Page 2 - TABLE OF CONTENTS; USING THIS MANUAL
2 CONGRATULATIONS! When you purchased your new wood stove, you joined the ranks of thousands of individuals whose answer to their home heating needs reflects their concern for aesthetics, efficiency and our environment. We extend our continued support to help you achieve the maximum benefit and enjo...
Page 3 - READ THIS MANUAL IN ITS ENTIRETY AND UNDER-; DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY
3 1. When this room heater is not properly installed, a house fire may result. To reduce the risk of fire, follow the instal- lation instructions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. 2. Wear gloves during installation to ...
Page 4 - A draft test should; TESTING INFORMATION; Overfiring Damage; DRAFT REqUIREMENTS; Figure 1; - Chimney Height Requirements; Less than; Page 5; Chimney Height Requirements
4 This manual describes the installation and operation of these non-catalytic wood heaters. These heaters meet the U.S. Environmental Protection Agency’s emissions limits for wood heaters sold on or after July 1, 1990. This heater has been developed, tested and constructed in accordance with the req...
Page 6 - Venting System on; has never been installed because a knock-out will be in place
6 WARNING: BE ABSOLUTELY SURE THE DISTANCE BETWEEN THE HEATER AND THE SURFACE OF ANY COMBUSTIBLE CONSTRUC- TION IS NOT LESS THAN SHOWN IN THE FIGURES ON PAGE 7. Floor Protection USA - The floor in front and under the heater must be protected with noncombustible material. The covering must extend 16”...
Page 7 - G G; Installation; INSTALLATION CLEARANCES - REFER TO FIGURES 2, 3 ANd 4
7 Diagram B: Side View-Alcove & Parallel Installation Diagram A: Top View-Parallel Installation K B A E C D *L K Floor Protection Floor Protection Floor Protection G G F F 72" Min. H I M J I J H † E † E L 48” Maximum Depth Diagram C: Top View-Corner Installation N P T PIPE INSTALLATION A B (...
Page 8 - Single Wall Pipe; Using 6” Diameter Single Wall Connector Pipe; Figure 5 - Typical Installation; YOUR CHIMNEY INSTALLATION MUST COMPLY WITH LOCAL
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Shown with Tubinox™ Stainless Steel Liner components (see Page 28 for ordering information) Chimney Termination Cap Chimney Termination Rain Cap Masonry Adaptor Length 90° Tee Storm Collar Roof Flashing Flashing Ceiling Support Assembly Slip Ada...
Page 9 - Figure 7; Using 6” Diameter Type L-Vent Connector Pipe; Figure 7 - Typical Installation
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Manufactured Home Installations (ref. Figure 7 ) This appliance is approved for installation into a manufactured (mobile) home in the USA ONLY! Installation should be in accordance with the Mobile Home Construction and Safety Standard, Title 24 ...
Page 10 - Figure 8; thicknesses shall be permitted.
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Chimney Connector Systems and Clearances from Combustible Walls for Residential Heating Appliances (NFPA 211) Refer to Figure 8 System A. Minimum 3.5 in. (90 mm) thick brick masonry wall framed into combustible wall with a minimum of 12 in. (30...
Page 11 - Note: The threaded rods used to bolt the legs to the stove are pack-; Residential and Mobile Homes; Figure 9; LEG AND HEATSHIELD INSTALLATION; Washer
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 10 Figure 9 To install the “Outside Air Kit,” position the clip so that the nut is directly above the hole punched in the back of the heatshield (See Figure 11 ). Install the outside air adapter box on the stove by sliding it into the ai...
Page 12 - Pages; YOUR CHIMNEY INSTALLATION MUST; Insert the allen
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 14. All horizontal runs of pipe should be as short as possible and are required by NFPA No. 211 to have an upward pitch or rise in the same direction the smoke travels of no less than 1/4” to the linear foot. The connector pipe must meet minimu...
Page 15 - Brick Sizes; side rear baffle on the top side of the front baffle.; Baffle Insulation Parts
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Brick Sizes A = 4-1/4” x 9” B = 2-1/4” x 8-7/8” D = 2-1/4” x 9” E = 1-1/2” x 8-7/8” F = Full Brick (4-1/2” x 9”) G = 1-1/2” x 9” Figure 14 3. Next, you will install the baffle blanket. It will be installed with the 11” dimension from the front ...
