ThinkServer TD200x Types 3719, 3821, 3822, and 3823 Installation and User Guide
Contents Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . . 1 Notices and statements in this document . . . . . . . . . . . . . . . . 2Related documentation . . . . . . . . . . . . . . . . . . . . . . 3 Chapter 2. Se...
Removing a hot-swap power supply . . . . . . . . . . . . . . . . . 63Installing a hot-swap power supply . . . . . . . . . . . . . . . . . 64 Installing redundant power supply and fans . . . . . . . . . . . . . . 66 Removing a voltage regulator module . . . . . . . . . . . . . . . . 68 Installing a v...
Installation order . . . . . . . . . . . . . . . . . . . . . . . 123Installing Windows 2003 components on the Core Server . . . . . . . . 124Installing Windows 2008 32-bit components . . . . . . . . . . . . . 124Uninstalling the LANDesk Software Agent . . . . . . . . . . . . . 125 Chapter 7. Trouble...
Avis de conformité à la réglementation d’Industrie Canada . . . . . . . 187Australia and New Zealand Class A statement . . . . . . . . . . . . 187United Kingdom telecommunications safety requirement . . . . . . . . 187European Union EMC Directive conformance statement . . . . . . . . 187Germany Clas...
Safety Before installing this product, read the Safety Information. Antes de instalar este produto, leia as Informações de Segurança. Pred instalací tohoto produktu si prectete prírucku bezpecnostních instrukcí. Læs sikkerhedsforskrifterne, før du installerer dette produkt. Lees voordat u dit produc...
Antes de instalar este producto, lea la información de seguridad. Läs säkerhetsinformationen innan du installerar den här produkten. Important: Each caution and danger statement in this document is labeled with a number. Thisnumber is used to cross reference an English-language caution or dangerstat...
Statement 1: DANGER Electrical current from power, telephone, and communication cables ishazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation,maintenance, or reconfiguration of this product during an electricalstorm. v Connect all power cords to a pro...
Statement 3: CAUTION:When laser products (such as CD-ROMs, DVD drives, fiber optic devices, ortransmitters) are installed, note the following: v Do not remove the covers. Removing the covers of the laser product couldresult in exposure to hazardous laser radiation. There are no serviceableparts insi...
Statement 4: ≥ 18 kg (39.7 lb.) ≥ 32 kg (70.5 lb.) ≥ 55 kg (121.2 lb.) CAUTION:Use safe practices when lifting. Statement 5: CAUTION:The power control button on the device and the power switch on the powersupply do not turn off the electrical current supplied to the device. The devicealso might have...
Statement 8: CAUTION:Never remove the cover on a power supply or any part that has the followinglabel attached. Hazardous voltage, current, and energy levels are present inside anycomponent that has this label attached. There are no serviceable parts insidethese components. If you suspect a problem ...
DANGER Overloading a branch circuit is potentially a fire hazard and a shock hazardunder certain conditions. To avoid these hazards, ensure that your systemelectrical requirements do not exceed branch circuit protectionrequirements. Refer to the information that is provided with your device forelect...
Chapter 1. Introduction This Installation and User Guide is intended to use with your Lenovo ® ThinkServer ™ TD200x (Machine Types 3719, 3821, 3822, and 3823) server. This documentcontains information about: v Setting up and cabling the server v Starting and configuring the server v Installing optio...
1 Model and machine type Important: The server keys cannot be duplicated by a locksmith. If you lose them, order replacement keys from the key manufacturer. The key serial number and thetelephone number of the manufacturer are on a tag that is attached to the keys. For a list of supported optional d...
v Danger: These statements indicate situations that can be potentially lethal or extremely hazardous to you. A danger statement is placed just before thedescription of a potentially lethal or extremely hazardous procedure step orsituation. Related documentation The Lenovo ThinkServer Documentation D...
Chapter 2. Server setup roadmap The installation process varies depending on the configuration of the server when itwas delivered. In some cases, the server is fully configured and just needs to beconnected to power and the network and started. In other cases, the server needsto have hardware featur...
Chapter 3. What is included with your server The TD200x server package includes the server, printed instructions, the ThinkServer Documentation DVD, and software media. 1 Server 2 Power cords, documentation, and software media Features and technologies The TD200x server offers the following features...
