Page 2 - TAbLE OF CONTENTS; please read and understand these; pACKAGING LIST; GENERAL INFORmATION; WARNING
2 TAbLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Massachusetts and New York Requirements ................................ Page 4Cold Climate Insulation ..............
Page 3 - 0 - latest edition, or the Canadian Electrical; Table 1
3 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier...
Page 4 - Tables 3 and 4; REQUIREmENTS FOR THE COmmON-; NOTE: Flame appearance will diminish 4% per; Flame Height; SIT Millivolt Gas Valve; Figure 2; - Honeywell Electronic Gas Valve; Table 2; Table 5
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. manifold Gas Supply pressure (all models) Fuel # Low (millivolt only) High Natural Gas (Lo) 2.2" WC (0.55 kpa) (Hi) 3.5" WC (0.87 kpa) propane (Lo) 6.3" WC (1.57 kpa) (Hi) 10.0" WC (2.49 kpa) Table 4 Inlet Gas Supply pressure (al...
Page 5 - Figure 3 - Typical Installations; Note: When the unit is installed with one side flush; • An
5 Figure 3 - Typical Installations Note: When the unit is installed with one side flush with a wall, the wall on the other side of the unit must not extend beyond the front edge of the unit. COLd CLImATE INSULATION For cold climate installations, seal all cracks around your appliance with noncombust...
Page 6 - Termination Heights For Vents
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. VENT TERmINATION CLEARANCES Gas Vent Rule - Gas vent caps are not per- mitted within 8 feet (2.4 mm) of a vertical wall or similar obstruction. Gas vent caps that are located 8' or more from a portion of a building which extends at an angle grea...
Page 7 - Table 6; ” Clearance; Figure 6; *Note: See Figures 7 and 8 on Page 8 for clearance requirements to; mINImUm CLEARANCES TO COmbUSTIbLES; in Table 6 with the following exception:; When the unit is installed with; Figure 5 - Minimum Mantel Clearances; MANTEL CLEARANCES
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Hearth Extension - A hearth extension is not required with this appliance. If a hearth extension is used, do not block the control compartment access panel. Any hearth extension used is for appearance only and does not have to conform to standar...
Page 8 - Attach Safety in Operation; FRAmING; All framing details must allow for a minimum; dO NOT; dETAILEd INSTALLATION STEpS; TYpICAL INSTALLATION SEQUENCE; Figure 8; Side Nailing Flanges
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 7. (Page 15) Outside Air Kit Installa- tion. Step 8 . (Page 16) Verify appliance opera- tion. Step 9 . (Page 16) Install grate, vermiculite, embers and logs. Step 10 . (Page 21) Installation/Removal of glass enclosure panels. Step 11. (Page...
Page 9 - FRAmING SpECIFICATIONS; materials, calculations will need to be made.; Header; ti; mm; Figure 9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 9 FRAmING SpECIFICATIONS Note: All framing dimensions calculated for 1/2" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made. * Outside air kit - FOAK (without ...
Page 10 - FIREpLACE SpECIFICATIONS
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 10 F E B D C G Top View FRAMING SPACERS (Top and Sides and Rear) Front View 3 (76) A J H Flue Outlet For B-Vent Connection OPTIONAL ELECTRICAL INLET KNOCKOUT REQUIRING A FIELD PROVIDED JUNCTION BOX (Either Side) GAS INLET (Either Side and bottom) ...
Page 11 - ROUTE GAS SUppLY LINE; Figure 11 - Route Gas Line; Right Side Front; Table 7; proper Sizing of Gas Line
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 11 Step 2. ROUTE GAS SUppLY LINE Route a 1/2" (13 mm) gas line as shown in Figure 11. Gas lines must be routed, con- structed and made of materials that are in strict accordance with local codes and regulations. The appliance, as set up at the...
Page 12 - Note: Refer to the vent manufacturers instal-; CAUTION; This appliance cannot be vented; General Information; Approved Vent Components; on
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 13 Figure 12 Type b-Vent - 4 in. (102 mm) for mpb 3328 models, 5 in. (127 mm) for mpb 3530 / 4035 models or 6 in. (153 mm) for mpb 4540 models Securing Screws Flue Outlet Collar USE ONLY AppROVEd b-VENT dIAmETER mpb-3328, mpb-3530, mpb-4...
Page 13 - Figures 17 or; Verify proper operation after servicing.; Note: The electronic appliance must be con-; BLOWER CONTROL CIRCUIT WIRING; Junction Box Wiring
13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. A. SIT millivolt Wiring (See Figure 14) – 1 . Select any of the following optional controls: appliance-mounted (rocker switch) or wall- mounted switch, thermostat, or one of the optional remote control kits. If appliance- mounted ON/OFF control...
