Page 3 - GENERAL INFORMATION; Installation and repair should be per-; Table 1; TABLE OF CONTENTS; INTRODUCTION
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. These appliances comply with National Safety Standards and are tested and listed by Omni-Test Laboratories (Report No. 116-F-31-5) to ANSI ZZ21.88b-2003 (in Canada, CSA-2.33b-2003), and CAN/CGA-2.17-M91 in both USA and Canada, as vented gas fi repla...
Page 4 - Table 7; Cleaning Glass; must be disconnected; greater; by closing their; less than; show the appliances' gas; Table 5; Figures 4 or 5; Figure 1; Figure; Control Valve
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Burner Orifi ce Sizes Elevation 0-4500 feet ( 0-1372 meters) Model Series Natural Gas drill size (inches) Propane Gas drill size (inches) LMDVT-3328LMDVR-3328 #45 (.082") * 39L66 • 1.2 mm (.048") * 99K78 • LMDV-3530 #44 (.086") * 60J80 •...
Page 5 - Millivolt Appliances; Figure 2; Honeywell Millivolt Gas Valve; Figure 5; Figure 3; SIT Millivolt Gas Valve; Figure 4; Honeywell Electronic Gas Valve; Electronic Appliances -
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 2 Sit and Honeywell Millivolt Gas Valve Showing Piezo Igniter Location (Each Unit is Equipped with Only One of these Gas Valves) Millivolt Appliances - Appliances with Millivolt systems will be fi tted with the gas control valve shown in Figu...
Page 6 - MAINTENANCE; IMPORTANT; Flame Appearance and
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3. Keep the lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, pet hair, etc. It is very important that the control compartm...
Page 7 - EXERCISE EXTREME CAUTION; INSTALLING GLASS DOOR; Figure 6
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 WARNING Handle this glass with extreme care! Tempered glass is suscep-tible to damage – do not scratch or handle roughly while rein-stalling the glass door frame. Front Glass Enclosure Panel, Removal and Installation WARNING Do not operate appliance...
Page 8 - REFERENCE; Table 8; Bag of Glowing; Removing Glass Enclosure Panels; Handle logs carefully to prevent; Note; WARNING; Figure 7; WARNING
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING The size and position of the log set was engineered to give the appliance a safe, reliable and attractive fl ame pattern. Any attempt to use a different log set in the fi replace will void the warranty and will result in incomplete combustio...
Page 9 - Figure 8; LOG SET; DO NOT PLACE EMBERS OVER GAS SLOTS
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 8 MODEL LMDV-3328 & LMDV-3530Log Placement Instructions LOG SET Catalog Number H3366 * Item Description A Log, Rear B Log, Left C Log, Left Center D Log, Right Center E Log, Right * Item "letters" above correspond to photos D C E ...
Page 10 - Figure 9
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 9 MODEL LMDV-4035 Log Placement Instructions LOG SET Catalog Number H3365 * Item Description A Log, Rear B Log, Left C Log, Center D Log, Center Front E Log, Right * Item "letters" above correspond to photos Install the Embers, Vermi...
Page 11 - • If there is smoke or soot present, fi rst check
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. BURNER ADJUSTMENTS (QUALIFIED TECHNICIANS ONLY) Flame Appearance and sooting Proper fl ame appearance is a fl ame which is blue at the base and becomes yellowish-orange in the body of the fl ame. When the appliance is fi rst lit, the entire fl ame ...
Page 12 - Burner Air Shutter Adjustment Procedure; Burner Air Shutter Adjustment
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Natural Gas Propane Gas LMDVT-3328 1/16" (1.58 mm) 1/4" (6.35 mm) LMDVR-3328 1/16" (1.58 mm) 1/4" (6.35 mm) LMDV-3530 1/16" (1.58 mm) 5/16" (7.94 mm...
Page 13 - TP; Thermopile; Standard OFF/ON Switch; CAUTION; Schematic Representation Only
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS A complete parts list is found at the end of this manual. Use only parts supplied from the manufacturer. Normally, all parts should be ordered through your Lennox distributor or dealer. Parts will be shipped at prevailing prices a...
Page 14 - ACCESSORY COMPONENTS; Wall Thermostat; Product Reference Information; Model; Arch Door Kits
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. ACCESSORY COMPONENTS Remote Control Kit, Standard Cat. No. Model No. Description H0249 RCL Remote Control System (Standard) (ref. Form # 750,127M) Remote Control Kit, Deluxe Cat. No. Model No. Description H0251 RCL-STAT Remote Control System (Delux...