– Remotely accessing the server, using the keyboard and mouse from a remote client – Mapping the CD or DVD drive, diskette drive, and USB flash drive on a remote client, and mapping ISO and diskette image files as virtual drives thatare available for use by the server – Uploading a diskette image to...
Note: As of the date of this document, the Linux operating system does not support TOE. Specifications The following information is a summary of the features and specifications of theserver. Depending on the server model, some features might not be available, orsome specifications might not apply. 1...
Table 2. Features and specifications Microprocessor: v Intel Xeon dual-core or quad-core withintegrated memory controller and Quick PathInterconnect (QPI) architecture v Designed for LGA 1366 socket v Scalable up to four cores v 32 KB instruction cache, 32 KB data cache,and 8 MB cache that is shared...
EasyStartup The ThinkServer EasyStartup program simplifies the process of your RAIDcontroller and installing supported Microsoft ® Windows ® and Linux operating systems and device drivers on your server. The EasyStartup program is providedwith your server on DVD. The DVD is self starting (bootable)....
Chapter 4. Server controls, LEDs, and power This section describes the controls and light-emitting diodes (LEDs) and how to turnthe server on and off. Front view The following illustration shows the controls and LEDs on the front of the server. Note: The front bezel door is not shown so that the dri...
Power-control button: Press this button to turn the server on and off manually. A power-control-button shield comes with the server. You can install this disk-shapedshield to prevent the server from being turned off accidentally. Hard-disk drive activity LED: When this LED is flashing, it indicates ...
1 System power-on LED 2 Hard disk drive activity LED 3 System-locator LED 4 System-information LED 5 System-error LED v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the Hardware Maintenance Manual to determine which compone...
Rear view The following illustration shows the connectors and LEDs on the rear of the server. 1 USB 1 7 Power-error LED 2 USB 2 8 dc-power LED 3 USB 3 9 ac-power LED 4 USB 4 10 Video connector 5 Ethernet 10/100/1000 11 Serial 1 (COM 1) 6 Power-cord connector 12 Systems-management connector USB 1-4 c...
ac-power LED: Each hot-swap power supply has an ac-power LED and a dc-power LED. When the ac-power LED is lit, it indicates that sufficient power is coming intothe power supply through the power cord. During typical operation, both the ac anddc-power LEDs are lit. For any other combination of LEDs, ...
System-board external connectors The following illustration shows the external input/output connectors and the NMIbutton on the system board. 1 Video port 2 Serial port 3 10/100m RJ45 LAN connector 4 NMI button 5 USB ports 6 GbE RJ45 LAN connectors System-board switches and jumpers The following ill...
SAS backplane connectors The following illustration shows the connectors on the SAS backplane. 1 Hard disk drive connectors 2 Power connector 3 Signal connector 4 Configuration connector Power-supply LEDs The following illustration shows the power-supply LEDs on the rear of the server.For more infor...
provide cooling while the server is connected to power. You can turn on the serverand start the operating system by pressing the power-control button. The server can also be turned on in any of the following ways: v If a power failure occurs while the server is turned on, the server will restartauto...
Chapter 5. Installing optional devices and replacing customerreplaceable units This chapter provides detailed instructions for installing optional hardware devices inthe server. Installation guidelines Before you install optional devices, read the following information: v Read the safety information...
devices. However, you must turn off the server before performing any steps thatinvolve removing or installing adapter cables or non-hot-swap optional devices orcomponents. v Blue on a component indicates touch points, where you can grip the componentto remove it from or install it in the server, ope...
v Avoid wearing loose-fitting clothing on your forearms. Button long-sleeved shirtsbefore working inside the server; do not wear cuff links while you are workinginside the server. v Do not allow your necktie or scarf to hang inside the server. v Remove jewelry, such as bracelets, necklaces, rings, a...
Server components The following illustration shows the major components in the server. 1 Cover 14 USB cable/EasyLED diagnosticsassembly 2 Rear adapter retention bracket 15 DVD drive 3 Air baffle 16 Bezel 4 Heat sink 17 Optical drive bay EMC shield 5 Microprocessor 18 2.5-inch EMC shield 6 Heat sink ...
