Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...
Page 3 - Table 1
3 WARNING Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING Failure to comply with these installation i...
Page 4 - REQUIREMENTS FOR THE COMMON-; Tables 2 and 3; SIT Millivolt Gas Valve
4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Test gauge connections are provided on the front of the millivolt and electronic gas control valve (identified IN for the inlet and OUT for the manifold side). The control valves have a 3/8" (10mm) NPT thread inlet and outlet side of the val...
Page 5 - LOCATION; peu de circulation et loin du mobilier et des tentures (Figure 3).; COLD CLIMATE INSULATION; Figure 3; TYPICAL LOCATION
5 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. LOCATION In selecting the location, the aesthetic and functional use of the appliance are primary concerns. However, vent system routing to the exterior and access to the fuel supply are also important. Due to high temperatures, the appliance sh...
Page 6 - VENT TERMINATION CLEARANCES; Termination Heights For Vents; Figure 6; Side Elevation View; Figure 4 - Multiple Terminations; Minimum
6 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING OF VENT TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS Horizontal Overhang Vertical Wall Vent Termination...
Page 7 - EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
7 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS V V V V V F C Fixed Closed Window Operable Window B B A B H M I = Area where Termination is not Permitted = Air Supply Inlet X = Vent Termination V D V 3 ft. 3 ft. A A A = 9” in U.S. = ...
Page 8 - When the unit is installed with one side flush with a; Hearth Extension; the space between the appliance and the area; or surround materials must not be allowed to; Shelf Height Minimum Clearances
8 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. MINIMUM CLEARANCES TO COMBUSTIBLES Appliance And Vent Clearances The appliance is approved with zero clearance to combustible materials on all sides (as detailed in Table 5) , with the following exception: When the unit is installed with one sid...
Page 9 - Top; Table 5; Unit Parts Identification; See; Figure 9
9 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. AVERTISSEMENT Risque de dommages ou de blessures si ...
Page 10 - Figure 12 - Nailing Flanges; TYPICAL INSTALLATION SEQUENCE; refer
10 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Figure 11 REMOVE CARDBOARD BEFORE USING Pressure Relief Plates Remove Cardboard Before Using Appliance REMOVE CARDBOARD BEFORE USING Figure 12 - Nailing Flanges TYPICAL INSTALLATION SEQUENCE The typical sequence of installation is outlined belo...
Page 11 - EDVST; EDVPF; FIREPLACE FRAMING SPECIFICATIONS
11 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Gas Line Center of gas line is 3 in. (76 mm) up from floor. *41-1/2 (1054) ***48-1/2 (1232) 26-3/4 (679) 11-3/8 (267) Dimension A Secure Vent - 47-1/8 (1197) Secure Flex - 47-3/4 (1213) 7 (178) 5-1/8 (130) 12-1/8 (308) 10-1/2 **22-3/4 (578) EDV...
Page 12 - FLUE; FIREPLACE SPECIFICATIONS
12 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 12 (305) 10 (254) TOP VIEW 40-1/8 (1019) 3-1/2 (89) 5/8 (16) Stepped to Accept Drywall on Two Corners FRAMING SPACERS (Top and Side) FINISH WALL BRACKET (Front, back, and left edge of unit top) 6-7/8 (175) 10-1/4 (260) 12 (305) (63.5) RIGHT SID...
Page 13 - FIREPLACE SPECIFICATIONS CONTINUED
13 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 41 (1041) 37 (940) 43-5/8 (1108) 6-7/8 (175) 10-1/4 (260) 12 (305) 12 (305) 10 (254) 1/2 13) (63.6) FRONT VIEW RIGHT SIDE VIEW LEFT SIDE VIEW TOP VIEW 3 (76) 4 (102) FLUE (Top or Side) 40-1/8 (1019) 3-1/2 (89) FLUE (Top or Side) GAS INLET ELECT...
Page 14 - Table 6; Step 3. PREPARING THE APPLIANCE; Figure 21 - Route Gas Line; Step 2. ROUTING GAS LINE
14 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Schedule 40 Black Iron Pipe Inside Diameter (Inches) Schedule 40 Pipe Length (feet) Natural Gas Propane Gas 0-10 1/2 3/8 10-40 1/2 1/2 40-100 1/2 1/2 100-150 3/4 1/2 150-200 3/4 1/2 Table 6 IMPORTANT: If propane is used, be aware that if tank s...
