Page 2 - To order a FREE Lennox; Operation Warnings; All parts of your Lennox; Pay special attention to all warnings and safety information.; TABLE OF CONTENTS; FREE; SAFETY; OFFER; The Lennox; To receive your FREE; Note: Safety Guards may not be available for some
2 Safety and Your Fireplace To prevent severe burns and injuries, install a screen or physical barrier to prevent direct contact with the glass . To order a FREE Lennox ® SAFETY GUARD for your fireplace, see details at left. Follow the safety instructions below and be sure everyone in your house...
Page 3 - Toutes les parties de votre foyer; SAFETY GUARD GRATIS; ¡Todas las partes de la chimenea; Seguridad y
3 Afin d'éviter de vous brûler gravement ou de vous blesser, installez une grille ou une barrière physique pour empêcher tout contact direct avec la vitre . Pour commander un PANNEAU DE PROTECTION Lennox ® GRATUIT pour votre foyer, consultez les détails dans la partie gauche. Suivez les instruct...
Page 5 - Figure A; Figure B; APPOSITION DES MISES EN GARDE RELATIVES; COLOCACIóN DE ADVERTENCIAS DE; LENNOX HEARTH PRODUCTS; WARNINGS; LENNOX HEARTH PRODUCTS
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE . Figure A Figure B APPOSITION DES MISES EN GARDE RELATIVES À LA SÉCURITÉ D’UTILISATION Votre foyer a été livré avec des étiquettes de sécurité qui doivent être collées à côté des dispositifs de contrôle du foyer . Une étiquette de sécurité doit ...
Page 7 - General Information; Please read and carefully follow all of
7 General Information Please read and carefully follow all of the instructions found in this manual . Please pay special attention to the safety instructions provided in this manual . PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE FOR YOUR SAFETY do not install or oper- ate this appliance without first...
Page 8 - Canadian
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Installation of these appliances are approved for installation in New York City in the US state of New York (MEA#: 138-07-E) . NEW YORK CITY, NEW YORK (MEA) COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS (Massachusetts Approval #G3-0806-6) These app...
Page 9 - RATINGS; NATURAL GAS
9 PRE-INSTALLATION Features Installation Options .25 Residential .25 Vented vertical and horizontal .25 Manufactured (mobile) home .25 Natural gas (NG) or propane (LP) .25 Bedrooms .25 Optional wall-mounted thermostat Venting This fireplace can be vented using Secure Vent™ direct-vent pipe by Securi...
Page 10 - Dimensions; Minimum clearances to combustible materials in inches:; Figure 1; Mantel and Facing; Fireplace side view
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. u The center of the access hole for the gas piping is located at the left side of the fireplace 6-1/4” back from the front edge and 2-1/8” up from the base of the unit. v The electrical access is located at the right lower rear of the fire- pla...
Page 11 - Framing Dimensions; The fireplace may be placed directly on wood or non-combustible; Framing Suggestions:; The framing header above the front of the; Hearth Extension Considerations; for further details .; Corner Installations:; The dimensions on this page are minimum and; Figure 3; INSTALLATION
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Framing Dimensions The dimensions given on this page are minimum framing distances necessary to maintain safe clearances between the Ravelle™ 30 gas fireplace and combustible materials . u If the unit is to be vented horizontally with a 90º elb...
Page 12 - Figure 5; RavelleTM 30 Fireplace Dimensions
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 40.59 1.39 20.94 21.97 28.05 14.05 40.95 5.01 11.45 40.59 3.92 20.38 9.63 3.57 5.45 7.90 22” (558mm) 40-9/16” (1031mm) 5” (127mm) 14-1/16” (357mm) 3-15/16” (100mm) 40-15/16” (1040mm) 11-7/16” (291mm) 28-1/16” (713mm) 9-5/8” (245mm) 3-9/16” (91m...
Page 13 - for hearth; Base of Fireplace; Figure 7
13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Raised Installations The fireplace may be raised by building a platform of sufficient strength to support the fireplace and pipe . When building a raised hearth extension, please see the note below regarding height of the fireplace in relation ...