Opening the bezel Important: Before you install optional hardware, make sure that the server is working correctly. If an operating system is installed, start the server, and makesure that the operating system starts. If no operating system is installed, start theserver and make sure that a 19990305 ...
4. From inside of the top section of the bezel door, slide the blue tab up to unlock the bezel media door; then, grasp the depressed area on the left side of themedia door and pull the door open. 1 Bezel media door 2 Media door lock Note: To remove the media door from the bezel, push upward on the m...
Removing the bezel 1 Bezel 2 Hinge assembly 3 Retention tabs To remove the bezel, do the following: 1. Read the safety information that begins on page vii and “Handling static-sensitive devices” on page 39. 2. Unlock the left-side side cover. Note: You must unlock the side cover to remove the bezel....
Installing the bezel 1 Bezel 2 Hinge assembly 3 Retention tabs To install the bezel, do the following: 1. Align the hinge assemblies with the hinge holes on the chassis. 2. Push the hinges into the holes on the chassis until they snap into place. 3. If however, the bezel was removed by detaching the...
b. Align the sliding hinge mount 1 with the hinge pin 2 on the hinge assembly 3 on the chassis. c. Press the sliding hinge mount against the hinge pin until the sliding hinge mount snaps onto the hinge pin. 4. Close the bezel (see “Closing the bezel” on page 98). 5. Lock the left-side cover. Opening...
Closing the power-supply cage To return the power-supply cage to its closed position, do the following: 1. Rotate the power-supply cage back slightly; then, push the release tab on the rear power-supply support bracket out of the way. 1 Power supply support bracket 2 Power supply release tab Attenti...
4. Install and lock the left-side cover (see “Completing the installation” on page 97). 5. Install the hot-swap power supplies. 6. Reconnect the external cables and power cords; then, turn on the attached devices and turn on the server. Turning the stabilizing feet To rotate the front feet, do the f...
3. Reinstall the feet 1 in the opposite location. The tab on the feet should extend beyond the edge of the server. Internal cable routing and connectors You can install either an USB or a SATA tape drive in the server. The followingillustration shows the internal cable routing and connectors for bot...
Removing the air baffle To remove the air baffle, do the following: 1. Read the safety information that begins on page vii and “Installation guidelines” on page 37. 2. Turn off the server and all attached devices. 3. Disconnect all external cables and power cords. 4. Remove the left-side cover. 5. R...
Installing the air baffle To install the air baffle, do the following: 1. With the rear (hinged) part of the air baffle 3 lifted up, align the positioning pins on the ends of the air baffle with the locating holes in the server chassisand fan-cage assembly. 2. Slide the air baffle down into the serv...
Removing the fan-cage assembly 1 Fan cage assembly 2 Fan cage assembly release buttons To remove the fan-cage assembly, do the following: 1. Read the safety information that begins on page vii and “Handling static-sensitive devices” on page 39. 2. Turn off the server and peripheral devices, and disc...
Installing the fan-cage assembly 1 Fan cage assembly 2 Fan cage assembly release buttons To install the fan-cage assembly, do the following: 1. Align the guides on the fan cage with release latches on each side. 2. Push the fan-cage assembly into the server until it clicks into place. 3. If you remo...
6. Locate the battery on the system board (see “System-board internal connectors” on page 25). 7. Remove the battery: a. Use one finger to push the battery horizontally out of its socket, pushing it away from the socket. b. Lift and remove the battery from the socket. 8. Dispose of the battery as re...
To install the replacement battery, do the following: 1. Follow any special handling and installation instructions that come with the replacement battery. 2. Insert the replacement battery 1 : a. Hold the battery in a vertical orientation so that the smaller side is facing the socket. b. Place the b...
To remove a hot-swap power supply, do the following: 1. Read the safety information “Safety” on page vii and “Handling static-sensitive devices” on page 39. Attention: Static electricity that is released to internal server components when the server is powered on might cause the server to halt, whic...
5. Connect one end of the power cord for the new power supply into the connector on the back of the power supply; then, connect the other end of the power cordto a properly grounded electrical outlet. Note: If the server has been turned off, you must wait approximately 3 minutes after you connect th...
