Page 2 - I N T R O D U C T I O N
I N T R O D U C T I O N IMPORTANT SAFETY INSTRUCTIONS Basic Safety Precautions . . . . . . . . . . . . . . . . . . . . . . 3 - 6Electrical Safety. . . . . . . . . . . . . . . . . . . . . . . . . .. . . . .6, 7 CARE AND CLEANING Storing the Air Condition er PARTS AND FEATURES Key Parts and Components...
Page 3 - I M P O R T A N T S A F E T Y I N S T R U C T I O N S; English; Do not store flammables like; BASIC SAFETY PRECAUTIONS
I M P O R T A N T S A F E T Y I N S T R U C T I O N S 3 English English Do not store flammables like gasoline benzene thinner etc. near the air conditioner. BASIC SAFETY PRECAUTIONS
Page 6 - ELECTRICAL SAFETY; WARNING; Electrical Shock Hazard
I M P O R T A N T S A F E T Y I N S T R U C T I O N S 6 If the liquid from the battery gets onto your skin or clothers , wash it well with clean water. Do not use the remote if the battery has leaked. y If you eat the liquid from the battery,brush your teeth and see doctor.Do not use theremote if th...
Page 7 - READ ALL INSTRUCTIONS BEFORE USE; INTEGRATED CIRCUIT BREAKER; SAVE THESE INSTRUCTIONS; PREFERRED; TEMPORARY GROUNDING
7 English I M P O R T A N T S A F E T Y I N S T R U C T I O N S READ ALL INSTRUCTIONS BEFORE USE For additional safety, the power cord features an integrated circuit breaker. Test and reset buttons are provided on the plug case. The circuit breaker should be tested periodically by pressing the TEST ...
Page 8 - KEY PARTS AND COMPONENTS; P A R T S A N D F E A T U R E S
1 2 3 4 5 6 7 KEY PARTS AND COMPONENTS CONTROL PANEL AND DISPLAY Easy-to-read white LCD display shows the operating state. Digital touch buttons make changing settings quick and easy. MOTORIZED AIR DISCHARGE The adjustable louvered air discharge opens automatically when the air conditioner is turned...
Page 10 - PREPARING FOR OPERATION; BEFORE USING YOUR AIR CONDITIONER; H O W T O U S E
Refer to the Installation Instructions included in this manual before using the air conditioner. Once the air conditioner has been properly assembled and installed: Plug the power cord into its own dedicated properly grounded outlet. Do not plug other it could overload the outlet and create a e haza...
Page 11 - CAUTION; INSERTING BATTERIES IN THE REMOTE; REMOTE STORAGE
11 2 3 CAUTION • If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water . Do not use the remote if the bat teries have leaked. • If you eat the liquid from the batteries, brush your teeth and see doctor. The chemicals in batteri es could cause bur ns or other ...
Page 12 - USING THE CONTROLS; ENERGY; MODE; COOL; HEAT
1 2 Press the POWER butto n to turn the air conditioner ON or OFF. When you turn the air c tone will play and the LCD display will show the set temperature and any active onditioner on, an ascending mode.The air discharge on the top of the air conditioner will automatically open. When turning the ai...
Page 15 - EXHAUST COMPONENTS; I N S T A L L A T I O N I N S T R U C T I O N S; PREPARING FOR INSTALLATION; The air conditioner is heavy! Use two or more people to
15 2 Type A Screws 1 Type B Screw 1 Type C Screw The following components are used for window venting. Not all components are used for every installation. EXHAUST COMPONENTS Window Installation Kit (includes 1 Window Vent Panel and 3 Extension Panels) Flexible Venting Hose 2 Type A Foam Seals (Adhes...
Page 16 - I N S T A L L A T I O N I N S T R U C T I O N S; SELECTION OF INSTALLATION LOCATION
I N S T A L L A T I O N I N S T R U C T I O N S SELECTION OF INSTALLATION LOCATION Place the unit on a level floor. For best performance,allow at least 20 in of air space on back side of the unit for good air circulation. 1 2 20 in 1 6 Place the unit near a window. The hose and diffuser will be used...
