Page 2 - Room Air Conditioner; Room Air Conditioner Ownerʼs Manual; TABLE OF CONTENTS; FOR YOUR RECORDS; READ THIS MANUAL; PRECAUTION
2 Room Air Conditioner Room Air Conditioner Ownerʼs Manual TABLE OF CONTENTS FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased n Staple your receipt to this page in the event you needit to pr...
Page 3 - ENGLISH; Safety Precautions; Be sure to follow the instruction.; Installation
Owner's Manual 3 Safety Precautions ENGLISH Safety Precautions To prevent the injury of the user or other people and property damage, the following instructions must befollowed. n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classifiedby the following...
Page 4 - Operation
4 Room Air Conditioner Safety Precautions Be cautious whenunpacking and installingthe product. • Sharp edges could cause injury. Be especially careful of thecase edges and the fins on thecondenser and evaporator. For installation, alwayscontact the dealer or anAuthorized Service Center. • There is r...
Page 8 - Disuse
8 Room Air Conditioner Safety Precautions Do not recharge ordisassemble the batteries.Do not dispose of batteriesin a fire. • They may burn or explode. If the liquid from the batteriesgets onto your skin or clothes,wash it well with clean water.Do not use the remote if thebatteries have leaked. • Th...
Page 9 - Prior to Operation; Preparing for Operation
Owner's Manual 9 ENGLISH Prior to Operation Prior to Operation 1. Contact an installation specialist for installation.2. Plug in the power plug properly.3. Use a dedicated circuit.4. Do not use an extension cord.5. Do not start/stop operation by plugging/unplugging the power cord.6. If the cord/plug...
Page 10 - Introduction; This symbol alerts you to the risk of electric shock.; Features; Indoor
10 Room Air Conditioner Introduction Introduction This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that may cause harm to theair conditioner. This symbol indicates special notes. NOTICE Features Symbols used in this Manual Signal Receptor Front Panel Air Discha...
Page 11 - Electrical Safety; • This appliance must be properly grounded.
Owner's Manual 11 ENGLISH Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the w...
Page 12 - Operating Instructions; How to insert the Batteries; Signal receptor
12 Room Air Conditioner On/Off : Lights up during the system operation, error code and auto restart setting. ��* Hot start operation: Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit. � * In defrost mode unit stops heating operation for few minutes...
Page 13 - Controls; Operation Mode; Remote Control Operations
Owner's Manual 13 ENGLISH Operating Instructions Controls ON OFF CANCEL SET ° C/ ° F AUTO CLEAN 1 3 5 4 9 10 12 18 16 7 2 8 13 15 11 6 Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Flip-up door�(opened) Heating Operation Signal transmitter • Cooling Model(� )...
Page 14 - Cooling; Cooling operation
14 Room Air Conditioner ON Cooling Healthy� Dehumidification Auto Heating� (Heat pump model only) To lower the temperature To raise the temperature Operating Instructions Press the Start/Stop button. The unit will respond with a beep. Open the door of the remote controller. To select Cooling Operati...
Page 15 - Auto
Owner's Manual 15 ENGLISH ON Cooling Healthy� Dehumidification Auto Heating� (Heat pump model only) To lower the temperature To raise the temperature Operating Instructions Press the Start/Stop button. The unit will respond with a beep. Open the door of the remote controller. To select Auto Operatio...
Page 16 - Auto Changeover
16 Room Air Conditioner ON Cooling Healthy� Dehumidification Auto� changeover Heating� (Heat pump model only) To lower the temperature To raise the temperature Operating Instructions Auto changeover operation (Optional) Press the Start/Stop button. The unit will respond with a beep. Open the door of...
Page 17 - Healthy; Healthy dehumidification operation
Owner's Manual 17 ENGLISH ON Cooling Healthy� Dehumidification Auto Heating� (Heat pump model only) Operating Instructions Press the Start/Stop button.The unit will respond with a beep. Open the door of the remote controller. To select Healthy Dehumidification Operation , press the Operation Mode Se...
