Page 3 - .0 GENERAL INFORMATION; Fireplace; APPLIANCE SPECIFICATIONS; Table 1
3 .0 GENERAL INFORMATION This appliance is a high efficiency, unvented, flame effect gas heater. It provides radiant and convected warmth both efficiently and safely utilizing the latest type catalytic convertor burner technology. The appliance does not require a flue system of any type as the catal...
Page 4 - UNPACKING THE APPLIANCE; Page; Massachusetts Requirements
4 6.0 BURN-IN PERIOD On initial light up of a new appliance, the ‘newness’ will burn off within the first few hours of operation. During this period some smoke may be emitted from outlet grill, this should be no cause for concern. Accord- ingly, the room should be well ventilated with all windows an...
Page 5 - COMBUSTION AND VENTILATION AIR; WARNING; Air for Combustion
5 8.0 COMBUSTION AND VENTILATION AIR This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air. The heater may be located in unusually tight construction provided the space is unconfined, or if co...
Page 6 - Gas connection: The heater gas inlet connection is 3/8” NPT at the; Figure 1 - Gas Supply Entry Points; CLEARANCES TO NON-COMBUSTIBLES; CAUTION; The back of the appliance may be installed directly; NOTE: See Page 19 for gas
6 9.0 SITE REQUIREMENTS This appliance is designed to be wall-hung. Do not recess any part of the appliance into the wall. This appliance may be installed in any room in a home except bathrooms - or areas where large amounts of steam are likely to be generated. This appliance is approved for install...
Page 7 - Figure 2; PREPARING THE APPLIANCE; IMPORTANT NOTE: All gas piping must be done by a
7 Non-concealed gas connections may be made using the entry points at either end of the firebox or the one in the bottom of the firebox. A concealed gas connection may be made using the knock out hole in the center back of the firebox. Select the most appropriate entry point and knock out the releva...
Page 8 - MOUNTING THE APPLIANCE; The wall where the appliance is to be installed must; THIS APPLIANCE MUST BE SECURED DIRECTLY TO THE STUDS AT THE; that may occur due to improper installation or handling.
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE After having selected the final mounting position of the appliance, taking into account the site requirements as specified in these instructions, the integrity of the wall, and the feasibility of the proposed supply pipe routing, the firebox of a...
Page 9 - Figure 4; FITTING THE SURROUND ASSEMBLY; Due to the weight of the frame assembly, it is recommended to seek; Figure 5; Heat Shield
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 9 It is recommended that the burner height, where possible, should be approximately 4 ft. from the floor. This will give the best viewing position. When selecting the height, ensure that the clearance to the ceiling is 3" minimum, as specified ...
Page 10 - CHECKING THE BURNER; Figure 6; tank may cause an explosion.; IMPORTANT; Hold heater regulator with a wrench to prevent move-; CHECKING THE GAS CONNECTIONS; C. When the gas lines are tested and leak free, be sure to rinse off the; GAS PRESSURE CHECK; Never use an open flame to check for leaks.; Checking Manifold Pressure at Provided Test Point (see; Table 1
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 14.0 CHECKING THE BURNER There are no imitation fuel bed components, such as logs or rocks, to install. The appliance features a ribbon burner which is designed to produce a continuous band of flame over its length. The burner should be visually...
Page 11 - Pressure Setting; BRIEFING THE CUSTOMER; Do not add logs or ornaments such as pine cones,
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 11 Figure 7a Burner (Manifold) Pressure Figure 7b - Manifold and Inlet Pressure Taps Regulator (Inlet) Pressure Setting If the pressure is too high, the gas supply meter may be set incorrectly. This should be checked with the appliance running and ...
Page 13 - Do not block the catalysts or the appliance outlet grill.; converters reach very high temperatures (up to 700° F). Measuring; .0 TESTING FOR FIREBOX LEAKAGE; Do not operate the appliance with the catalyst units; Figure 9 - Catalysts and Outlet Grill; DO NOT BLOCK
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 13 1.0 CATALYSTS WARNING Do not block the catalysts or the appliance outlet grill. Blockage may cause high carbon monoxide levels and/or breakage of the glass door assembly. It is recommended that the catalysts are inspected for signs of damage and...
Page 14 - FOR YOUR SAFETY READ BEFORE LIGHTING; TO TURN OFF GAS TO APPLIANCE; ‘OFF’ position
14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a pilot which must be lit with a piezo ...
Page 15 - be the problem and removal of the draft should resolve this.
15 4.0 TROUBLESHOOTING GUIDE PROBLEM CORRECTIVE ACTION Igniter sparks but pilot does not light • No gas to Pilot, check the gas line connections. • Air not fully purged. Purge supply or wait longer. • Spark grounding to metal work, reset gap correctly. • Blocked pilot, clean out internally. Pilot li...
Page 16 - Hardware; See ordering instructions on; Replacement Parts
16 5.0 REPLACEMENT PARTS - X-FIRES-1000 5 4 15 Hardware NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 12 1 2 5 6 7 8 10 11 13 14 See ordering instructions on Page 20 WARNING CLEARANCES FROM COMBUSTIBLE MATERIALS F860041/A The following clearances must be maintained at all times.Failure to do s...
Page 17 - POSITIONING OF FIELD REMOVABLE PARTS; Failure to position the parts in; off burner; screws indicated, then
17 6.0 POSITIONING OF FIELD REMOVABLE PARTS WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi- cally approved with this heater may result in property damage or personal injury. Figure 13 4 off burner installation positions Figure 12 Glass Do...
Page 18 - Limestone Surround; Surround Specifications; Product Reference Information; character with no two pieces being quite the same.
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE 7.0 SPECIFICATIONS X-FIRE-1000 Surround Kits Cat. No. Model Description Ship. Wt. Ship. Volume H76 X-FIRE-1000-L Limestone Surround 55 lb. 4.58 cu. ft. H77 X-FIRE-1000-G Granite Surround 55 lb. 4.58 cu. ft. 39-7/16” 11-1/4” 25-1/4” 21-3/16” 15-3...
Page 19 - REGULATOR GAS ENTRY POINT
19 Note: The actual dimensions are shown in millimeters. The fractional dimensions are converted from millimeters and are rounded to the nearest 1/16”. KEY:D1 = Distance from mounting surface to rear entry pointD = Distance from mounting surface to center of side entry pointD3 = Distance from mounti...
Page 20 - WARRANTY; warranty to be familiar with its coverage.; See; The installation date of the appliance.; Natural Gas; PRODUCT REFERENCE INFORMATION
Printed in U.S.A. © 007 Lennox Hearth Products P/N 50603-01 REV. C 05/009 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for firepl...