Removing a voltage regulator module 1 Microprocessor 2 VRM 2 Heat sink 2 3 VRM connector To remove a voltage regulator module (VRM), do the following: 1. Read the safety information (“Safety” on page vii) and “Handling static-sensitive devices” on page 39. 2. Turn off the server and peripheral devic...
Installing a voltage regulator module 1 Microprocessor 2 VRM 2 Heat sink 2 3 VRM connector To install a voltage regulator module, do the following: 1. Locate the VRM connector on the system board, next to the heat sink for microprocessor 2 (see “System-board internal connectors” on page 25). 2. Open...
Removing the rear adapter retention bracket 1 Rear adapter retention bracket 2 Hinge pin To remove the rear adapter-retention bracket, do the following: 1. Read the safety information that begins on page vii and “Handling static-sensitive devices” on page 39. 2. Turn off the server and all attached ...
Installing the rear adapter retention bracket 1 Rear adapter retention bracket 2 Hinge pins To install the rear adapter retention bracket, do the following: 1. Insert the bottom hinge point on the rear adapter retention bracket into the matching hole in the chassis; then, insert the top hinge point ...
Removing an adapter 1 Rear adapter retention bracket 2 Adapter 3 Front adapter retention bracket To remove an adapter, do the following: 1. Read the safety information that begins on page vii and “Handling static-sensitive devices” on page 39. 2. Turn off the server and peripheral devices, and disco...
v Locate the documentation that comes with the adapter and follow thoseinstructions in addition to the instructions in this section. If you must change theswitch or jumper settings on the adapter, follow the instructions that come withthe adapter. v Avoid touching the components and gold-edge connec...
Attention: Incomplete insertion might cause damage to the system board or the adapter. 8. Connect any needed cables to the adapter. If you have other devices to install or remove, do so now. Otherwise, go to“Completing the installation” on page 97. Removing the DVD drive To remove the DVD drive 1 , ...
Removing an optional tape drive 1 EMC shield 2 Tape drive To remove an optional tape drive, do the following: 1. Read the safety information that begins on page vii and “Handling static-sensitive devices” on page 39. 2. Turn off the server and peripheral devices, and disconnect the power cords and a...
Installing a USB or SATA tape drive The server supports USB and SATA tape drives. When you install a tape drive, besure to connect the internal tape cable to the correct connector on the systemboard. To install a tape drive, do the following: 1. Read the safety information that begins on page vii an...
6. Close the bezel (see “Closing the bezel” on page 98). Removing a memory module 1 DIMM 2 Retaining clip To remove a dual inline memory module (DIMM), do the following: 1. Read the safety information that begins on page vii and “Handling static-sensitive devices” on page 39. 2. Turn off the server ...
Installing a memory module The following notes describe the types of dual inline memory modules (DIMMs) thatyour server supports and other information that you must consider when you installDIMMs. 1 Microprocessor 1 2 Microprocessor 2 v The server supports industry-standard double-data-rate 3 (DDR3)...
v The server supports 1 GB, 2 GB, and 4 GB DIMMs, with a minimum of 1 GB anda maximum of 64 GB of system memory. For 32-bit operating systems only: Some memory is reserved for various system resources and is unavailable to the operating system. The amount ofmemory that is reserved for system resourc...
1 DIMM 2 Retaining clip 10. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector. Firmly press the DIMM straight downinto the connector by applying pressure on both ends of the DIMMsimultaneously. The retaining clips snap into the lock...
d. Slide the rear flange of the heat sink into the opening in the retainer bracket. e. Press down firmly on the front of the heat sink until it is seated securely. f. Rotate the heat-sink release lever to the closed position and hook it underneath the lock tab. 13. Install a VRM in the connector by ...
1 Microprocessor 2 0.02 mL of thermal grease 5. Use the thermal-grease syringe to place nine uniformly spaced dots of 0.02 mL each on the top of the microprocessor. Note: 0.01 mL is one tick mark on the syringe. If the grease is properly applied, approximately half (0.22 mL) of the grease will remai...
4. Pull outward on the free end of the handle to remove the fan from the server. 5. If you are instructed to return the hot-swap fan, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you. Installing a hot-swap fan The server comes with three 120 mm...
