Page 2 - Cautions and Safety
FOR YOUR SAFETY do not install or operate your Epic™ gas stove without first reading and understanding this manual. Any installation or operation of the appliance deviating from that which is stated in this manual WILL void the warranty and may be hazardous. INSTALLATION AND REPAIR SHOULD ONLY B...
Page 3 - Table of Contents
3 Table of Contents Cautions and Safety ....................................................................................................... Orifice Size / Altitude Adjustment ....................................................................................... 4 Codes and Approvals ..............
Page 4 - Certification
4 Orifice Size/Altitude Adjustment For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M),the orifice should be de-rated by 4% for every 1,000 feet to maintain the proper ratio of gas to air. Improper orifice sizing may result in damage and unsafe conditions. Chang- ing the orifice should only b...
Page 6 - Features; RATINGS; NATURAL GAS; P4 Efficiency
6 Pre-Installation Features Installation Options Residential Vented vertical and horizontal Manufactured (mobile) home Natural gas (NG) or propane (LP) Bedrooms Optional wall-mounted or remote thermostat Venting This stove can be vented with Security™ Secure Vent™ pipe*. Coaxial pipe diameters are 6...
Page 7 - Figure 1
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Dimensions The gas line attaches to the gas valve at the lower left corner at the back of the stove. Test all gas connections for leaks with a gas leak test solution. Preparing Your Epic™ Stove For Installation Read all instructions before begin...
Page 8 - Clearances to Combustibles; Parallel Installation; Alcove dimensions; Alcove Dimensions; Figure 3; Pipe Clearances
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Clearances to Combustibles Minimum clearances to combustible materials in inches (millimeters): Parallel Installation Corner Installation Alcove dimensions The minimum width between the alcove side walls is 48” (1219mm). The minimum height of th...
Page 9 - Installation; Figure 6
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Installation Trim Installation: CAUTION: Always ensure that plated surfaces are clean and free of fingerprints before lighting stove. Fingerprints will leave permanent blemishes if left on plated surface when lit. When installation is complete, ...
Page 10 - Do not cover any secondary air holes or gas ports (see; Burner Pan Diagram; Firebox Setup; Figure 7
0 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Log Stands Secondary Air Holes Air Deflector Gas Ports 3 4 Do not cover any secondary air holes or gas ports (see Burner Pan Diagram above) behind this line. To ensure a proper burn leave a ” space free of any embers or rockwool directly in fron...
Page 11 - Brick Panel Installation; CAUTION: The brick panels are required for your appli-; Figure 9
Brick Panel Installation CAUTION: The brick panels are required for your appli- ance to function correctly and safely. Packaging List: Rear brick panel ( A ), left brick panel ( B ), right brick panel ( C ), retaining brackets ( D ) - in flue restrictor bag 1. Remove the brick panels from the box an...
Page 12 - Log Set and Ember Installation; NOTE: All logs are designed to fit only one way. For the
A B C D E F C D B A Log Set and Ember Installation If logs are not installed according to the log installation instructions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas. The size and po...
Page 13 - Vent Installation; Page 16. Consult your local building codes; Residential and Mobile Home Installations:
3 Vent Installation Venting: The Epic™ gas stove has been tested and listed as a direct vent heater system by OMNI-Test Laboratories, Beaver- ton, Oregon and is recommended for use with Security™ Secure Vent pipe*. Use only approved chimney brands with this appliance. Important: • Read all instructi...
Page 14 - Vent Parts List; Part Number; Horizontal Vent Installation
4 Vent Parts List Direct vent pipe Security™ Secure Vent™ * may be used with the Epic™ gas stove. Please see the lists below to verify the components available from each direct vent pipe manu- facturer. Snorkel terminations are available for applications which may require vertical rise on the buildi...
Page 15 - Vertical Vent Installation; Important Notes; Flue Restrictors
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Vertical Vent Installation Important Notes 1. All vertically terminated vent installations use 6-5/8”x 4” Security™ Secure Vent™ pipe*. 2. If the vent passes through a ceiling or floor, a firestop - Simpson #963 or Security™ #SV4BF - is required...
Page 16 - Vertical Terminations; NOTE: Horizontal pipe requires 1/4” rise for every 12”; Horizontal Terminations
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 2 4 6 8 10 12 14 16 18 20 2 4 6 8 10 12 14 16 18 20 22 24 26 28 MIN. 24" VERT. PIPE SECT.WITH 9" HORIZONTAL SECT. 8' MAX 30' MAX 30 19' 7" MAX VERT. WITH 8' HORIZONTAL VERTICAL HEIGHT (FT) 2 4 6 8 2 4 6 8 VERTICAL HEIGHT (FT) HORIZON...
Page 17 - Exterior Horizontal Vent Termination Clearance Requirements; Minimum Clearances
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Exterior Horizontal Vent Termination Clearance Requirements V V V V V F C B B A B H M I X V D V A A A V L B J X E V A G *18” 18” B C C C * See Item D in the Text Below. Center Line of Termination Exterior Wall Horizontal Termination Ventilated S...
Page 18 - Gas Line Installation; Gas Pressure Requirements; A MAJOR CAUSE OF OPERATING PROBLEMS WITH GAS; LP and Natural Gas Supplies:; Check all connections
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Gas Line Installation This stove must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the current CAN/CSA B149.1 installa- tion code). Remove the four screws holding the back...