Page 15 - Approved Vent; on; the joints in the vent pipe.; restrictor in the top vent of the fireplace outlet.
15 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Securing Screws (OUTSIDE of Appli ance) Insulation Top Vent Vent Seal Cap Firebox Top Cabinet Top CROSS SECTION SIDE VENT SEAL CAP REMOVAL (SIDE VENT INSTALLATIONS ONLY) Insulation Vent Seal Cap Securing Screws Side Vent Cabinet Back CROSS SECT...
Page 16 - Note: Convert inches into metric equivalent; Effective Vent Length; Model; Table 7; Figures 35 through 39; Secure FlexTM pipe may also be used. A Vertical; Figure 5; Tables on this page
16 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Note: Convert inches into metric equivalent measurement, as follows: Millimeters (mm) = Inches x 25.4 Centimeters (cm) = Inches x 2.54 Meters (M) = Inches x .0254 T R A H C H T G N E L N O I T C E S T N E V l a n i m o N h t g n e L n o it c e ...
Page 19 - VERTICAL VENT FIGURES/TABLES; which is ideal, though rise per foot run ratios; rate sections of concentric flexible; Ratio V to H ratio is 1:2
19 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. VERTICAL VENT FIGURES/TABLES Note: Secure Vent (rigid vent pipe) is shown in the figures; Secure Flex (flexible vent pipe) may also be used. Note: It is very important that the horizontal/ inclined run be maintained in a straight (no dips) and ...
Page 20 - Ceiling; ) horizontal vent run is needed, then 4 feet minimum; Top Vent - THREE ELBOWS
20 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. VERTICAL VENT FIGURES / TABLES (CONTINUED) H1 V V1 H Table C H +H 1 Maximum H Maximum V Minimum feet (meter) feet (meter) feet (meter) 5 (1.524) 2 (0.610) 1 (0.305) 10 (3.048) 4 (1.219) 2 (0.610) 15 (4.572) 6 (1.829) 3 (0.914) 20 (6.096) 8 (2.4...
Page 22 - tion Guard; Figure; Venting Connection and Exterior Wall Recessing of the
22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. IMPORTANT: The vent termination is hot while in operation and for a period of time following the use of the fireplace. To prevent contact with hot surfaces, we recommend the use of a Termina- tion Guard . See Page 39. This can be purchased at y...
Page 23 - Table 8; HORIZONTAL VENT FIGURES/TABLES; Note: Two 45 degree elbows may be used in place of one 90 degree; When using; Under no circumstances, may separate sections of
23 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness - inches (mm)Termination Kit Only 6 to 9-1/4 (152 to 235) Termination Kit and 6 In. Vent Sec...
Page 24 - ) horizontal run, up to a maximum horizontal
24 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. HORIZONTAL VENT FIGURES/TABLES (continued) H1 V H V H H1 u When using Secure Flex, use Firestop / Spacer SF4.5VF v When using Secure Flex, use Firestop / Spacer SF4.5HF u When using Secure Flex, use Firestop / Spacer SF4.5VF v When using Secure...
Page 26 - SECuRE FlEx; Secure Flex
26 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. GEAR CLAMPS Adapter (SV4.5RF) Apply ONLY MIL-PAC BLACK HIGH TEMPERATURE SEALANT (Catalog No. 10K81) to the outside surface of both collars of the adapter (be especially careful to fill the grooves of the outer collar to be covered by the flexib...
Page 27 - Verify proper operation after servicing.; CAUTION
27 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Step 5. FIELD WIRING TP-TH TP TH APPLIANCE- MOUNTED ON/OFF SWITCH (OPTIONAL) BK/W(1) BK/W(1) WALL-MOUNTED ON/OFF SWITCH (OPTIONAL) THERMOSTAT (OPTIONAL) JUNCTION BOX BLACK W GR 120 V AC WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL) BK R ...