Page 14 - If the combined thickness of the facing; Facing Installation Considerations; Figure 9
14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. The screws should be driven through the cement board into the outer metal skin of the fireplace . The sheetrock (drywall) is then butted up to the cement board . The sheetrock above the fireplace should also be fastened to the fireplace by driv...
Page 15 - for installing the templates are included with the templates .; Classic Inset; Adjustment prior to arched face installation:; Template; Reveal Corner; Expanded View of Reveal Corner; Reveal Corner Adjusted
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Facing Greater Than 1” (25mm) Thick: If the combined thickness of the facing material (eg . brick or cultured stone) and cement board is greater than 1”, then the facing material must be placed around the face . A template (see kit part numbers...
Page 16 - . Bracket C in the lower diagram is installed on the face during the; Face Installation; Expanded View
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 2 . Bracket C in the lower diagram is installed on the face during the face assembly (see instructions included with face) . The captive screws D on this bracket should be screwed into captive nuts E on the fireplace . A phillips head screw dri...
Page 18 - Vent Considerations
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 15 Vent Considerations Twist-lock procedure: Four indentations, located on the female ends of pipes and fittings, are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so...
Page 19 - Elbow
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Horizontal Vent Installation IMPORTANT NOTES: 1. All Ravelle™ 30 gas fireplaces that are horizontally terminated may only use 6-5/8” x 4” direct-vent pipe by Security Chimneys™ or Dura-Vent ® . 2. When this pipe passes through a wall, a wall th...
Page 20 - Vertical Vent Termination Clearances
20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. IMPORTANT NOTES: 1. All Ravelle™ 30 fireplace vertically terminated may only use 6-5/8” x 4” Secure Vent™ direct-vent pipe by Security Chimneys™ or GS direct-vent pipe by Dura-Vent ® . 2. If the vent passes through a ceiling or floor, a firesto...
Page 21 - Flue Restrictors; Flue Restrictor Guidelines; Flue Restrictor Adjustment Guidelines; Flame Color and Behavior; Restrictors; Symptoms - Lack of Combustion Air
21 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Flue Restrictors The flue restrictor settings shown in Figures 20 and 21 are for typical installations and may need to be adjusted from standard to take into account other variables in the installation to achieve proper combustion. See Flue Res...
Page 22 - Horizontal Terminations
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Vertical Terminations The diagram to the below shows all allowable combinations of straight vertical and offset to vertical vent configurations with vertical terminations . The termination must fall within the shaded areas on the diagram . Use ...
Page 23 - Exterior Horizontal Vent Termination Clearance Requirements; Minimum Clearances
23 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Exterior Horizontal Vent Termination Clearance Requirements V V V V V F C B B A B H M I X V D V A A A V L B J X E V A G *18” 18” B C C C K X * See Item D in the Text Below. Center Line of Termination Exterior Wall Horizontal Termination Ventila...
Page 24 - Log Installation Instructions; combustion, sooting and poor flame quality.; Brick Panel; Figures; BRICK PANEL AND LOG SET INSTALLATION; Firebox Accessories / Parts; Log Set and Embers
24 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 24 Figure 25 Figure 26 Log Installation Instructions If logs are not installed according to the log installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon...
Page 26 - Robertshaw Millivolt Gas Valve; Pressure Tap
26 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Fuel Type Inlet Pressure Manifold Pressure Desired Minimum Maximum On Hi Fire On Lo Fire Natural Gas 7" WC 5" WC 10.5" WC 3.5" WC 1.7" WC LP Gas 11" WC 10.5" WC 13" WC 10" WC 5.4” WC The Ravelle™ 30 gas firep...
Page 27 - Whole Home Comfort System:; Starter Ring; Maximum Run; INCREASING EFFICIENCY AND HOT AIR MOVEMENT
27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. A number of different options are available to the homeowner to maximize the heat output and air movement to different rooms in the house . Grills: If your Ravelle™ 30 gas fireplace is installed in a cabinet or a chase, heat can be drawn from t...
Page 28 - APPOSITION DES MISES EN GARDE; COLOCACIóN DE ADVERTENCIAS DE SEGURIDAD
28 INSTALLER INSTRUCTIONS - ATTACHING SAFETY-IN-OPERATION WARNINGS It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appliance. SAFETY LABEL DIAGRAMS DIAGRAM...
