The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition so...
Page 8 - PRODUCT OVERVIEW; Exterior Parts
8 EN PRODUCT OVERVIEW Exterior Parts Interior Parts Remote Control Evaporator Horizontal Air Deflector (Vertical Louver) Air Guide Vertical Air Deflector (Horizontal Louver) Condenser Air Filter Compressor Control Panel Base Pan Cabinet Power Cord Front Grille
Page 9 - Electrical Data
9 EN INSTALLATION Electrical Data The power cord may include a current interrupter device. TEST and RESET buttons are provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RES...
Page 10 - Installation Requirements; Electrical Service
10 EN Installation Requirements Remove packing materials from the wall sleeve and tape from the air conditioner. • If you use an existing wall sleeve, you should measure its dimensions.Install the new air conditioner according to these installation instructions to achieve the best performance. All w...
Page 11 - Items in Installation Hardware; How to Install; NOTE
11 EN • Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time. • Handle Air Conditioner with care.Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear co...
Page 12 - Procedure A
12 EN 4 Wall sleeve must be securely fastened in wall before installing the Air Conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed. 5 Prepare the wall sleeve for installation of the unit. If you plan to use your existing wall sleeve, and it is not LGE,...
Page 13 - Procedure B
13 EN 3 Remove the backing from the vertical insulation strip 15-9/16” x 1-3/8” x 1-3/8” and attach that to the inside right of the sleeve as shown below. Remove the backing from the around insulation strip 67-1/8” x 1-3/8” x 25/32” and attach that to the inside front of the sleeve as shown below. A...
Page 15 - Procedure C
15 EN Procedure C 1 Redirect the louvers at the back of the wall sleeve to 60° angle as shown in the Figure 15. The use of pliers is recommended. Figure 15 Rear Louvers (Top View) 60° 60° 7 3/32 " 2 If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a ...
Page 16 - Attach Front Grille to
16 EN 7 To achieve rearward slope for unit draining, remove the backing from the 11-13/16 “ shim strips and attach them as shown below in Figure 22. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve. Figure 21 Figure 22 1" high 3 / 4 " High Shim (2EA) ...
Page 17 - OPERATION; Control Panel and Remote Control
17 EN OPERATION Control Panel and Remote Control Control Panel Remote Control NOTE • The feature may be changed according to the type of model. • On control panel surface have protection film, Please remove film before use. Power Press to turn the air conditioner ON or OFF. Operation Mode Press the ...
Page 18 - Wireless Remote Control; Inserting Batteries
18 EN Temperature Control The thermostat monitors room temperature to maintain the desired temperature. The thermostat can be set between 60 °F–86 °F (16 °C–30 °C). Press or arrows to increase or decrease temperature setting. Clean Filter The Clean Filter LED lights up to notify you that the filter ...
Page 19 - Air Direction; Adjusting Horizontal Airflow; Additional Features; Slinger Fan
19 EN Air Direction Airflow can be adjusted by changing the direction of the air conditioner’s louvers. Adjusting Horizontal Airflow Direction The horizontal airflow is adjusted by moving the levers of the vertical louvers to the left or right. Adjusting Vertical Airflow Direction Touch the horizont...
Page 20 - MAINTENANCE; Cleaning; Cleaning the Air Filter
20 EN MAINTENANCE WARNING • Before cleaning or performing maintenance, disconnect the power supply and wait until the fan stops. Cleaning Check the air filter at least twice a month to see if cleaning is necessary. Trapped particles in the filter can build up and block the airflow, reducing cooling ...
Page 21 - TROUBLESHOOTING; Before Calling for Service; Normal Sounds You May Hear; High Pitched Chatter
21 EN TROUBLESHOOTING Before Calling for Service The appliance is equipped with an automatic error-monitoring system to detect and diagnose problems at an early stage. If the appliance does not function properly or does not function at all, check the following before you call for service. Normal Sou...
Page 24 - WARRANTY; WHAT THIS WARRANTY COVERS:
24 EN WARRANTY ARBITRATION NOTICE: THIS LIMITED WARRANTY CONTAINS AN ARBITRATION PROVISION THAT REQUIRES YOU AND LG TO RESOLVE DISPUTES BY BINDING ARBITRATION INSTEAD OF IN COURT, UNLESS YOU CHOOSE TO OPT OUT. IN ARBITRATION, CLASS ACTIONS AND JURY TRIALS ARE NOT PERMITTED. PLEASE SEE THE SECTION TI...
Page 25 - HOW TO OBTAIN WARRANTY SERVICE & ADDITIONAL INFORMATION:; FOR YOUR RECORDS
25 EN THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING AND WITHOUT LIMITATION TO, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW, THIS WARRANTY IS LIMITED IN DURATION TO THE TERM PERIOD EXPRESSED...
Page 26 - PROCEDURE FOR RESOLVING DISPUTES:; Agreement to Binding Arbitration and Class Action Waiver.; Arbitration Rules and Procedures.
26 EN PROCEDURE FOR RESOLVING DISPUTES: ALL DISPUTES BETWEEN YOU AND LG ARISING OUT OF OR RELATING IN ANY WAY TO THIS LIMITED WARRANTY OR THE PRODUCT SHALL BE RESOLVED EXCLUSIVELY THROUGH BINDING ARBITRATION, AND NOT IN A COURT OF GENERAL JURISDICTION. BINDING ARBITRATION MEANS THAT YOU AND LG ARE E...
Page 27 - Hearings and Location.
27 EN Fees/Costs. You do not need to pay any fee to begin an arbitration. Upon receipt of your written demand for arbitration, LG will promptly pay all arbitration filing fees to the AAA unless you seek more than $25,000 in damages, in which case the payment of these fees will be governed by the AAA...