Page 2 - TABLE OF CONTENTS; Please read and understand these; kit will Not be used by every model.; INTRODUCTION; Use Only These Approved Vent Components; GENERAL INFORMATION; DO NOT ATTEMPT TO ALTER OR MODIFY; WARNING
2 WARNING B-Vent appliances are not designed to operate in negatively pressured environments (pres- sure within the home is less than pressures outside). Significant negatively pressured environ- ments caused by weather, home design, or other devices may impact the operation of these appliances. Neg...
Page 3 - 0 - latest edition, or the Canadian Electrical; Table 1
3 WARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING Failure to comply with these installation i...
Page 4 - Figure; - Honeywell Electronic Gas Valve; Flame Height; Table 5; Table; SIT Millivolt Gas Valve; REQUIREMENTS FOR THE COMMON-; Tables 3 and 4; Table 3
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Gas Valve Diagrams See Figure 1 for Millivolt models and Figure 2 For Electronic Models. Figure 2 - Honeywell Electronic Gas Valve FF O NI P S I N O L O RT N O C GI N TIER Manifold Pressure Port ON / OFF Switch Inlet Pressure Port Electronic Gas...
Page 5 - Figure 3 - Typical Installations; must not extend beyond the front edge of the unit.; Do not insulate the space between the appli-
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 5 COLD CLIMATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room. It is especially important to insulate outside chase cavity between studs and ...
Page 6 - Termination Heights For Vents
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. VENT TERMINATION CLEARANCES Gas Vent Rule - Gas vent caps are not per- mitted within 8 feet (2.4 mm) of a vertical wall or similar obstruction. Gas vent caps that are located 8' or more from a portion of a building which extends at an angle grea...
Page 7 - When the unit is installed with one; In addition, when the unit is; Figure 5 - Minimum Mantel Clearances; Top Of Appliance; NOTE - The side walls of mantels; Table 6; Mantel Depth; Figure 6 - Minimum Distance to Unprotected Side Wall
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 7 MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances Maintain clearances from appliance to combustible materials as detailed in Table 6 with the following exception: When the unit is installed with one side flush with a wall, the wal...
Page 8 - TYPICAL INSTALLATION SEQUENCE; Figure 7; Figure 8; DETAILED INSTALLATION STEPS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 8 Turn nailing tabs down and secure to the floor with 8d nails or other appropriate fasteners on both sides of appliance. * NOTE: INSTALLATION DIAGRAMS AND INSTRUCTIONS SHOW THE FRONT OF THE APPLIANCE AS THE SIDE WHICH HAS VALVE ACCESS, EXCEPT WHE...
Page 9 - FIREPLACE SPECIFICATIONS - MPB35ST; SPECIFICATIONS; Framing Specifications; PRODUCT REFERENCE INFORMATION; Model; EFFICIENCIES; Figure 9; • Minimum Framing Stud Size is 2 x 4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 9 FIREPLACE SPECIFICATIONS - MPB35ST SPECIFICATIONS Natural Gas BTU Input 30,000 Propane Gas BTU Input 28,000 B-Vent Size 5 in. (127 mm) NOTES Due to Lennox' ongoing commitment to quality, all specifications, ratings and dimensions are subject to ...
Page 10 - Step 2. ROUTING GAS LINE; Table 7; Proper Sizing of Gas Line; Figure 10 - Route Gas Line
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 10 Notes: • All appliances are factory-equipped with a flexible gas line connector and 1/2 inch shutoff valve (see Figure 19 on Page 14 ). • See Massachusetts Requirements on Page 4 for additional requirements for installations in the state of Mas...
Page 11 - CAUTION; This appliance cannot be vented; Approved Vent Components
60 Degrees Maximum 12 Feet (3.7 Meters) Minimum 11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 1" (25 mm) Minimum Firestop Note: Refer to the vent manufacturers instal- lation instructions for variations of venting techniques. If common venting of several units is contemplated, it shoul...
Page 12 - Spill Switch; Millivolt Wiring Diagram; Note: Supply wires may be alternatively con-; Verify proper operation after servicing.
Figure 14 Thermopile TH TP TH TP White White Black Spill Switch If any of the original wire as supplied must be replaced, it must be replaced with Type AWM105 C - 18 gage wire. * Optional Kits - OFF/ON wall switch or remote control receiver. Millivolt Wiring Diagram Appliance mounted OFF / ON Switch...