Page 15 - Arch Design; Screen Panel Kit; Decorative Arch Screen Panel Kit
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Style View Screen Doors - These Style View screen doors come in 4 beautiful styles. They are easy to install and will not require hardware to attach them to the standard glass door frame. The screens prevent direct contact with the hot glass surfac...
Page 16 - Forced Air Kit; Variable Speed Wall Switch; OFF/ON Wall Switch Kit; The OFF/ON wall switch kit may be used to control
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Piece Trim Kit Cat. No. Model No. Description H0453 TK33PB3 33” Polished Brass, LMDVT-3328, LMDVR-3328 96K21 TK35PB3 35” Polished Brass,LMDV-3530 96K22 TK40PB3 40" Polished Brass, LMDV-4035 H1813 TK33BS3 33” Brushed Stainless, LMDVT-3328, LMD...
Page 17 - Polished Brass & Brushed Stainless 2-Piece Door Frame Kits; - Piece Door Frame Kits; Polished Brass & Brushed Stainless Louvers Kits; Eyebrow Hood Kits; Door Frame Kits; Piece Door Trim Kits
17 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Bag of Glowing EmbersBag of Volcanic Stone Replacement ember materials or volcanic stone are available for use with these appliances. Order kits as part of the periodic maintenance of the appliance. Decorative Firebox Accessories (all models) Cat. ...
Page 18 - LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE; FOR YOUR SAFETY READ BEFORE LIGHTING; Knob cannot be turned from “PILOT” to “OFF”; SIT
18 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. LIGHTING INSTRUCTIONS – HONEYWELL AND SIT MILLIVOLT GAS VALVE WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. FOR YOUR SAFETY READ BEFORE LIGHTING A....
Page 19 - INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT; INSTRUCTIONS D'ALLUMAGE; Il est impossible de tourner le bouton de “PILOT” à “OFF” à; POUR FERMER LE GAZ QUI ALIMENTE L’APPAREIL; VANNE GAZ; HONEYWELL
19 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE – VANNE GAZ MILLIVOLT HONEYWELL ET SIT INSTRUCTIONS D'ALLUMAGE 8. Enfoncez le bouton de réglage jusqu’au fond et gardez-le enfoncé.Allumez immédiatement la veilleuse en déclen...
Page 20 - LIGHTING INSTRUCTIONS — ELECTRONIC; TO TURN OFF GAS TO APPLIANCE; Honeywell Electronic Gas Control Valve
20 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. When lighting the appliance, follow these instructions exactly. B. BEFORE OPERATING smell all arou...
Page 21 - INSTRUCTIONS D’ALLUMAGE — ELECTRONIC; INSTRUCTIONS D’ALLUMAGE; POUR ÉTEINDRE L’APPAREIL; Interrupteur; Vue de face
21 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTRUCTIONS D’ALLUMAGE — ELECTRONIC INSTRUCTIONS D’ALLUMAGE POUR VOTRE SÉCURITÉ, LISEZ CES INSTRUCTIONS AVANT L’ALLUMAGE A. Lorsque vous allumez l’appareil, suivez exactement ces instruc-tions. B. A...
Page 22 - Periodically
22 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. MAINTENANCE TASK ACCOMPLISHING PERSON PROCEDURE Inspecting/Cleaning Burner, Logs and Controls Qualifi ed Service Technician Inspect valve and ensure it is properly operating. Check piping for leaks. Vacuum the control compartment, fi replace logs a...
Page 23 - TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM; on; TROUBLESHOOTING GUIDE - ELECTRONIC IGNITION SYSTEM
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 23 TROUBLESHOOTING GUIDE - MILLIVOLT GAS CONTROL SYSTEM Note: Before troubleshooting the gas control system, Ensure external gas shut off valve, located at gas supply inlet, (and wall switch, iff applicable), is in the “ON” position. Important: Valve ...
Page 24 - TROUBLESHOOTING PROCEDURE - ELECTRONIC IGNITION SYSTEM
24 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. START CHECK • Turn Off Gas Supply. • Ensure Valve Switch Is In ON Position. • Disconnect Control Harness. • Set Thermostat To Call For Heat. • Check for proper volt- age at control harness (see insert A). Voltage should be 24V between thermostat or...
Page 26 - REPLACEMENT PARTS
26 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. REPLACEMENT PARTS 7 8 1 2 9 10 13 12 6 19 11 3 5 15 18 16 14 17 4 24 25 26 27 23 22 30 29 32 28 20 31 21 8 LMDV-4035 LMDVT-3328 & LMDVR-3530
Page 27 - NOTES
27 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. NOTES