Page 2 - Application; stages on it’s own internal controls; Installation; Remove the cover. Replace the cover when; Features; CAUTION; Slots; WARNING

Page 2 Application • Two zones• Single-stage electric or gas furnace• Single-stage air conditioner• Multi-stage equipment can be used provided that it stages on it’s own internal controls • Not applicable to heat pump systems Installation • Install the control panel indoors only. • Do not install th...

Page 3 - FIGURE 3 – DISCHARGE AIR SENSOR LOCATION; FRONT; Figure 3

Page 3 Installation (continued) FIGURE 3 – DISCHARGE AIR SENSOR LOCATION 15" D/3 W D FRONT IMPORTANT: The discharge air sensor is required. If a short or open circuit is detected between thePlenum Sensor terminals, the control panel will onlyrespond to Zone 1 and the dampers will stay in theopen...

Page 5 - Bypass Damper Sizing; ). The barometric damper and the bypass duct

Page 5 Bypass Damper Sizing When fewer than the maximum number of zones arecalling for heating or cooling, an excess volume of air isdelivered, and because of the excess air, an excessamount of static pressure is produced as well. Zonesystems often require a bypass duct to relieve thispressure. A pr...