4. Rotate the top edge of left-side cover toward the server; then, press down on the cover handle until it clicks into place (“Installing the side cover” on page 99). 5. Rotate the bezel to its fully closed position. 6. Using the supplied key, lock the left-side cover and bezel. 7. Connect the cable...
1 Pull point To close the bezel, do the following: 1. Rotate the left side of the bezel toward the server to the closed position. 2. Lock the left-side cover, using the key that comes with the server. Installing the side cover 1 Cover release latch 2 Lock 3 Left-side cover To install the left-side c...
1 USB 1 7 Power-error LED 2 USB 2 8 dc-power LED 3 USB 3 9 ac-power LED 4 USB 4 10 Video 5 Ethernet 10/100/1000 11 Serial 1 (COM 1) 6 Power cord connector 12 Systems management Updating the server configuration When you start the server for the first time after you add or remove a device, youmight r...
Table 9. Server configurations and applications for configuring and managing RAIDarrays (continued) Server configuration RAID array configuration(before operating system isinstalled) RAID array management(after operating system isinstalled) ServeRAID-MR10i SAS/SATAController (LSI 1078)installed Mega...
v User Security Select this choice to set, change, or clear passwords. See “Passwords” for moreinformation. This choice is on the full and limited Setup Utility menu. – Set Power-on Password Select this choice to set or change a power-on password. For moreinformation, see “Power-on password” on page...
v Change the position of the power-on password switch (enable switch 2 of thesystem board switch block (SW6)) to bypass the power-on password check (seethe following illustration). 1 UEFI boot recovery jumper (JP6) 2 Clear CMOS jumper (JP1) 3 SW6 switch block Attention: Before you change any switch ...
Using the Boot Selection Menu program The Boot Selection Menu is used to temporarily redefine the first startup devicewithout changing boot options or settings in the Setup Utility. To use the Boot Selection Menu program, do the following: 1. Turn off the server. 2. Restart the server. 3. Press F12 ...
Table 10. RAID utilities (continued) RAID configurationutility Description Location Where to find moreinformation LSI Logic MPT SetupUtility For: v ServeRAID-BR10icontroller v ServeRAID-BR10iecontroller In system firmware.To access: v Use UEFI SetupUtility. v Press Ctrl + C atthe LSI promptduring st...
8. Exit the Setup Utility. Using the WebBIOS utility The WebBIOS configuration utility enables you to create and manage RAIDconfigurations on LSI SAS controllers. The WebBIOS utility resides in the SAScontroller BIOS and operates independently of the operating system. The WebBIOSutility provides a c...
Using the ThinkServer EasyStartup DVD The ThinkServer EasyStartup DVD simplifies the process of configuring your RAID controller and installing an operating system. The program works in conjunction withyour Windows or Linux operating-system installation disc to automate the processof installing the ...
v Manually remove the drives that you do not want included in your arraybefore you configure your RAID controller through the EasyStartupprogram. This method enables you to use the EasyStartup program to configure your RAIDcontroller and install the operating system. After the operating system is in...
If you continue to the main program interface, you will have the following selectableoptions: v Compatibility notes: This selection provides information about the operating systems and server configurations supported by that version of the EasyStartupprogram. v User Guide: This selection provides in...
v Power/Reset control (power-on, hard and soft shut down, hard and soft reset,schedule power control) v Alerts (in-band and out-of-band alerting, PET traps - IPMI style, SNMP, e-mail) v Operating system failure blue screen capture v Command line interface v Configuration save and restore v PCI confi...
Use the command-line interface to issue setup commands. You can save any of thesettings as a file and run the file as a script. The ASU program supports scriptingenvironments through a batch-processing mode. Installing ThinkServer EasyManage software You can install the ThinkServer EasyManage Core S...
4. Select the checkbox next to Web Server (IIS) . A dialog box displays the additional features that are required. 5. Click Add Required Features , then click Next . In the list of additional role services that can be installed, ensure that the follow are checked: v HTTP Redirection v Static Content...
DVD drive problems v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field repla...
Hard disk drive problems v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field...
Memory problems v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replacea...
Microprocessor problems v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field ...
Monitor problems Some monitors have their own self-tests. If you suspect a problem with yourmonitor, see the documentation that comes with the monitor for instructions fortesting and adjusting the monitor. v Follow the suggested actions in the order in which they are listed in the Action column unti...