Page 16 - ted; Do; OK; CAUTION; Be careful not to abuse door assembly by striking or; DO NOT
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Be sure to clean plated accessories with a household type cleaner and a very soft cloth to remove any fingerprints and residues prior to the first fire. 1. NEVER USE FLAMMABLE LIqUIDS TO START OR REKINDLE A SOLID FUEL FIRE!! 2. Fully open the p...
Page 17 - WARNINGS; Figure 18 - Blower Wiring Schematic; Blower Operation Guidelines; NOTE: Turn blower off before opening the door to load the fuel.; BLOWER OPERATION; Figure 19 - Blower Controls; Blower Speed Control; Blower Operation
17 WARNINGS The blower must be plugged directly into a properly grounded three-prong receptacle, 120 VAC, 60 Hz, single phase. Do not cut or remove the grounding prong from this plug. Do not route power cord under or in front of appliance.Installation must be in accordance with National Elec- trical...
Page 19 - WARNING; MAINTENANCE; TIPS FOR KEEPING THE GLASS CLEAN
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. DOOR HINGES: If door hinges need lubricating, use an anti-seize com- pound (never use oil) available from your Lennox Hearth Products dealer. DOOR LATCH: If your door latch fails to latch tightly and the gasket is in good condition, place a len...
Page 20 - SMOKES WHEN; TROUBLESHOOTING
20 Problem Solution POOR DRAFT: Extend chimney in length or have the chimney realigned to the proper size flue. Oversized chimneys normally have poor drafts. Remember, the stoves’ draft depend solely on the natural draft of the chimney (See Draft Requirements on Page 4 ). If your stove is not drafti...
Page 21 - Check the chimney and baffle monthly to make sure they are clean.; DO; DO’S AND DON’TS
21 DO NOT: Install or operate this stove before reading this manual. DO NOT: Close the draft beyond the point at which the flames are completely extinguished. DO NOT: Open the stove door without fully opening the draft first. DO NOT: Burn driftwood or wood that has been in salt water. This includes ...
Page 23 - REPLACEMENT PARTS - MODELS S160 AND SWS160
23 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. REPLACEMENT PARTS - MODELS S160 AND SWS160
Page 24 - Door Parts
24 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. REPLACEMENT PARTS - MODELS S160 AND SWS160 Door Parts Blower Parts 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 25 29 31 28 27 26 32 30
Page 25 - Leg and Leg Parts
25 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. REPLACEMENT PARTS - MODELS S160 AND SWS160 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 22 24 18 20 21 23 Leg and Leg Parts
Page 26 - Ash Drawer Pedestal and Pedestal
26 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. REPLACEMENT PARTS - MODELS S160 AND SWS160 15 18 15 18 19 16 17 19 Ash Drawer Pedestal and Pedestal
Page 28 - Security ChimneysTM Pipe; Tubinox Components
28 ACCESSORIES - MODELS S160 AND SWS160 Secure Black™ Single Wall Stove Pipe 6” SW Pipe and Accessories Cat. No. Model Description Pc. / Container 6SWL6 6SWL6 LENGTH 6” X 6” 100 6SWL12 6SWL12 LENGTH 6” X 12” 5 6SWL24 6SWL24 LENGTH 6” X 24” 10 6SWL36 6SWL36 LENGTH 6” X 36” 2 6SWL48 6SWL48 LENGTH 6” X...
Page 29 - Secure Temp® Factory-Built Chimney
29 ACCESSORIES - MODELS S160 AND SWS160 Secure Temp® Factory-Built Chimney 6” Secure Temp ASHT and Secure Temp G-ASHT Cat. No. Model Description Pc. / Container Lengths and Fittings 6L8 6L8 LENGTH 6” X 8” 1 6L12 6L12 LENGTH 6” X 12” 1 6L18 6L18 LENGTH 6” X 18” 1 6L24 6L24 LENGTH 6” X 24” 1 6L36 6L36...
Page 32 - LENNOX HEARTH PRODUCTS; PRODUCT REFERENCE INFORMATION
32 Your Appliance’s Model Number _______________________________________ Your Appliance’s Serial Number ________________________________________ The Date On Which Your Appliance Was Installed __________________________ Your Dealer's Name _________________________________________________ WARRANTY You...