Page 18 - Heating
18 Room Air Conditioner ON Cooling Healthy� Dehumidification Auto Heating� (Heat pump model only)� To lower the temperature To raise the temperature Operating Instructions Heating operation (Heat pump model only) Press the Start/Stop button.The unit will respond with a beep. Open the door of the rem...
Page 19 - or; Jet Cool; Jet cool operation
Owner's Manual 19 ENGLISH or or Operating Instructions o During the JET COOL function at any moment, the A/C starts to blow the cool air at extremelyhigh speed for 30 minutes setting the room temp. automatically to 64°F(18°C).It is especially used to cool the room temp. quickly in a hot summer. In h...
Page 20 - Jet Heat
20 Room Air Conditioner Cooling Heating� (Heat pump model only) Healthy� Dehumidification Auto� changeover ON or or Operating Instructions o During the JET HEAT function at any moment, the A/C starts to blow the heat air at extremely highspeed for 60 minutes setting the room temp. automatically to 8...
Page 21 - NEO PLASMA Air Purifying Operation only; NEO PLASMA purification operation(Optional)
Owner's Manual 21 ENGLISH Operating Instructions Press the Start/Stop button.The unit will respond with abeep. 1 Open the door of the remotecontroller. Press the PLASMAbutton.Operation will start when the buttonis pressed and stop when the buttonis pressed again. 2 Set the fan speed again with the d...
Page 22 - nd F operation; For more details, refer to functions next pages.
22 Room Air Conditioner ON OFF CANCEL SET ° C/ ° F AUTO CLEAN ON OFF SET Operating Instructions Press the Start/Stop button. The unit will respond with a beep. Open the door of the remote control and press the 2ndFunction button to operate functions printed in blue unterbuttons.(Check the indication...
Page 23 - Sleep mode; In cooling mode or healthydehumidification mode:; Setting the time; To cancel the timer setting; Additional Features
Owner's Manual 23 ENGLISH Delay OFF Timer Delay ON Timer Delay OFF and ON Timer Delay ON and OFF Timer Operating Instructions Sleep mode 1. Press the Sleep Mode Auto button to set the time you want the unit to stop automatically. 2. The Timer is programmed in one-hour increments by pressing the Slee...
Page 24 - AUTO CLEAN; Airflow direction control; Air circulation mode; Auto clean
24 Room Air Conditioner Fan speed is on low. Fan speed is on medium. Fan speed is on high. CHAOS Air AUTO CLEAN Operating Instructions o During Auto Clean function, moistures left in indoor units after Cooling Operation or HealthyDehumidification Operation can be removed. o During Auto Clean functio...
Page 25 - High�; Forced operation; Heat pump Model; Helpful information
Owner's Manual 25 ENGLISH High� Speed ON/OFF� button Operating Instructions Operation procedures when the remote control can't be used.The operation will be started if the power button is pressed.If you want to stop operation, re-press the button. Forced operation Auto restart In case the power come...
Page 26 - Maintenance and Service; Indoor Unit; Air Filters
26 Room Air Conditioner Maintenance and Service Maintenance and Service Indoor Unit Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any ...
Page 27 - How to replace picture & photograph
Owner's Manual 27 ENGLISH 1 . Turn off power and then open the upper part of front panel. 2 . Pull out the both links of lower part of front panel, as described in the below picture. 3 . Push and close the top part of the front panel and then pull the bottom part of the panel forward until it is sec...
Page 28 - Outdoor Unit; Common Problems and Solutions; Before calling for service
28 Room Air Conditioner Maintenance and Service (Side) (Rear) Air outlet �vents Air intake �vents Piping Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam...
Page 29 - Troubleshooting; The air conditioner may be operating abnormally when:; Problem
Owner's Manual 29 ENGLISH Maintenance and Service Troubleshooting The air conditioner may be operating abnormally when: Problem n The air conditioner isunplugged. n The fuse is blown/circuitbreaker is tripped. n Power failure. n Airflow is restricted. n The thermostat may not beset high enough. n Th...