Page 2 - TABLE OF CONTENTS; USING THIS MANUAL
2 CONGRATULATIONS! When you purchased your new gas fireplace insert, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefi...
Page 5 - ). Choisissez la langue qui est principale; COLOCACIóN DE ADVERTENCIAS DE; ) o en el termostato de pared; LENNOX HEARTH PRODUCTS; WARNINGS; ). The warnings should already have been; LENNOX HEARTH PRODUCTS; Figure A
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer...
Page 6 - Fireplace Requirements; WARNING; THIS FIREPLACE HAS BEEN ALTERED TO
6 For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice should be derated by 4% for every 1,000 feet to maintain the proper ratio of gas to air. Improper orifice sizing may result in damage and unsafe conditions. Changing the orifice should only be done by a quali fied service te...
Page 7 - Certification
7 (Massachusetts Approval #G3-1104-102) These appliances are approved for installation in the US state of Mas sachusetts if the following additional requirements are met: • Install this appliance in accordance with Massachusetts Rules and Regulations 248 C.M.R. Sec. 5.08 2(a) through 2(e). • Instal...
Page 9 - Insert Dimensions; Width of insert behind Surround Panels; CAUTIONS; RTV high temperature silicone is an approved; Figure 1; Minimum Fireplace Opening; * Top air duct will need to be removed for short ZC applications.
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Insert Dimensions Minimum Fireplace Cavity 31-1/4” (794mm) 13-3/4” (349mm) 15-3/4" (400mm) 19-3/4 (502mm) 15-3/4" (400mm) 19-1/2" (495mm) Top View Side View Insert Dimensions Width of insert behind Surround Panels 31-1/4" (794mm)...
Page 10 - The letters below, E through J, correspond to; Hearth Protection; Figure 4A; the RDV40/SDVI40 mantel clearances as shown in; Figures 4A; and; Facing and
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Note: Hearth protection to be min. 3/8” (10mm) thick non-combustible or equivalent, with a k factor of .84. Insert Leveling At each front and rear corner of the insert is an adjustable leg provided to level the insert should the hearth of the f...
Page 11 - Venting Installation; current edition of the National Fuel Gas Code ANSIZ223.1 (In Canada,; Direct-Vent Fireplace Insert Vent Requirements - Use liner; Vent Kits; INSTALLATION; Masonry and Factory Built Fireplaces; Figure 6a - Terminating Air Inlet in Chimney; Vertical Venting; Figure 6b
11 Note: The minimum vertical rise (exhaust vent) is 10 feet (3.1 M) and the maximum vertical rise is 35 feet (10.7 M). These dimensions are measured from the starting collars of the unit to the end of the vent pipe.The fireplace and fireplace chimney must be clean and in good working order and cons...
Page 12 - Zero Clearance Fireplace Installation; Note; Brick Panel and Log Set Installation; Retainer; RACK AND THE BURNER PAN.; Side Brick Panels; Figure 7; Screws
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Zero Clearance Fireplace Installation This appliance may be installed in a masonry or factory built/zero clear ance (ZC) fireplace. When installing in a ZC fireplace, the ZC grate must be removed and the ZC damper must be removed or secured op...
Page 13 - Face Installation; NEVER use brass polish to clean plated surfaces, this; Surround Installation; Packaging List; ) from the parts bag and install; Spring Handle Latches
13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 4. Install a light layer of rockwool directly over the ports. A light layer will give a more constant rear flame. A heavy layer will give more glow, but will need to be adjusted after light up. 5. Install front logs on retainer slots. Face ...
Page 14 - Robertshaw Millivolt Gas Valve; Pressure Tap
14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Gas Line Installation After leveling, position the insert in the fireplace holding it about six inches out from its final location. CAUTION: Specific hearth requirements apply (see Clearances to Combustibles). This appliance must be connected...
Page 16 - ). To properly complete the installation of this; APPOSITION DES MISES EN GARDE; ) ou sur le thermostat; COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD; ) y en el transmisor
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. INSTALLER INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe opera...
Page 18 - TO TURN OFF GAS TO APPLIANCE; PILOT ASSEMBLY; IMPORTANT NOTE: When opening the lower door on the face
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNINGS • Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information, consult a qualified installer, service agency or your gas supplier. • Operation of t...
Page 19 - Flame Color and Behavior; Figure; Burner Flame Appearance; Paint Curing
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Flame Color and Behavior This appliance is designed for maximum heating efficiency. Therefore, upon lighting of the main burner the flames will be semitransparent or “bluish.” After 1020 minutes of operation the logs will heat up and the flam...
Page 20 - Thermostat Wire; Millivolt Control Schematic
20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Operating Options The rocker switch on your gas appliance is used to turn the burner on and off while the pilot is on. The rocker switch can be installed in the hole in the right side of the top surround panel or in the hole in the panel to the...
Page 21 - Turn off gas and electrical power to the fireplace; The viewing glass should be cleaned periodically (see Glass Main-
21 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. CAUTION: Wear gloves and safety glasses for protection while doing required maintenance. Verify proper operation after servicing. S'assurer que l'appareil fonctionne adéquatement une fois l'entretien terminé. Maintenance Checklist The following...
Page 22 - CAUTION
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Glass Door Removal To remove the glass door, pull forward and up on the top latches. Lift the glass door up and off the lower spring latch. Be careful not to damage or scratch the glass while handling. To reinstall the glass, reverse the remova...
Page 23 - qualified service technician should perform the conversion.
23 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Electrical Requirements: This gas appliance operates without an outside power source, however the blower requires a 120 Volt electrical service outlet. This appliance, when installed, must be electrically grounded in accordance with local codes...
Page 25 - Description; in poor performance and safety hazards.
25 Cat. No. Description H3132 Cassette Assembly NG 33,000 BTU (if LP, also requires H5433 Conversion Kit) H3045 Cassette Assembly NG 40,000 BTU (if LP, also requires H5433 Conversion Kit) H6010 Burner Assembly H5922 Pilot Assembly Convertible, NG or LP H5938 Gas Control Valve NG (if LP, also require...
Page 27 - complete face
27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Surround Panel Kits (ref. form #775261M) 75362 RDV-DBV-FP2941-B1 29" x 41" BLACK Trim (One-piece) 75068 RDV-DBV-FP2941-B 29" x 41" BLACK Trim 75069 RDV-DBV-FP2948-B 29" x 48" BLACK Trim 75070 RDV-DBV-FP3341-B 33" x 4...
Page 30 - WARRANTY; Natural Gas
Printed in U.S.A. © 2007 Lennox Hearth Products P/N 775218M REV. E 09/2011 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for firep...