Page 2 - TABLE OF CONTENTS; USING THIS MANUAL
2 CONGRATULATIONS! When you purchased your new gas stove, you joined the ranks of thousands of individuals whose answer to their home heat-ing needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjo...
Page 5 - COLOCACIóN DE ADVERTENCIAS DE; LENNOX HEARTH PRODUCTS; WARNINGS; LENNOX HEARTH PRODUCTS; Figure A
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer. Une étiquette de sécurité doit être collée sur la p...
Page 6 - THE GAS STOVE
6 • Must conform with all local, state and national installation codes. In the absence of local codes, the installation must conform with National Fuel Gas Code ANSI Z223.1 latest edition, also known as NFPA 54 (In Canada, the current CAN/CSA B149.1 installation code). Refer to the National Fuel G...
Page 7 - Canadian; COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS; Massachusetts Horizontal Vent Requirements
7 Installation of these appliances are approved for installation in New York City in the US state of New York (MEA#: 13807E). CODES AND APPROVALS Certification Gas appliances must be tested and certified by a nationally recognized testing and certification laboratory to ANSI (American National Sta...
Page 8 - * Other approved chimney brand is Simpson DuraVent DVGS.; RATINGS; Maximum heat output BTUs/hour-steady state; Page
8 * Other approved chimney brand is Simpson DuraVent DVGS. PRE-INSTALLATION RATINGS VISN-35 / SDVSS-35 VISN-25 / SDVSS-25 NATURAL GAS LP GAS NATURAL GAS LP GAS Max/Min Input BTUh 0-2,000 Feet (0-610 M ) u 35,000/23,000 35,000/23,500 25,000/17,500 25,000/18,000 Manifold Pressure (IN. WC) 3.5 10.0 3...
Page 9 - Rear Vent Dimensions; Dimensions; and may create a serious fire, health, or other safety hazard.; Top View; Figure 1; Flue Collar
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 14-7/8” (378mm) 18-1/2” (470mm) 32-1/2” (826mm) Rear Vent Dimensions Dimensions The gas line attaches to the gas valve at the back of the stove 21/2” in from the left side of the stove and 81/2” up from the base of the unit. Test all gas conne...
Page 10 - Pipe Clearances; for allowable pipe configurations.; Leg on Combustible; Clearances to Combustibles; Corner Installation; Alcove dimensions; Alcove Dimensions; Figure 4; Parallel Installation
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Pipe Clearances All installations using a vertical termination cap must maintain one inch clearance between the directvent pipe and combustibles. For horizontal runs of pipe, one inch of clearance to combustibles on the sides and bottom and tw...
Page 12 - * Fifty percent or less of ember material (rockwool) supplied should; the log should face the front.; Figure 8
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 7. Place the left log on burner supports with the charred surface facing up. The left log will only fit on the burner supports in one direction. 8. Place embers around the perimeter of the burner and sparingly in field of burner. Do not block a...
Page 14 - Vent Parts List; Part Number; Horizontal Vent Installation
14 Vent Parts List Secure Vent™ directvent pipe by Security Chimneys™* may be used with this appliance. Please see the lists below to verify the components available from each directvent pipe manufacturer. Snorkel terminations are available for applications which may require vertical rise on the ...
Page 15 - Flame Color and Behavior
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Storm Collar Vertical Termination Cap Ceiling Firestop Framing 10”x 10” Roof - Maintain 1” Clearance to Combustibles Pipe Length Flashing Hand break to remove unwanted restrictor Light Obstru...
Page 16 - Horizontal Terminations; One 45° elbow is allowed when venting horizontal, straight off; COMBINATION OF VERTICAL AND HORIZONTAL LENGTHS CANNOT EXCEED 25’.; Straight Horizontal With No Vertical; for snorkel; Vertical Terminations; Venting configurations; Vision 25 standard cap; See note
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Horizontal Terminations The shaded areas in the diagram below show all allowable combinations of vent configurations with horizontal terminations. Horizontal sections of pipe require 1/4” of rise for every 12” of run. A second 90 degree or 45 d...
Page 17 - Exterior Horizontal Vent Termination Clearance Requirements; Minimum Clearances
17 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Exterior Horizontal Vent Termination Clearance Requirements V V V V V F C B B A B H M I X V D V A A A V L B J X E V A G *18” 18” B C C C K X * See Item D in the Text Below. Center Line of Termination Exterior Wall Horizontal Termination Ventila...
Page 18 - Gas Control Knob; The appliance must be isolated from the gas supply piping system
18 Gas Line Installation This stove must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the current CAN/CSA B149.1 installation code). The gas line screws into the gas valve at the back of the stove 21/2” in from the left side ...
Page 19 - APPOSITION DES MISES EN GARDE; COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. INSTALLER INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe opera...
Page 21 - IMPORTANT NOTE: When opening the lower door while; SIT Millivolt Gas Valve; Burner Flame Appearance
21 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 10. After pilot is lit, turn gas control knob counterclockwise .2 to “ON.” Knob can only be turned to “ON” if the knob has popped out. 11. To turn burner on, turn “ON/OFF” rocker switch to “ON” or set the thermostat to the desired temperature a...
Page 22 - Shutter Adjustment Handle; Turn the handle to the left to open and to the right to close.
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 25 Air Shutter Adjustment CAUTION: Air shutter is hot while the appliance is operating and should only be adjusted using a heat resistant glove. The air shutter control lever is located on the bottom of the stove directly to the left of ...
Page 24 - WARNING; Turn off gas and electrical power to the fireplace
24 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. CAUTION: Wear gloves and safety glasses for protection while doing required maintenance. Verify proper operation after servicing. S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé. CAUTION: Label all wires prior to d...
Page 25 - CAUTION
25 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Glass Door Only doors certified with the appliance shall be used. Seules des portes certifiées pour cet appareil doivent être utilisées. CAUTION: DO NOT abuse glass door by striking or slamming shut. Do not remove glass door while the appliance...
Page 28 - POWER CORD; RING LUG CRIMP
28 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Wire Harness Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débr...
Page 29 - in poor performance and safety hazards.
29 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. AVERTISSEMENT Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces...
Page 30 - NOTE: The form numbers referenced are the part numbers of the
30 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Trim Kits (ref. form #775290M) Kits Include: Matching Trim for Glass, Louvers and Ash Lip Cat. No. Model Description 75276 VISN-TRIM-B-G Black Trim/Gold Handle 75277 VISN-TRIM-B-N Black Trim/Nickel Handle 75274 VISN-TRIM-G-G Gold Trim/Gold Hand...
Page 31 - HOT WHILE IN OPERATION. DO NOT TOUCH. SEVERE BURNS MAY RESULT. KEEP; DATE OF MANUFACTURE / DATE DE FABRICATION; CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE
31 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. ALCOVE DIMENSIONS - DIMENSIONS – ALCOVE MAXIMUM DEPTH / PROFONDEUR MAXIMUM 35”(889mm) MINIMUM WIDTH / LARGEUR MAXIMUM 51”(1295mm) MINIMUM HEIGHT / HAUTEUR MAXIMUM 46”(1168mm) SEE OWNER’S MANUAL FOR OTHER ALCOVE CLEARANCE CONFIGURATIONS. RÉFÉREZ...
Page 33 - NOTES
Page 34 - Natural Gas; WARRANTY
34 Printed in U.S.A. © 2007 Lennox Hearth Products P/N 775222M REV. F 09/2011 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fi...