Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...
Page 4 - Table 4; Series; Table 5; REQUIREMENTS FOR THE COMMON-; Table 3; Table 2
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 2 - Dexen Electronic Gas Valve Pilot Stage Terminal Pressure-Tap (Inlet) Pilot Gas Outlet Supply Gas Inlet Pressure-Tap (Manifold) Burner Stage Terminal Ground (TP) PILOT OUT VENT LO TH TP TH TP HI IN IN Regulator Mounting Screw Test gaug...
Page 5 - Figure 3; Typical Locations; HORIZONTAL VENT; When the unit is installed with one; LOCATION; Due to high temperatures, the appliance
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. • A hard wired carbon monoxide detector with an alarm and battery back-up must be installed on the floor level where the gas fireplace is installed. The carbon monoxide detector must comply with NFPA 720, be ANSI/UL 2034 listed and be ISA certif...
Page 6 - VENT TERMINATION CLEARANCES; Termination Heights For Vents; Figure 6; Side Elevation View; Minimum; Figure 4 - Multiple Terminations
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Termination...
Page 7 - EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 7
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Figure 7 V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted = Air Supply Inlet X = Vent Termination V D V 3 ft. 3 ft. A A A = 9” i...
Page 8 - Top Vent - with One 90 Degree Elbow; MINIMUM CLEARANCES TO COMBUSTIBLES; When the; Hearth Extension; Combustible wall finish materials and/or surround materials; Table 6
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 5 (127) 8-1/4 (209) 14 (356) 12 (305) 17 (431) *Shelf Height ( see table) Do not insulate the space between the appliance and the area above it. Shelf Above Fireplace With Top Venting 6 (152) 2 (51) 4 (102) 6 (152) 8 (203) 10 (254) 12 (305) 8 (2...
Page 9 - DETAILED INSTALLATION STEPS; Figure 12 - Nailing Flanges; Figures; DO NOT; the 1/2” clearance to combustible requirements; TYPICAL INSTALLATION SEQUENCE
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi- cally approved with this appliance may result in property damage or personal injury. AVERTISSEMENT Risque de dommages ou de blessures s...
Page 10 - FIREPLACE AND FRAMING SPECIFICATIONS; Frame ceiling opening; Framing
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. FIREPLACE AND FRAMING SPECIFICATIONS Vent Size Co-axial DV Vent Size 4-1/2" Inner 7-1/2" Outer Vertical Venting Through the Ceiling: Frame ceiling opening - Use a plumb line from the ceiling above the appliance to locate center of the v...
Page 11 - Table 7; Proper Sizing of Gas Line; Figure 15 - Route Gas Line; Step 2. ROUTING GAS LINE
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. FIREPLACE FRAMING SPECIFICATIONS Figure 14 - Corner Framing with Horizontal Termination Schedule 40 Black Iron Pipe Inside Diameter (Inches) Schedule 40 Pipe Length (feet) Natural Gas Propane Gas 0-10 1/2 3/8 10-40 1/2 1/2 40-100 1/2 1/2 100-15...
Page 12 - Approved Vent Components; Exhaust Vent; Figure
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 3. INSTALL THE VENT SYSTEM General Information These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (...
Page 13 - Note: Convert inches into metric equivalent; Effective Vent Length; Model; Table 8; Figures 25 through; Secure VentTM; Figure 5; on; Tables on this page
13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Note: Convert inches into metric equivalent measurement, as follows: Millimeters (mm) = Inches x 25.4 Centimeters (cm) = Inches x 2.54 Meters (M) = Inches x .0254 T R A H C H T G N E L N O I T C E S T N E V l a n i m o N h t g n e L n o it c e ...
Page 15 - Swivel Joint; Figure 22 - Roof Framing; Storm
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. If the vent system extends more than 5 feet (1.5m) above the roof flashing, stabilizers may be necessary. Additional screws may be used at section joints for added stability. Guide wires may be attached to the joint for additional sup- port on ...
Page 16 - as shown in; be used in this; VERTICAL VENT FIGURES/TABLES; • Secure VentTM (rigid vent pipe) is shown; rate sections of concentric flexible; Note: Install a second; V M; vent will be required.