Page 14 - Showing the Blower Wiring for the Optional; Showing the blower Wiring for the Optional; Step 6. CONNECTING GAS LINE; 0 illustrates two methods for connecting the; AIR bLOWER KIT; Note: The tab connecting the receptacles of
14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 17 Figure 18 1. If any of the original wire as supplied must be replaced, 1. it must be replaced with Type AWM 105 ° C – 18 GA. wire. 2. 120V, 60Hz – Less than 3 amps. BK Junction Box Transf. 120 V. 24 V Factory Wired Field Wired BL Elec...
Page 15 - tive leak test solution but it is not recommended,; Step 7. OUTSIdE AIR KITS; Never use an open flame to
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Using pipe-dressing materials appropriate for the gas type, securely affix the shut-off valve to this determined pipe length at a convenient location outside of the appliance lower control compartment. TEST ALL CONNECTIONS FOR GAS LEAKS (FACTOR...
Page 16 - TION; Note: Instructions are also found on the litera-; Electronic Appliance Checkout; Shown with control; ELECTRONIC pILOT ASSEmbLY
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 16 Step 9. INSTALLING LOGS, dECORA- TIVE VOLCANIC STONE ANd GLOW- ING EmbERS Step 8. VERIFYING AppLIANCE OpERA- TION With gas line installed run initial system check- out before closing up the front of the unit. Follow the pilot lighting instructi...
Page 17 - Handle logs carefully to prevent; Glowing Embers, Vermiculite, decorative Volcanic Stone And Log; Note: This appliance is provided with enough Glowing Embers for; Glowing Embers; Bag of Glowing
17 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Proper twig placement is critical to prevent sooting. Twigs should be placed in the gaps between the flame peaks and should be positioned so that at no time they impinge the flames. 1. Remove the appliance front door. 2. Remove the log set from...
Page 21 - INSTALLING OR REMOVING GLASS dOOR; Note: When installing the glass door, ensure the
21 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Only doors certified with the appliance shall be used. Seules des portes certifiées pour cet appareil doivent être utilisées. CAUTION: dO NOT abuse glass door by striking or slamming shut. These appliances are designed to operate only with the ...
Page 22 - Step 11. bURNER AdJUSTmENTS; • If there is smoke or soot present, first check; WARNINGS; burner Air Shutter Adjustment
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 33 main burner Factory Air Shutter Opening Setting - Inches (millimeter) model Natural Gas propane Gas mpb-3328 Fully Closed 3/16" (4.76 mm) mpb-3530 Fully Closed 3/16" (4.76 mm) mpb-4035 Fully Closed 3/16" (4.76 mm) mpb-4540...
Page 23 - Step 12. VENT OpERATION TEST; - Close all doors and windows in the room.
23 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 36 burner Flame Appearance - model mpb-4035 & mpb-4540 Figure 34 Figure 35 burner Flame Appearance - model mpb-3328 burner Flame Appearance - model mpb-3530 Step 12. VENT OpERATION TEST After appliance installation, perform this vent...
Page 24 - Detail A; Limit; HOOd INSTALLATION; On louvered face units; FINISHING REQUIREmENTS; Wall Details; This area must remain clear; Detail B
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 24 Scoop Scoop Securing Screws Fire box Top Lintel Securing Screw Hole in Cabinet Top Figure 37 blocked Flue Safety Limit Location, Inside View of Firebox, Top/Right Side Intersection Detail A Detail C Fire box Top Limit Limit/bracket Securing Scr...
Page 25 - COLOCACIóN dE AdVERTENCIAS dE; LENNOX HEARTH pROdUCTS; LENNOX HEARTH pROdUCTS; Figure A
25 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 14. ATTACHING SAFETY IN OpERATION WARNINGS It is the installer ' s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this ...
Page 26 - GAS CONVERSION KITS; Millivolt; this installation assumes responsibility for this conversion.; AVERTISSEmENT; assume les responsabilités liées à la conversion.; CAUTION: THE GAS SUppLY SHALL bE; Figure 21. Access the control compartment.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 26 GAS CONVERSION KITS In Canada: THE CONVERSION SHALL bE CAR- RIEd OUT IN ACCORdANCE WITH THE REQUIREmENTS OF THE pROVINCIAL AUTHORITIES HAVING JURISdICTION ANd IN ACCORdANCE WITH THE RE- QUIREmENTS OF THE CAN/CSA-b149.1 INSTALLATION COdE. LA CON...
Page 27 - Table 8
27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 40 b. Refer to Figure 40 and remove the pilot hood assembly to access the hexed pilot orifice. Remove and replace the orifice with the one provided with the kit. pilot for SIT millivolt Gas Valve pilotOrifice Figure 42 All models Step 8....