Page 28 - WIRING - OPTIONAL FORCED AIR; 50 forced air blower kits. Electrical power; Valve Access Side; Step 7. CONNECTING GAS LINE; Secure all joints tightly using appropriate; Remove the carton support from; Never use an open flame to; TEST ALL CONNECTIONS FOR GAS LEAKS
28 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Note: Supply wires may be alternatively con- nected to the outlet using the screw terminals, however the black supply wire must be wired to a terminal that is opposite (across the outlet) the point where the white supply wire is connected. Bipo...
Page 29 - Note: using a soapy water solution is an; A. Light the appliance (refer to the lighting; TION; Note: lighting Instructions are also found on; Schematic Representation Only
29 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Turn on gas supply and test for gas leaks, us- ing a gas leak test solution (also referred to as bubble leak solution). Note: using a soapy water solution is an effective leak test solution but it is not recom- mended, because the soap residue ...
Page 30 - Millivolt Appliance Checkout; ING EMBERS AND LOGS; NOTE: Turn off all electricity to the appliance; Electronic Appliance Checkout
30 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the instruc- tion manual. Subsequent lighting of the applia...
Page 31 - Remove the front glass enclosure panel; DO NOT PLACE ANY VERMICULITE ON THE BURNER.; applications, do not use all that is in a new bag at one time. For best; REFERENCE; Glowing Embers
31 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. READ WARNINGS ON THIS PAGE BEFORE PROCEEDING. FOLLOW THE LOG PLACEMENT INSTRUCTIONS EXACTLY 1. Remove the front glass enclosure panel (see Glass Enclosure Panel Removal and Installation Instructions , Page 34 ) . 2. Remove the following from fi...
Page 32 - EDVPF, EDVST, EDVCL AND EDVCR LOG PLACEMENT; Log
32 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. EDVPF, EDVST, EDVCL AND EDVCR LOG PLACEMENT Figure 61 Catalog Number for the entire log set: 55M04 Log Part Number Description Number 1 Log, Corner 55M18 2 Log, Rear/Left 55M19 3 Log, Front/Left 55M20 4 Log, Rear/Right 55M21 5 Log, Front/Center...
Page 35 - achieved; Burner Flame Appearance
35 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNINGS • Air shutter adjustment should only be performed by a quali- fied professional service tech- nician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Soot will be produced if the air shutter is closed t...
Page 36 - Step 12. HOOD INSTALLATION; Refer to Figure 66. All of these appliances; FINISHING REQUIREMENTS; Complete finished interior wall. To install the; See Page 5 for
36 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Combustible Wall Framing Combustible Finished Wall Materials Drywall Bracket/Spacer Top of Appliance Louvers Top of Door Frame Hood must be installed as shown. Figure 66 - FINISHING REQUIREMENTS 1 in. Min. (25 mm) This Area Must Remain Clear of...
Page 37 - Figure A
37 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. STEP 13. ATTACHING SAFETY-IN-OPERATION WARNINGSIt is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this appl...
Page 38 - rigid; INSTALLATION ACCESSORIES; Listed Secure VentTM Components
38 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Cat. No. Model Description 77L70 SV4.5L6 6 Inch (152 mm) 77L71 SV4.5L12 12 Inch (305 mm) 77L72 SV4.5L24 24 Inch (610 mm) 77L73 SV4.5L36 36 Inch (914 mm) 77L74 SV4.5L48 48 Inch (1219 mm) 77L75 SV4.5LA Telescopic Length Slip Sec- tion (2" to ...
Page 39 - INSTALLATION ACCESSORIES CONTINUED
39 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. H1969 SF4.5HT-2 Horizontal Square Termina- tion for flex (without flex) 77L87 SFKIT12S Square Term. for flex (with 12 inch [305 mm] * compressed flex) 77L88 SFKIT18S Square Term. for flex (with 18 inch [457 mm] * compressed flex) 77L89 SFKIT24S...
Page 40 - this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.
40 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. In Canada: THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN/CSA-B149.1 INSTALLATION CODE. LA CONVERSION DEVRA êTRE EFFEC...
Page 41 - All Models; Note: If the ignitor is damaged, a replacement kit; Electronic Appliances
41 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. d. Locate the two (2) latches at the top of the control compartment. To disengage the two latches from the bottom vee-flange of the glass enclosure panel, reach for the handles located towards the back of the latches and pull the handles down t...
Page 42 - BURNER POSITIONING; PAN; Table 9