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. u Ceiling Firestop / Spacer (SV4.5VF) v When using Se- cure Flex, use Firestop / Spac- er SF4.5VF A Vent Restrictor, as shown in Figure 16 Page 12 , must be used in this application Figure 25 - Top Vent - STRAIGHT 40 feet (12.2 meters) Maximum ...
Page 17 - Ceiling; Top Vent - THREE ELBOWS; Figures 31
17 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Maintain a minimum 1" (25 mm) clearance to combustibles on the vertical sections. Clear- ances for the horizontal runs are; 3" (76 mm) on top, 1" (25 mm) on sides, and 1" (25 mm) at the bottom. B. Frame exterior wall opening - L...
Page 18 - horizontal/inclined run be maintained in a
18 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Support Brackets Building Support Framing SV4.5E90 Elbow Ceiling Fireplace SV4.5L6/12/24/36/48 Vent Sections Vertical Rise Support Bracket Spacing Every 5 ft (1.52 m) TYPICAL HORIZONTAL VENT INSTALLATION u When Using Secure Flex™, Use Firestop ...
Page 19 - tion Guard; INSTALLING HORIZONTAL TERMINATION; Venting Connection and Exterior Wall Recessing; Table 9; See
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. J. Assemble vent run to exterior wall - If not previously measured, locate the center of the vent at the exterior wall. Prepare an opening as described in Step B and Figure 29 . Assemble the vent system to point where the terminus of the last s...
Page 20 - HORIZONTAL VENT FIGURES/TABLES; • Secure VentTM components (rigid vent pipe and terminal) are shown; ELBOW CONNECTION NOT DIRECTLY AT APPLIANCE; Typical termination shown.; Venting Components Required for Various Exterior Wall Thick-; Termination Kit Only; zontal vent run is needed, then; Under no circumstances, may separate sections of
20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. See Table 9 as an aid in venting component selection for a particular range of exterior wall thicknesses. HORIZONTAL VENT FIGURES/TABLES Notes: • Secure Vent™ components (rigid vent pipe and terminal) are shown in the Figures; Secure Flex™ comp...
Page 21 - Top Vent - TWO 90 DEGREE ELBOWS; See Table 9 on Page 20 as an aid in venting component selection for; When using Secure Flex,; Wall
21 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 32 - Top Vent - TWO 90 DEGREE ELBOWS See Table 9 on Page 20 as an aid in venting component selection for a particular range of exterior wall thicknesses. Example: If 20 feet of (H + H 1 ) horizontal vent run is needed, then 4 feet minimu...
Page 22 - Section Required; ) horizontal run, up to a maximum horizontal; Top Vent - THREE 90 DEGREE ELBOWS
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. V H H1 V1 Wall Firestop/Spacer (SV4.5HF) Ceiling Firestop/Spacer (SV4.5VF) When using Secure Flex TM, use Firestop/Spacer SF4.5VF. When using Secure Flex, use Firestop/Spacer SF4.5HF. Wall Firestop/Spacer (SV4.5HF) v v u Min. One Foot Vent Sect...
Page 23 - SECuRE FLExTM
23 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. D. Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceiling, a firestop / spacer is required: use the SF4.5 VF firestop / spacer for ceilings and the SF4.5 HF firestop / spacer for walls. See the appropri...
Page 24 - Page; INTERMITTENT ELECTRONIC WIRING DIAGRAM; CAUTION; Verify proper operation after servicing.
24 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 4. FIELD WIRING B. Electronic Wiring (See Figure 37 ) – Note: The electronic appliance must be con- nected to the main power supply. 1 . Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box. 2 . Remove the electrical i...
Page 25 - BLOWER CONTROL CIRCUIT WIRING; Junction Box; WIRING - OPTIONAL FORCED AIR; Blower Access
25 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Note: Remote receiver should be located in the wall, or if installed in the control compartment, pulled all the way forward and completely to the left or right against the corner posts. The door must be removed first to place the receiver in th...