Page 13 - Step 5. CONNECTING GAS LINE; Valve Access Side; WIRING; ) to a point within the; Never use an open flame to
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 13 Step 5. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply line. The orientation of the shut-off valve should face the front. Figure 19 illustrates two methods for connecting the gas supply. A Sediment Trap is recommen...
Page 14 - CONTROL COMPARTMENT ACCESS INSTRUCTIONS (; Step 6. OUTSIDE AIR KITS; on; Gas; GAS CONNECTION
CONTROL COMPARTMENT ACCESS INSTRUCTIONS ( Ref. Figure 20 ) Opening Control Compartment Door: Gently depress the outer top corners of the louvered Control Compartment Access Panel until the spring-loaded magnetic catches "pop" it free, allowing it to swing out and down to open. Removing Contr...
Page 15 - GLOWING EMBERS AND LOGS; Step 7. VERIFY APPLIANCE OPERATION; Page; Proper Pilot Flame Appearance; ELECTRONIC; Control Compartment Access Panel
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. The outside air shutter should be fully open when the fireplace is in use and completely closed when the fireplace is not being used. Closing it when not in use will prevent outside cold air from entering the dwelling.Operate the actuator throu...
Page 16 - LOG SET; LOG SET - IDENTIFICATION; REFERENCE; Top View of Logs; Glowing Embers; Bag of Glowing; Top View of Logs - Installed
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LOG SET Catalog Number H3210 * Item Description A Log, Center B Log, Left Rear C Log, Left Front D Log, Right Rear E Log, Top Center F Log, Front Center * Item "letters" above correspond to photos on right LOG SET - IDENTIFICATION REFER...
Page 17 - READ WARNINGS ON Page 15 BEFORE PROCEEDING; Removal Instructions,; Position The Groove in The Back of Log (C); Embers
17 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Position The Groove At The Bottom Of Log (A) Over The Grate And Slide It Forward Against The Grate Here Figure 27 READ WARNINGS ON Page 15 BEFORE PROCEEDING 1. Remove the front glass enclosure panel (see Glass Enclosure Panel Removal Instructio...
Page 18 - surface must be clean, free of irregularities and seated firmly.; • Handle this glass with extreme care! Glass is
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 18 E F (Valve Access Side) (Valve Access Side) Position The Round End Of Log (E) Against The Notch Of Log (D) Here. Two Charred Spots Face The Front D Position Small End of Log (E) on The Notch of Log (C) Here C Log (F) Sits in Front of The Grate ...
Page 19 - Burner Air Shutter Adjustment Procedure; Burner Flame Appearance; Step 10. BURNER ADJUSTMENTS
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNINGS • Air shutter adjustment should only be performed by a quali- fied professional service tech- nician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Soot will be produced if the air shutter is closed t...
Page 20 - See Page 5 for Cold Climate Insulation and; Remove Top Louvered
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 20 17 Combustible Wall Framing Combustible Finished Wall Materials Drywall Bracket/Spacer Top of Appliance Louvers Top of Door Frame Hood must be installed as shown. 1 in. Min. (25 mm) Top Spacers Top of Appliance Radiant panel Top of Door Frame H...
Page 21 - ) y en el transmisor de control; WARNINGS; ). The warnings should already have been; Figure A
21 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 13. ATTACHING SAFETY-IN-OPERATION WARNINGSIt is the installer ' s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this a...
Page 22 - Removing Control Compartment Door,; this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.; Electronic
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 22 Air Shutter Adjustment Lever Venturi Tube Arm Pan Burner Valve Access Side of Fireplace Firebox Subfloor Figure 38 In Canada: THE CONVERSION SHALL BE CAR- RIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDI...
Page 23 - All Models; Note: If the igniter is damaged, a replacement kit; Electronic Appliances; and replace the pilot orifice as fol-; Table 8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 23 Pressure Regulator Remove These Components P S I OFF I ON CONTROL IG N IT E Gas Valve Assembly Manifold Pressure Test Port Slotted Cap Spring Adjusting Screw Figure 42 Figure 41 Figure 43 Figure 40 Figure 39 Figure 44 All Models Step 7. (Refer ...