Page 2 - TABLE OF CONTENTS; Massachusetts and New York; GENERAL INFORMATION; - one envelope containing the literature; PACKAGING; - one foam packaged log set located in fire-; Natural Propane; Please read and understand these
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Packaging ........................................ page 2 Introduction ..................................... page 2 Massachusetts and New York Requirements ................................ page 2 General Information ..................
Page 3 - LOCATION; Figure 1
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs ofcarbon monoxide poisoning are similar to theflu with headaches, dizziness and/or nausea. Ifyou have these signs, obtain fresh air immedi-ately. Turn off the gas supply to the applianceand have it serviced by ...
Page 4 - APPLIANCE SPECIFICATIONS; Front View
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Venting Gas Vent Rule – Gas vent caps are not permit-ted within 8 feet (2.4 mm) of a vertical wall orsimilar obstruction. Gas vent caps that arelocated 8' or more from a portion of a buildingwhich extends at an angle greater than 45 ° upward from th...
Page 5 - FRAMING SPECIFICATIONS; ASSEMBLY STEPS; Header
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. FRAMING SPECIFICATIONS Figure 4 Figure 5 Figure 6 Framing Dimensions ASSEMBLY STEPS The typical sequence of installation follows,however, each installation is unique resultingin variations to those described. 1. Construct the appliance framing. 2. R...
Page 6 - INSTALLING THE FIREPLACE; Consult all local codes.; Figure 8; d Nail or
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Step 3. Position the Appliance - Slide thefireplace into prepared framing or position fire-place in its final position and frame later. Refer to fireplace drawings and specificationson pages 4 and 5 for framing dimensions anddetails. Framing header ...
Page 7 - Minimum; Figure 16 on page 9.; MILIVOLT WIRING DIAGRAM; Flue Outlet
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 10 Step 4. Install the Vent System & ExteriorTermination - Slip a 10" (254 mm) B-Vent system over theappliance collar ( Figure 10 ) and secure with four sheetmetal screws (# 8 or larger).Minimum overall height of the vent systemand ap...
Page 8 - open when the; ELECTRONIC WIRING DIAGRAM
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 14 1. Route a 3-wire 120V 60Hz power supply lineto the appliance junction box wires and ground(Figures 13 ). 2. After wiring is complete, replace the appli-ance junction box cover and secure with the hexhead screws previously removed. Step 6....
Page 10 - of all sets are similar.; APPLIANCE OPERATION; Detail A; SIT Valve
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 17 Figure 18 Refer to the Homeowners Care and OperationInstructions for detailed log description andplacement instructions. Log set shown in thisdocument (Figure 17 ) is typical, installation of all sets are similar. APPLIANCE OPERATION Step...
Page 11 - Replace logs if removed for pilot inspection.; Natural
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 22 Adjustment To adjust the flame, position the air shutter tothe nominal setting (Figure 22 ). Allow the burner to operate for at least 30 minutes.Observe the flame continuously. If it appearsweak or sooty as previously described, adjustthe...
Page 14 - Gas Conversion Kits; In Canada
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 25 PressureRegulator RemoveTheseComponents Step 1. Turn off the gas supply to the appli-ance. Remove the front glass door (if used)from the appliance. Access the control com-partment. Step 2. Carefully remove the logs. Exercisecare as not to...