Page 27 - Never use an open flame to; TION
27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Turn on gas supply and test for gas leaks, us- ing a gas leak test solution (also referred to as bubble leak solution). Note: Using a soapy water solution is an effective leak test solution but it is not recom- mended, because the soap residue ...
Page 28 - Glowing Embers; Bag of Glowing; Remove the front glass enclosure panel
28 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. REFERENCE Firebox Accessories / Parts Cat. No. Model No. Description 88L53 FGE Bag of Glowing Embers 80L42 FDVS Bag of Decorative Volcanic Stone Glowing Embers Bag of Glowing Embers (rockwool) Separate into Quarter Size (separate) Pieces Step 8...
Page 29 - Catalog Number for the entire
29 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. ELDV3530 LOG PLACEMENT Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front 4 Log, Left 5 Log, Right Catalog Number for the entire log set: H4656 Align holes at the bottom of log (1) over the pins on the burner Align holes at the botto...
Page 31 - Catalog Number for the entire log
31 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front 4 Log, Left 5 Log, Right 6 Log, Right/Rear 7 Log, Left/Rear Catalog Number for the entire log set: H4658 ELDV4540 LOG PLACEMENT (REPEAT STEPS 1 THRU 4 FROM ELDV4035 LOG PLACEMENT AND...
Page 32 - ) by lifting and pulling the
32 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 9. REMOVING AND INSTALLING THE GLASS DOOR Air Shutter Adjustment Guidelines : Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be orange Air shutter gap should be increased If air shutter...
Page 33 - Move the adjustment rod down to; Burner Air Shutter Adjustment Procedure
33 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNINGS • Air shutter adjustment should only be performed by a quali- fied professional service tech- nician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Soot will be produced if the air shutter is closed t...
Page 34 - HOOD INSTALLATION; angled air plenum ramp above the opening above the door.; FINISHING REQUIREMENTS - Wall Details; framework to accommodate the thickness of the finished wall (; See Page 5 for Cold Climate Insulation
34 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 11. HOOD INSTALLATION The hood is optional for these products. In "Shadow Box" installations, the hood may not be desired. If the opening above the door is objectionable (as is the case in certain "Flush-Mounted" installati...
Page 35 - COLOCACIóN DE ADVERTENCIAS DE; ) o en el termostato; LENNOX HEARTH PRODUCTS; WARNINGS; ). The warnings should already have been; LENNOX HEARTH PRODUCTS; Figure A
35 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. STEP 12. ATTACHING SAFETY-IN-OPERATION WARNINGSIt is the installer ' s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this a...
Page 36 - rigid; INSTALLATION ACCESSORIES; Listed Secure VentTM Components
36 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Cat. No. Model Description 77L70 SV4.5L6 6 Inch (152 mm) 77L71 SV4.5L12 12 Inch (305 mm) 77L72 SV4.5L24 24 Inch (610 mm) 77L73 SV4.5L36 36 Inch (914 mm) 77L74 SV4.5L48 48 Inch (1219 mm) 77L75 SV4.5LA Telescopic Length Slip Sec- tion (2" to ...
Page 37 - INSTALLATION ACCESSORIES CONTINUED; All compressed flex vents can be expanded up to two times.
37 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Cat. # Model Description H1969 SF4.5HT-2 Horizontal Square Termina- tion for flex (without flex) 77L87 SFKIT12S Square Term. for flex (with 12 inch [305 mm] * compressed flex) 77L88 SFKIT18S Square Term. for flex (with 18 inch [457 mm] * compre...
Page 38 - this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.
38 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. ELDV-35 H3960 ELDV-40 H7252 ELDV-45 H7254 Millivolt SIT Systems Natural Gas To Propane Gas Conversion Kits Models Catalog No. ELDV-35 85L62 ELDV-40 H7257 ELDV-4...
Page 39 - Millivolt Appliances; ment kit is available, order Catalog Number; and replace the pilot orifice as; ELECTRONIC
39 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 55 Millivolt Appliances Step 5. SIT Systems - Refer to Figure 56 and the instructions provided with the kit. Using a Torx T20 (with 1/4" shank and center hole), remove and discard the three pressure regulator mounting screws. Remove ...