Page 19 - OPERATING INSTRUCTIONS; Operating Instructions; Lighting Instructions:
9 WHAT TO DO IF YOU SMELL GAS: DO NOT try to light the appliance. DO NOT touch any electric switch. DO NOT use any phone in the building. Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. If you cannot reach your gas supplier, call the fire departmen...
Page 20 - Flame Color and Behavior; TO TURN OFF GAS TO APPLIANCE; Burner Flame Appearance; WARNINGS
0 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Flame Color and Behavior Your stove is designed for maximum heating efficiency. Therefore, upon lighting of the main burner the flames will be semitransparent or “bluish.” After 10-20 minutes of operation, the logs will heat up and the flames wi...
Page 21 - Air Shutter Adjustment Handle, highlighted
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Pilot Flame Appearance Figure 31 Air Shutter Adjustment CAUTION: Air shutter is hot while the Epic™ gas stove is operating and should only be adjusted using a heat resistant glove. The air shutter control lever is located inside the main control d...
Page 22 - Operating Options; Millivolt Control Schematic; Millivolt Control System; CAUTION: Label all wires prior to disconnection when; Gas Valve
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Operating Options Your stove comes equipped with an “On/Off” rocker switch used to turn the burner on and off while the pilot light is on. The switch is a round rocker switch located behind the main control panel door. A millivolt wall thermostat,...
Page 23 - Maintenance and Servicing; Maintenance Checklist:
3 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Maintenance and Servicing Maintenance Checklist: The following should only be performed by a qualified service technician. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous op...
Page 25 - Opening and Removing Door; CAUTION: Do not attempt to open the main door while
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Opening and Removing Door If the glass in your door is damaged or broken - the com- plete door assembly must be replaced using part #45715. CAUTION: Do not attempt to open the main door while the unit is burning or still hot. Let the unit cool b...
Page 26 - CAUTION: Label all wires prior to disconnection when
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Fuel Conversion Converting the stove between natural gas (NG) and propane (LP) can be accomplished by either changing the cassette (valve and pilot assembly) or installing a conversion kit (regulator, burner orifice and repositioning the slide o...
Page 27 - Troubleshooting; ply inlet is in the “ON” position.; SYMPTOM
7 Troubleshooting NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas sup- ply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should ...
Page 28 - Parts List
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 1 2 4 15 19 21 12 27 28 29 3 6 7 10 18 11 13 30 14 20 22 23 24 25 26 31 16 17 8 5 32 9 Parts List NO. DESCRIPTION 1 FRONT DOOR 2 RIGHT BURNER SUPPORT 3 LEFT BURNER SUPPORT 4 BURNER PAN / LOG SET 5 BRICK PANEL SET 6 BRICK PANEL SET 7 BRICK PANEL ...
Page 30 - Wire Harness Diagram; dangerous operation. Verify proper operation after servicing.; POWER CORD; RING LUG CRIMP
30 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Wire Harness Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. POWER CORD SNAP SWITCH SPEED CONTROLSWITCH BLOWER M...
Page 31 - Replacement Parts List; Description
3 Replacement Parts List Epic™ 33/40 (EPIC33/40) Diagram No. Part No. Description 1 H3102 Front Door 2 H5835 Burner Support, Right 3 H5834 Burner Support, Left 4 H3137 Burner Pan 5,6,7 H5872 Brick Panel Set 8 H5836 Brick Panel Bracket 10,11 H3124 Heat Exchanger Kit 12,13 H6014 Side Door 14 H5875 Sna...
Page 32 - Accessories
3 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Trim Kits Kits Include: Matching Trim for Glass (Upper and Lower) Cat. No. Description 75348 Black Trim, EPIC-TRIM-B 75349 Gold Trim, EPIC-TRIM-G 75350 Brushed Nickel Trim, EPIC-TRIM-BN 7535 Black Nickel Trim, EPIC-TRIM-BKN Accessories Gas Conve...
Page 33 - Lighting Label; FOR YOUR SAFETY READ BEFORE OPERATING
33 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Lighting Label CAUTION: YOUR COUNTRY GAS APPLIANCE MUST ALWAYS BE OPERATED WITH GLASS DOOR IN PLACE. STOP! Read the safety information above before proceeding. 1. Open the lower door. Make sure gas supply shut-off cocks are open and ON/OFF Rock...
Page 34 - Safety / Listing Label
34 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Safety / Listing Label MODEL MODÈLE EPIC™ NG 40 MANUFACTURED BY: LENNOX HEARTH PRODUCTS PO BOX 987 AUBURN, WA., USA 98071 SERIAL NO. NUMÉRO DE SÉRIE Report No. / Número de Rapport 050-S-21b-5 RATINGS EPIC 33 EPIC 40 NATURAL GAS LP GAS NATURAL G...
Page 35 - Notes
35 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Notes
Page 36 - Natural Gas; WARRANTY
36 Your Stove's Model Number __________________________________________Your Stove's Serial Number ___________________________________________The Date On Which Your Stove Was Installed _____________________________The Type of Gas Your Stove's Uses _____________________________________Your Dealer's Na...