Page 29 - Pre-Lighting Checklist
29 Operating Instructions Pre-Lighting Checklist Be sure to check these items before the initial lighting of the fireplace: c The fireplace gas label corresponds to the gas supply avail- able - that is "natural gas" for natural gas or "LP gas" for LP gas . c Gas pressure has been che...
Page 30 - PILOT ASSEMBLY
30 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 10 . After pilot is lit, turn gas control knob counterclockwise .2 to "ON ." Knob can only be turned to "ON" if the knob has popped out . 11 . To turn burner on, turn "ON/OFF" rocker switch to "ON" or set the the...
Page 31 - Burner Flame Appearance
31 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Flame Color and Behavior Your Ravelle™ 30 gas fireplace is designed for maximum heating ef-ficiency . Therefore, upon lighting of the main burner the flames will be semi-transparent or “bluish .” After 10-20 minutes of operation the logs will h...
Page 32 - Blower Operation; Your Ravelle 30 gas fireplace comes equipped with a 155 CFM blower; Optional Wall Thermostat; Do not mount the thermostat where it may be affected by:; Paint Curing
32 Blower Operation Your Ravelle 30 gas fireplace comes equipped with a 155 CFM blower with a variable speed control and an automatic temperature activated on/off snap switch . Operation: 1 . After the fireplace warms up, a heat activated switch will turn on the blower . A blower speed control is lo...
Page 34 - WARNING; Turn off gas and electrical power to the fireplace
34 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Vent Pipe Maintenance Conduct an inspection of the venting system semi-annually . Recom- mended areas to inspect are as follows: 1 . Check areas of the venting system which are exposed to the elements for corrosion . These will appear as rust s...
Page 35 - doors; CAUTION; Door Latch
35 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Glass/Door Maintenance Cleaning: When cool, the glass may be cleaned with a clean, soft cloth and a household glass cleaner . For cleaning white condensation from the interior glass use a gas fireplace glass cleaner available from your fireplac...
Page 37 - in poor performance and safety hazards.
37 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. AVERTISSEMENT Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à ces...
Page 38 - complete face; ACCESSORIES
38 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Brick Panel Kits (ref. form #775268M) Cat. No. Model Description H7982 RAVL30-STD-BRK Standard Tan Brick 75360 RAVL30-RED-BRK Red Brick Misc . 75259 NP-RAVL30/42 Nail Plates (4x12) galvanized Remote Thermostat is not compatible with R30. Contac...
Page 40 - DE SERVICE OU UN FOURNISSEUR DE GAZ.; SAFETY / LISTING LABELS
40 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. RATINGS NG LP NG LP Input Rate on “HI” (BTU/H) 30,000 28,500 Minimum Inlet Pressure (in. WC) 5 11 Input Rate on “LO” (BTU/H) 20,000 20,000 Manifold Pressure on “HI” (in. WC) 3.5 11 Orifice Size (DMS)* #37 #51 Manifold Pressure on “LO” (in. WC) ...
Page 41 - FOR YOUR SAFETY READ BEFORE LIGHTING; property damage, personal injury or loss of life.; LIGHTING INSTRUCTIONS; LIGHTING LABEL - ENGLISH
41 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by a pie...
Page 42 - LIGHTING LABEL - FRENCH; POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER; Situé dans l’âtre sur la même surface que le dessus du
42 REMARQUE : LES SCHÉMAS ET LES ILLUSTRATIONS NE SONT PAS À L’ÉCHELLE LIGHTING LABEL - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER INSTRUCTIONS D’ALLUMAGE COMMENT COUPER L’ADMISSION DE GAZ DE L’APPAREIL 4. Enfoncez légèrement le bouton de réglage du gaz et tournez-le dans le . ” F F O “ t ê ...
Page 43 - NOTES
43 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. NOTES
Page 44 - Natural Gas; PRODUCT REFERENCE INFORMATION
44 Your Fireplace’s Model Number ________________________________________Your Fireplace’s Serial Number ________________________________________The Date On Which Your Fireplace Was Installed ___________________________The Type of Gas Your Fireplace Uses ____________________________________Your Deale...