Page 17 - WINDOW VENT PANEL AND EXTENSIONS
I N S T A L L A T I O N I N S T R U C T I O N S WINDOW VENT PANEL AND EXTENSIONS The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18" to 50" wide, or casement-style windows from 18 " to 50 " high. For an 18" window opening, us...
Page 18 - INSTALLATION IN VERTICAL SLIDING WINDOWS
NOTE : The window installation kit can be used with vertical sliding windows between 18" and 50" wide. I N S T A L L A T I O N I N S T R U C T I O N S INSTALLATION IN VERTICAL SLIDING WINDOWS 18 Foam seal A(Adhesive type) Foam seal C(Adhesive type-shorter) Sellante de espuma A(Tipo adhesivo)...
Page 20 - INSTALLATION IN CASEMENT STYLE WINDOWS; I N S TA L L A T I O N I N S T R U C T I O N S
Foam seal A(Adhesive type) Foam seal C(Adhesive type-shorter) 1 Cut the foam seal A (adhesive type) & C (adhesive type-shorter) to the proper length, and attach it to the window sash and frame. 2 Insert the vent panel assembly, including extension panels, if needed, into the window opening. Exte...
Page 22 - INDOOR DRAINAGE; HEATING DRAINAGE
When you use heating function, draining water is needed. For cooling only function, you do not need to install this part. INDOOR DRAINAGE 1.Remove the water plug firstly on the back of the product. 2. Install end point of the drain pipe to the unit, and put the other end of the pipe into a bucket. (...
Page 23 - OUTDOOR DRAINAGE
OUTDOOR DRAINAGE CAUTION 23 I N S T A L L A T I O N I N S T R U C T I O N S 2. Install end point of the drain pipe to the unit, connect the other end pipe to the drain hole of the window panel. 1.Remove the water plug firstly. When water is being drained at the drain pipe, you can press TIMER and DO...
Page 24 - C A R E A N D C L E A N I N G; CLEANING THE AIR FILTER
C A R E A N D C L E A N I N G 24 Your air cond itioner is designed for year-round operation wit h only minimal cleaning and maintenance. For maximum efficiency, it is recommended that you have the cooling coils inspected an d cleaned annually. Your local LG Authorized Service Center can provide this...
Page 25 - C A R E A N D C L E A N I N G; EMPTYING THE WATER COLLECTION TANK; Using the upper drain port
C A R E A N D C L E A N I N G EMPTYING THE WATER COLLECTION TANK When the internal water collection tank is full, FL Using the upper drain port 25 English Install end point of the drain pipe to the unit, and put the other end of the pipe into a bucket. (Bigger than 28oz) Remove the water plug firstl...
Page 26 - Use Drain hose when use the DRY mode; COOL mode, with a temperature setting of 72°F.; FL apperars in the display
C A R E A N D C L E A N I N G Use Drain hose when use the DRY mode EMPTYING THE WATER COLLECTION TANK Unplug the air conditioner, disconnect the exhaust hose from the back, and move the air conditioner to a suitable drain location or outdoors. You may also place a pan under the drain that will hold ...
Page 27 - STORING THE AIR CONDITIONER
1 2 3 1 2 3 4 4 STORING THE AIR CONDITIONER If the air conditioner will not be used for an extened period of time: To drain the water collection tank completely, leave the bottom drain cap off long enough to allow any residual water to drain out. Once the tank is completely drained and no more water...
Page 28 - BEFORE CALLING FOR SERVICE; T R O U B L E S H O O T I N G
BEFORE CALLING FOR SERVICE T R O U B L E S H O O T I N G Before you call for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of a defect in workmanship or materials. Air conditioner does not start The air conditioner is unplu...
Page 30 - LG PORTABLE AIR CONDITIONER LIMITED
WARRANTY LG PORTABLE AIR CONDITIONER LIMITED WARRANTY - USA WHAT THIS WARRANTY COVERS:LG Electronics U.S.A., Inc. (“LG”) warrants your LG Portable Air Conditioner ("product") against defect in materials or workmanshipunder normal household use, during the warranty period set forth below, LG ...