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs)...
Power problems v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceab...
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replaceable units (FRUs)...
Software problems v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the parts listing in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRUs) and which components are field replac...
2. Check for loose cables in the power subsystem. Also check for short circuits, for example, if a loose screw is causing a short circuit on a circuit board. 3. Remove the adapters and disconnect the cables and power cords to all internal and external devices until the server is at the minimum confi...
4. Click Downloads and drivers to download firmware updates. If IPMItool is installed in the server, you can use it to view the system-event log.Most recent versions of the Linux operating system come with a current version ofIPMItool. You can view the IMM event log through the Event Log link in the...
POST error codes When you turn on the server, it performs a series of tests to check the operation ofthe server components and some optional devices in the server. This series of testsis called the power-on self-test, or POST. If a power-on password is set, you must type the password and press Enter...
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the "Parts Listing" section in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replace...
v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved. v See the "Parts Listing" section in the Hardware Maintenance Manual to determine which components are customer replaceable units (CRU) and which components are field replace...
Note: After you exit from the stand-alone memory diagnostic environment, you must restart the server to access the stand-alone memory diagnosticenvironment again. 5. Select gui to display the graphical user interface, or select cmd to display the DSA interactive menu. 6. Follow the instructions on t...
To save the DSA log to a file on a diskette or to the hard disk, click Save Log on the diagnostic programs screen and specify a location and name for the saved logfile. Notes: 1. To create and use a diskette, you must add an optional external diskette drive to the server. 2. To save the test log to ...
Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more informationabout Lenovo products, you will find a wide variety of sources available fromLenovo to assist you. This section contains information about where to go foradditional infor...
Calling for service During the warranty period, you can get help and information by telephone throughthe Customer Support Center. These services are available during the warranty period: v Problem determination - Trained personnel are available to assist you with determining a hardware problem and d...
Service methods and procedures vary by country, and some services might not beavailable in all countries. International Warranty Service is delivered through themethod of service (such as depot, carry-in, or on-site service) that is provided in theservicing country. Service centers in certain countr...
estimated through extrapolation. Actual results may vary. Users of this documentshould verify the applicable data for their specific environment. Trademarks The following terms are trademarks of Lenovo in the United States, other countries,or both: LenovoLenovo logoThinkServer The following terms ar...
Lenovo makes no representation or warranties regarding non-Lenovo products andservices, including but not limited to the implied warranties of merchantability andfitness for a particular purpose. These products are offered and warranted solely bythird parties. Some software might differ from its ret...
L’etiquette du système respecte la Directive européenne 2002/96/EC en matière deDéchets des Equipements Electriques et Electroniques (DEEE), qui détermine lesdispositions de retour et de recyclage applicables aux systèmes utilisés à traversl’Union européenne. Conformément à la directive, ladite étiq...
Battery return program This product may contain a lithium or lithium ion battery. Consult your user manualor service manual for specific battery information. The battery must be recycled ordisposed of properly. Recycling facilities may not be available in your area. Forinformation on disposal or bat...
This device complies with Part 15 of the FCC Rules. Operation is subject to thefollowing two conditions: (1) this device may not cause harmful interference, and (2)this device must accept any interference received, including interference that maycause undesired operation. Industry Canada Class A emi...
Lenovo Manuals
-
Lenovo 04N7323
User Manual
-
Lenovo 04N7323
Manual
-
Lenovo 04W1420
Manual
-
Lenovo 04N7324
User Manual
-
Lenovo 04N7324
Manual
-
Lenovo 04W3947
Manual
-
Lenovo 04W3948
Manual
-
Lenovo 04X2623
User Manual
-
Lenovo 04W3949
Manual
-
Lenovo 0A33942
User Manual
-
Lenovo 0A33942
Manual
-
Lenovo 06P3799
User Manual
-
Lenovo 06P3799
Manual
-
Lenovo 0B47184
User Manual
-
Lenovo 0B47190
User Manual
-
Lenovo 0B47190
Manual
-
Lenovo 0B39663
User Manual
-
Lenovo 0B39663
Manual
-
Lenovo 0C52685
User Manual
-
Lenovo 0C52865
User Manual